![Atlanta Attachment Company 1392D Technical Manual & Parts Lists Download Page 62](http://html.mh-extra.com/html/atlanta-attachment-company/1392d/1392d_technical-manual-and-parts-lists_2999655062.webp)
Technical Manual & Parts Lists
55
NOTE: If Slow Speed is set to a value higher that Fast Speed then Slow Speed is automatically
changed to equal the Fast Speed. Therefore, Slow Speed can never exceed Fast Speed.
Limits: Minimum - 0 Maximum - 10 Default - 5
Unit of Measure - RPM
Thread Break Enable Delay
When the machine is not running the Thread Break eyes are dark as in an actual Thread Break condition.
When the machine starts running, it takes a few seconds for the thread detection devices to report
properly. This setting delays when the Needle and Looper Thread Breaks become active.
Limits: Minimum - 0 Maximum - 5.0 Default - 1.0
Unit of Measure - Seconds
Thread Break Debounce
When the machine is not running the Thread Break eyes are dark as in an actual Thread Break condition.
Therefore, Needle and Looper Thread Breaks are not active until the machine has been running for the
time set by the Thread Break Enable Delay setting. During the process of sewing the needle and looper
thread may loosen or tighten causing the Thread Break Detect eyes to go dark. The Thread Break
Debounce gives the thread time to "settle down" in order to report an actual thread break. If this number
is set too low you may get false thread break errors. Conversely, if set to high, several stitches may pass
before the operator is alerted.
Limits: Minimum - 0 Maximum - 5.0 Default - 1.0
Unit of Measure - Seconds
Undertrimmer Delay
The Undertrimmer is the knife mechanism under the needle plate that trims the needle thread when
needed. The Undertrimmer activates during a jump move in a Sew and Jump pattern. During the jump
portion of a Sew and Jump pattern, the machine stops after it has moved the Needle Tail Length
distance. The machine then stops to allow for the Undertrimmer to activate. The Undertrimmer Delay is
the amount of time the jump move is delayed to allow the Undertrimmer to cut the needle thread. Once
undertrimming is complete the machine continues the jump move.
Limits: Minimum - 1.00 Maximum - 4.00 Default - 2.00
Unit of Measure - Seconds
Foot Height High Limit
The maximum RPM allowed with the foot in the High position.
Limits:
Minimum - 0
Maximum
- 1275
Default - 500
Unit of Measure - RPM
Summary of Contents for 1392D
Page 2: ......
Page 40: ...Technical Manual Parts Lists 33 3 Route the thread from the rod down to the eyelets below ...
Page 72: ...Technical Manual Parts Lists 65 ...
Page 76: ...Technical Manual Parts Lists 69 ...
Page 78: ...Technical Manual Parts Lists 71 ...
Page 82: ...Technical Manual Parts Lists 75 ...
Page 84: ...Technical Manual Parts Lists 77 ...
Page 92: ...Technical Manual Parts Lists 85 ...
Page 94: ...Technical Manual Parts Lists 87 ...
Page 96: ...Technical Manual Parts Lists 89 ...
Page 100: ...Technical Manual Parts Lists 93 ...
Page 122: ...Technical Manual Parts Lists 115 ...
Page 124: ...Technical Manual Parts Lists 117 ...
Page 126: ...Technical Manual Parts Lists 119 ...
Page 136: ...Technical Manual Parts Lists 129 ...
Page 144: ...Technical Manual Parts Lists 137 ...
Page 153: ...Technical Manual Parts Lists 146 ...
Page 155: ...Technical Manual Parts Lists 148 ...
Page 156: ...Technical Manual Parts Lists 149 1392C PD Pneumatic Diagram 125487B ...
Page 157: ...Technical Manual Parts Lists 150 1392 WD1 Cabinet Wiring Diagram 125349A ...
Page 158: ...Technical Manual Parts Lists 151 1392 WD2 Quilter Panel Wiring Diagram 125370A ...
Page 159: ...Technical Manual Parts Lists 152 ...