REPLACEMENT PARTS

LIND 24-EVO

Figure 3 - Replacement parts Model LIND 24-EVO

Other replacement parts are available. Consult the Factory for specific requirements.

Item No.:

Description:

Quantity:

Part No.

1

Germicidal Ultraviolet Lamp, G24T6L

1

05-1348

Electronic Variable Output Ballast, 120v 50/60Hz

10-0056B

2

Electronic Variable Output Ballast, 220-240v 50/60Hz

1

10-0055B

3

Lamp Holder Set

1

05-1320A

4

Safety Interlock Switch

1

35-0008A

5

Thumbscrew, 8-32 x 3/8" Lg

2

50-0080

6

Plug, ½" ID

1

00-0027

Summary of Contents for Hygeaire Air Disinfection

Page 1: ...vised September 2007 2003 2007 Atlantic Ultraviolet Corporation ultraviolet com 375 Marcus Boulevard Hauppauge NY 11788 USA 631 273 0500 Fax 631 273 0771 e mail info ultraviolet com Extensive Product...

Page 2: ...ASSISTANCE 12 WARRANTY 12 PATENT NOTICE 12 These instructions generally describe the installation operation and maintenance of the Hygeaire line of Indirect Ultraviolet Room Air Sanitizers Models LIND...

Page 3: ...rdous situation which if not avoided COULD result in death or serious injury Caution indicates a POTENTIALLY hazardous situation which if not avoided MAY result in minor or moderate injury Caution use...

Page 4: ...s should be implemented to prevent accidental exposure of personnel who might enter the irradiated space Electricians and other trades people in particular All work performed painting new ceil ings eq...

Page 5: ...s designed to mount horizontally on a vertical surface or wall approximately 6 to 7 feet above the floor The Hygeaire LIND 24 EVO 2PM fixture includes pendant hardware to suspend fixture from the ceil...

Page 6: ...and reflectors 3 Remove one mounting screw from each end of the reflector so that the reflector will be able to pivot toward the lamp holder 4 Pivot reflectors on remaining screws to expose the rear m...

Page 7: ...AUTIONS Immediately following initial installation of the Hygeaire fixture the occupied area of the room should be surveyed with the ZenithTM Ultraviolet Meter to insure that the ultraviolet radiant e...

Page 8: ...utput of the Hygeaire fixture must be adjusted The electronic variable output ballast controls germicidal ultraviolet lamp output The remote potentiometer used for output adjustment is recessed in the...

Page 9: ...operly seated connection is tight and lamp holder is making full contact with lamp Germicidal lamp faulty Swap suspect lamp with lamp known to be good If suspect lamp does not operate replace lamp Bal...

Page 10: ...fic requirements Item No Description Quantity Part No 1 Germicidal Ultraviolet Lamp G24T6L 1 05 1348 Electronic Variable Output Ballast 120v 50 60Hz 10 0056B 2 Electronic Variable Output Ballast 220 2...

Page 11: ...tion Quantity Part No 1 Germicidal Ultraviolet Lamp G24T6L 2 05 1348 Electronic Variable Output Ballast 120v 50 60Hz 10 0056B 2 Electronic Variable Output Ballast 220 240v 50 60Hz 2 10 0055B 3 Lamp Ho...

Page 12: ...ility to use our product for any purpose whatsoever PATENT NOTICE No attempt has been made to determine the patent status of applications illustrated or described in this publi cation Inclusion in thi...

Reviews: