Atkinson Electronics GSCM-MINI-D Quick Manual Download Page 8

GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire) 

GSCM-MINI-D

ATKINSON ELECTRONICS, INC.

REV 07/08

Web Site: www.atkinsonelectronics.com

Distributed by:

APPLICATION 2 - REMOTE RV GENERATOR START CONSOLE REPLACEMENT

The GSCM-mini-d can be used
to replace a typical remote
generator control console, that
is  mounted on the dash of  a
motorhome. Instead of a large
console and cable, use a small
16  to 18 gauge 4 wire signal
cable, an on-off switch with built
in  light and a separate 12vdc
fault light.  When the remote
switch is turned on, the GSCM-
mini-d  starts the generator.
After the generator starts and
comes up to speed the “run”
LED  lights on the GSCM mini
and lights  the remote start
switch light. If the generator fails
to 

start or fails while

commanded to run the “fault”
LED on the GSCM- mini-d lights
along with the remote fault
12vdc  light.  Turning off the
power to the GSCM mini resets
the fault condition and it is ready
to receive another start
command. 

APPLICATION 3 - GenMate PC BOARD REPLACEMENT

The GSCM-mini-d can be used to
replace a GenMate PC Board, that
is mounted on the upper console
of a motor coach. The GSCM-mini-
D uses the same 6 wires that the
GenMate used to start and stop the
diesel generator based on battery
voltage.  When the coach battery
voltage falls below 11.5vdc the
GSCM-mini-D starts the generator
to charge the batteries. When the
batteries 

reach 13.8vdc the

GSCM-mini-D shut down the
generator.  An optional manual
start switch can be added to
manually start the generator for
other uses.  A power/reset switch
is recommended to reset any fault
conditions  and to shutdown the
auto start when generator is being
serviced.  For 24v systems the
GSCM-mini-D must be power from
12vdc and the battery sense input
(terminal 4) would wire directly to
the positive of the 24v battery bank.

Summary of Contents for GSCM-MINI-D

Page 1: ...Section 1 for operation description Maintained Start Contact Option 2 terminal 6 is grounded The GSCM mini D changes to a maintained start operation for generators that use a maintained closed contac...

Page 2: ...RATOR START CONTROL MODULE MINI 2 Wire to 3 Wire GSCM MINI D ATKINSON ELECTRONICS INC REV 07 08 Web Site www atkinsonelectronics com Distributed by GSCM mini D WIRING DIAGRAM AND CONTROLLER CONFIGURAT...

Page 3: ...wired and installed by the user stops requiring a maintained start signal The K2 relay provides a the generator instantly in emergency situations such as a fuel momentary stop signal until the genera...

Page 4: ...fuel problem etc the start sequence will revert to the Ready mode after a 60 second delay During this delay the start LED will blink rapidly The GSCM mini D will then try to start the generator again...

Page 5: ...remains closed until either the generator starts or the maximum cranking time period 20 seconds is reached 2 If the generator fails to start after the 20 seconds cranking period K1 relay opens for a...

Page 6: ...RTING FOR BATTERY CHARGING SECTION 6 The GSCM mini D can monitor either the generator battery voltage or a battery bank voltage and Automatically start stop the generator based on battery voltage This...

Page 7: ...elay after start signal removed before generator started 2 Generator Hz fast blink over speed condition Shutdown slow blink under speed condition double blink Maximum Crank attempts reached Failed to...

Page 8: ...long with the remote fault 12vdc light Turning off the power to the GSCM mini resets the fault condition and it is ready to receive another start command APPLICATION 3 GenMate PC BOARD REPLACEMENT The...

Page 9: ...ch appear within two 2 years from the date of shipment by Atkinson Electronics Inc or its authorized distributors to the original Customer Atkinson Electronics Inc will repair or replace at our option...

Reviews: