O p e r a t i n g   I n s t r u c t i o n s

 

BKI 109 e 

4100-001-04/12 

Department 

 

Electronically controlled lubricators  

125 cm

3

 – battery-operated 

applicable to 65 91 006

 

Page 

Rev. Index 

 

Name 

Schell 

18.04.12 

Date 

 

released 

Reichert 

18.04.12 

 

BKI 109 engl.DOC 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Setting time in 
months 

12 

18 

DIP switch 

Pressure build-
up time in days 

10 

14 

Pressure build-up times: 
The batteries need a certain time to build up the 
pressure. They induce an electro-pneumatic reaction  
in the built-in nitrogen chamber and transmit the 
pressure to the piston via a bellows. This chamber 
has to be replaced at the end of the lubricating time. 

 

Simply set the desired operating time and mount it. 
The resulting pressure build-up times are then as 
follows:

 

Lubrication starts after the appropriate pressure 
build-up. The pressure remains built-up even if the 
lubricator is switched off for some time. 
Therefore lubrication begins immediately after 
switching on the lubricator again because the 
pressure remains built-up. 
 
Immediate lubrication and safety check 
Set all switches to the "on" position. Pressure build-
up time approx. 6 – 8 hours. Then reset all switches 
and set the desired operating time. The signal light 
blinks. 
 
Visual control of the pressure build-up by marking the  
filling state at the transparent housing. Depending 
upon the dosage chosen the piston in the lube 
dispenser should move downward from the marking 
for more or less time during the pressure build-up. 
 

Important information! 

Ambient temperature max. -20°C to max. +50°C. 
Avoid electrostatic charging of the lube dispenser 
(e.g. due to friction with cloth or strong air currents). 

Setting combinations for lube dispenser 

DIP switch 
position 

Daily amount of 
lubricant 

Lubricating time  
of lubricator 

7  = switch for  „ON“ -  signal light blinks at short intervals 

6 = 18 M 

0.175 cm

3

 

18 months 

5 = 12 M 

0.35   cm

3

 

12 months 

4 =   6 M 

0.70   cm

3

 

  6 months 

3 =   3 M 

1.30   cm

3

 

  3 months 

2 =   2 M 

2.10   cm

3

 

  2 months 

1 =   1 M 

4.00   cm

3

 

  1 month 

All switches  
activated 

9.00   cm

3

 

14 days 

Combinations: 
5 + 4 

1.05 cm

3

 

121    days 

5 + 3 

1.74 cm

3

 

  71    days 

4 + 3 

2.08 cm

3

 

  57    days 

5 + 4 + 3 

2.35 cm

3

 

  52    days 

5 + 2 

2.45 cm

3

 

  51    days  

4 + 2 

2.60 cm

3

 

  45    days 

3 + 2 

3.48 cm

3

 

  35    days 

5 + 3 + 2 

3.83cm

3

 

  30    days 

4 + 3 + 2 

4.16 cm

3

 

  28    days 

5 + 4 + 3 + 2 

4.53 cm

3

 

  27    days 

4 + 1 

4.80 cm

3

 

  24    days 

3 + 1 

5.56 cm

3

 

  23,5 days 

2 + 1 

6.26 cm

3

 

  20    days 

5 + 2 + 1 

6.61 cm

3

 

  19    days 

3 + 2 + 1 

7.65 cm

3

 

  17    days 

5 + 3 + 2 + 1 

8.00 cm

3

 

  16    days 

4 + 3 + 2 + 1 

8.33 cm

3

 

  15    days 

5+4+3+2+1 

8.70 cm

3

 

  14.5 days 

 

Technical tips: 
Extension with hose or tube is possible up to 
approx. 1.5 m for grease lubrication and 5 m 
with oil lubrication. In this case the lubrication 
charts do not apply because the viscosity of the 
lubricant and the length of the hose influence 
the flow behaviour of the lubricant.  Mind the 
correction factors on page 3. There is less 
resistance in case of oil filling; therefore we 
recommend to use a check valve with 0.2 bars. 
The lube dispenser lubricates constantly, i.e. 
no impulse lubrication.

 

Technical data: 

Supply voltage (2 x 1.5V) 3V 
BSV 03 ATEX E 223 
Standard type: Varta Electric Power 8008 for 
Groups I and IIC T 3 
Special type: Varta Industrial Mignon / AA for 
Groups I and IIC T 4 
 
II 2G EEx ib IIC T4/T3 Gb 
I M2 EEx ib I Mb 

 