background image

24

USER ASSISTANCE

Atlantic Ultraviolet Corporation

®

 

makes every effort to ensure that the 

SANITRON

®

 

/ MIGHTY

«

PURE

®

 

Ultraviolet Water Purifiers is a product 

of superior quality and workmanship. 

This manual describes the installation, 

operation and maintenance of the 

SANITRON

®

 

/ MIGHTY

«

PURE

®

.

Please read and become familiar with the 

contents of this manual before installing 

or using this unit. If after reading the 

manual you still have questions, or 

concerns, regarding the installation or 

use of this unit, contact our offices, 

weekdays between 8:30 am and 5:00 pm 

Eastern Time, at:

Atlantic Ultraviolet Corporation

®

375 Marcus Boulevard

Hauppauge, New York, 11788
Tel: 631.273.0500

Fax: 631.273.0771

E-mail: [email protected]

Website: Ultraviolet.com

 

BuyUltraviolet.com

PRODUCT REGISTRATION

Please REGISTER your product immediately - you can do this in a number of ways. Go online to Ultraviolet.com  and on the 

bottom left of each page either click on “Fill out Warranty Reg. Form on-line!” complete and hit submit or click on “Download 

a PDF of the Warranty Reg. card” which you can print, fill out and mail in. If you prefer to register over the telephone please call 

631-273-0500.
Atlantic Ultraviolet Corporation

®

 takes all possible precautions when packaging equipment to prevent damage. Carefully inspect 

and report all damage. Do not install damaged equipment. Follow all instructions on any labels or tags. Carefully inspect all 

packing materials before discarding to prevent the loss of accessories, mounting hardware, spare parts or instructions.

For your convenience, record the following information below. The model and serial number can be found on a label located on 

the 

SANITRON

®

 

/ MIGHTY

«

PURE

®

 

Ultraviolet Water Purifier. Keep this manual, along with proof of purchase, handy when 

contacting our offices.

Purchased From:

Date:

Model:

Serial No.:

WARRANTY

We warrant that this product will be free from defects in material and workmanship for a period of one year from the date of 

shipment thereof or the product’s total rated life, whichever first occurs. Within the warranty period we shall repair or replace such 

products, which are returned to us with shipping charges prepaid, and which are determined by us to be defective. This warranty 

will not apply to any product, which has been subjected to misuse, negligence, or accident; or misapplied; or modified; or repaired 

by unauthorized persons; or improperly installed.
The Buyer shall inspect the product promptly after receipt and shall notify us at our main office in writing of claims, including 

claims of breach of warranty, within thirty (30) days after the Buyer discovers or should have discovered the facts upon which 

 

the claim is based. Failure of the Buyer to give written notice of a claim within the time period shall be deemed to be a waiver 

 

of such claim.
The provisions of the above warranty are our sole obligation and exclude all other remedies or warranties, expressed or implied, 

including warranties of merchantability and fitness for a particular purpose, whether or not purposes or specifications are 

described herein. We further disclaim any responsibility whatsoever to the customer, or to any person, for injury to person, 

damage to, or loss of property or value caused by any product which has been subjected to misuse, negligence, accident; or 

modified or repaired by unauthorized persons; or improperly installed.

Under no circumstances shall the Atlantic Ultraviolet Corporation

®

 be liable for any incidental, consequential or special damages, 

losses or expenses arising from the contract for this product, or in connection with the use of, or inability to use, our product for 

any purpose whatsoever.

P

atent

 n

otiCe

No attempt has been made to determine the patent status of applications illustrated or described in this publication. Inclusion 

in this publication of any design or method of use, which may be patented, is not to be construed as promoting or sanctioning 

unauthorized use.

Summary of Contents for Mighty Pure MP36C

Page 1: ... THE USA Installation Operation Maintenance Read and Follow All Safety Instructions Save These Instructions Models Sanitron S37C Mighty Pure MP36C Designed for CE Compliance ULTRAVIOLET WATER PURIFIERS ULTRAVIOLET WATER PURIFIERS Extensive Product Information Available at ultraviolet com buyultraviolet com ...

Page 2: ...2 MAINTENANCE NOTES 23 USER ASSISTANCE PRODUCT REGISTRATION 24 WARRANTY 24 Patent Notice 24 These instructions generally describe the installation operation and maintenance of the CE Compliant water purifiers MIGHTY PURE Model MP36C and SANITRON Model S37C Questions that are not specifically answered by these instructions should be directed to the Factory Atlantic Ultraviolet Corporation takes all...

Page 3: ... POTENTIALLY hazardous situation which if not avoided COULD result in death or serious injury This symbol pictorial is used to identify the need to wear approved ultraviolet blocking eyewear This symbol pictorial is used to identify the need to wear approved ultraviolet blocking face shield This symbol pictorial is used to identify components which must not be disposed of in trash Danger indicates...

Page 4: ...flow rate the lower the exposure time or the lower the flow rate the higher the exposure time The ultraviolet intensity is the amount of energy per unit time emitted by the germicidal lamp The dosage is the product of ultraviolet intensity and the exposure time The operation of the SANITRON MIGHTY PURE is as follows Water enters the purifier and flows into the annular space between the quartz slee...

Page 5: ... of use This reduces the chance of the purified water being re contaminated by bacteria in the water distribution system after the water purifier 6 As with any water handling device the water purifier should be located in an area where any possible condensation or leakage from the water purifier any purifier accessory and or plumbing will not result in damage to the area surrounding the water puri...

Page 6: ...talled on both the inlet and outlet sides of the water purifier The use of bypass valves is not recommended The shut off valves allow the purifier to be isolated from the water supply which is required when removing the quartz sleeve 7 Unions should be installed on both the inlet and outlet of the water purifier this will allow easy removal of the water purifier from the plumbing if required Apply...

Page 7: ...SureFLO Flow Control Valve Limits water flow to the rated capacity of the purifier The flow control valve is located in line prior to the water purifier and should be protected from ultraviolet exposure by the use of a 90 degree elbow fitting between the flow control valve and the water purifier 5 Promate Audio Alarm Activated by the Ultraviolet Monitor or Safety Sensor alerts the user to any malf...

Page 8: ...ing Contact factory with questions Inspection 1 Regularly inspect the water purifier to ensure that the germicidal lamp is still in operation On purifiers not equipped with the Ultraviolet Monitor lamp operation can be verified by a visible glow through the translucent sight port This provides an indication of lamp operation and does not indicate the level of ultraviolet intensity or transmission ...

Page 9: ...Next carefully slide lamp back into chamber until approximately 2 inches of the lamp is exposed on the opposite end Hold lamp and remove lamp socket 6 Lamp should now be disconnected on both ends Carefully remove lamp from chamber Be sure to withdraw lamp straight out without angling until completely clear of quartz sleeve Lamp and quartz sleeve are easily damaged Exercise care when handling 7 Rei...

Page 10: ...uartz sleeve is easily accomplished using the dual action wiper mechanism 1 Lift wiper clip up and away from wiper rod 2 Grasp wiper knob and gently pull out away from the purifier until it reaches its stop 3 Push wiper back in toward the purifier until it reaches its second stop 4 Repeat steps 2 and 3 as necessary 5 Holding wiper in place return wiper clip and snap over wiper rod in front of the ...

Page 11: ...es remain within the static gland nut If so remove Teflon washer from static gland nut before proceeding 6 Carefully remove quartz sleeve from chamber NOTE It is advisable to support the quartz sleeve on the opposite end with your finger so that it does not drop to the bottom of the chamber as it slides into the chamber 7 Once the quartz sleeve is removed clean with alcohol or a mild non abrasive ...

Page 12: ...through the gland fitting Flush water through chamber being careful to remove all quartz fragments from the interior of the chamber 5 Carefully discard all pieces of the broken quartz sleeve 6 Align the end of the replacement quartz sleeve with the gland fitting of the chamber 7 Carefully slide the quartz sleeve into the chamber guiding it through the gland fitting NOTE Use care to keep the quartz...

Page 13: ... nut from the head clamp 4 Withdraw chamber head and wiper assembly from the chamber 5 Any broken pieces of the quartz sleeve can now be removed through the open end of the purifier chamber Flush water through chamber being careful to remove all quartz fragments from the interior of the chamber 6 Carefully discard all pieces of the broken quartz sleeve 7 Inspect the large O Ring used to seal the c...

Page 14: ...nd outlet shut off valves Remove drain plug and drain the chamber Once the chamber is drained remove any old sealing tape from the threads of the drain plug rewrap with 1 2 wide Teflon thread sealing tape reinstall and tighten the drain plug 3 Disconnect power to the Ultraviolet Monitor remove from chamber by loosening the two set screws on the aluminum collar and lifting it free from probe body 4...

Page 15: ...in and remove static gland nut replace sealing O Ring See Quartz Sleeve Installation or Replacement in the Maintenance section Poor or loose connections or fittings Tighten suspect connection or fitting or shut down purifier drain and remove fitting or connection Clean threads reapply thread sealing tape and reinstall Poor purifier disinfection performance AND OR Low UV intensity As indicated on o...

Page 16: ...60Hz Length 37 3 8 50 3 8 Width 5 11 16 5 11 16 Height 9 1 2 9 1 2 Chamber Diameter 4 1 4 4 1 4 Lamp Model No 05 1343 R 05 1343 R Ultraviolet Output 15 Watts 15 Watts Lamp Watts k 41 Watts 41 Watts Rated Life of UV Lamp 10 000 Hrs 10 000 Hrs All specifications dimensional data etc are approximate and subject to change without notice M M Ultraviolet output at 254nm at 100 hours and 80 F approximate...

Page 17: ...17 Mighty Pure Model MP36C Figure 9 Exploded View MP36C ...

Page 18: ... 1 15 1113A 9 Sight Port Plug 1 30 1075 10 Chamber 1 25 1465G4 11 Drain Plug 1 27 1216 12 Screw 1 4 20 x 3 8 Long 4 50 1034 13 Lock Washer 1 4 4 50 1321 14 Flat Washer 1 4 4 50 1317 15 Ballast Housing Cover 1 25 0394A 16 Screw No 8 x 3 8 Long 8 50 1323 17 Speed Nut 6 32 2 50 1314 18 Surelite Ballast Elect 230V 10 1 10 0115 19 Ferrite EMI Suppression 2 35 1749 20 Ballast Housing 1 25 1164A 21 Screw...

Page 19: ...19 SANITRON Model S37C Figure 10 Exploded View S37C ...

Page 20: ...1 16 Wiper Knob 1 25 1222 17 Wiper Lock Spacer 1 25 1512A1 18 Wiper Clip 1 25 1507C1 19 Dynamic Gland Wiper Lock 1 25 1510C1 20 Drain Plug 1 27 1216 21 Screw 1 4 20 x 3 8 Long 4 50 1034 22 Lock Washer 1 4 4 50 1321 23 Flat Washer 1 4 4 50 1317 24 Ballast Housing Cover 1 25 0394A 25 Screw No 8 x 3 8 Long 8 50 1323 26 Speed Nut 6 32 2 50 1314 27 Surelite Ballast Elect 230V 10 1 10 0115 28 Ferrite EM...

Page 21: ...21 ...

Page 22: ...22 ...

Page 23: ...23 MAINTENANCE NOTES ...

Page 24: ...t will be free from defects in material and workmanship for a period of one year from the date of shipment thereof or the product s total rated life whichever first occurs Within the warranty period we shall repair or replace such products which are returned to us with shipping charges prepaid and which are determined by us to be defective This warranty will not apply to any product which has been...

Reviews: