Atkinson Electronics A0217 Manual Download Page 16

www.atkinsonelectronics.com 

             Circuit Board Division 

800.261.3602 

16 

Revised 09/18

 

 

GSCM Limited Warranty 

 

Atkinson Electronics, Inc. gives this express warranty (along with extended warranty endorsements, where applicable) in lieu of 
all other warranties, express or implied, including (without limitation), warranties of merchantability and fitness for a particular 
purpose. This constitutes Atkinson Electronics, Inc.'s sole warranty and obligation with regard to our products as well as the 
Customer's sole remedy. 
Atkinson Electronics, Inc. expressly disclaims all liability and responsibility for any special, indirect or consequential damages or 
any further loss of any kind whatsoever resulting from the use of our product. The Customer's sole and exclusive remedy and 
the limit of Atkinson Electronics, Inc.'s liability for any loss whatsoever, shall not exceed the purchase price paid by the Customer 
for the product to which a claim is made. 
Countries or States that do not allow limitations of incidental or consequential damages or on how long an implied warranty 
lasts, the above limitations may not apply to you. This warranty gives you specific legal rights and you may also have other rights 
which vary from State to State or Country to Country. 
All products manufactured by Atkinson Electronics, Inc. are warranted to be free from defects in material and workmanship in 
accordance with and subject to the following terms and conditions: 
 

1.

 

This warranty is limited to the original customer only.  It cannot be transferred or assigned to third parties unless the 
intent to transfer to a third party is expressly indicated in a purchase order and/ or warranty processing arrangements 
have been agreed upon in writing by Atkinson Electronics, Inc. 

2.

 

Atkinson Electronics, Inc. will correct any defects in material or workmanship which appear within two (2) years from 
the date of shipment by Atkinson Electronics, Inc. (or its authorized distributors) to the original Customer.  Atkinson 
Electronics, Inc. will repair or replace, at our option, any defective products, provided that our inspection discloses that 
such defects developed under normal and proper use.  This warranty does not extend to goods subjected to misuse, 
neglect, accident or improper installation, or to maintenance or repair of products which have been altered or repaired 
by anyone except Atkinson Electronics, Inc., unless otherwise stated in writing.  Atkinson Electronics, Inc. will correct 
any defects in material or workmanship of OEM products (designated as such in our catalog or web site) which appear 
within two (2) years from the product date code or from the factory invoice date, whichever is later. 

3.

 

An appropriate charge (25% of product list price) may be made for testing, repairs, replacement and shipping for a 
returned product which is not defective or found to be defective as the result of improper use, maintenance or neglect. 

4.

 

Atkinson Electronics, Inc. will not accept responsibility for any invoiced goods or services that are not covered by an 
Atkinson Electronics, Inc. written purchase order.  Under no circumstances does Atkinson Electronics, Inc. agree to pay 
for labor or other related expenses associated with the troubleshooting and/ or repair of our product without prior 
specific written authorization. 

5.

 

 Information in our descriptive literature is based on product specifications that are current at the time of publication. 

Product specifications, design and descriptive literature are subject to change as improvements are introduced.  Although we 
announce changes as they occur, we cannot guarantee notification to every Customer.  Atkinson Electronics, Inc. warrants 
delivered products to conform to the most current specifications, design and descriptive literature.  This warranty policy may 
be expanded or limited, for particular categories of products or Customers, by information sheets published as deemed 
appropriate by Atkinson Electronics, Inc. 

Summary of Contents for A0217

Page 1: ...Generator Start Control Module Part GSCM Rev C Code Version 5 13 ATKINSON ELECTRONICS INC 14 West Vine Street Murray Utah 84107 ...

Page 2: ... not already running before trying to start a second or third time Features Applications Automatic starting load transfer and shutdown for gas and diesel generators Off grid generators Automatic adjustable voltage set points for generator battery charging applications 0 60VDC Works with 12 24 or 48V battery systems Provides fault shutdown for low oil pressure high temperature and under speed or ov...

Page 3: ...e is set at 0 de activated The GSCM provides a 30 day exercise function which can be synchronized with a photo voltaic input to only start each 30 day period at the beginning of the solar charge day A user supplied DC relay can be energized during the 30 day generator exercise to override a battery charger and allow the battery bank to equalize by charging the batteries above the normal charger cu...

Page 4: ...www atkinsonelectronics com Circuit Board Division 800 261 3602 4 Revised 09 18 GSCM Wiring Diagram ...

Page 5: ...e maximum crank lockout condition This lockout condition remains until the GSCM is reset by momentarily shorting the reset terminals 7 and 8 together after which the start LED blinks for 60 seconds and then enters ready mode Powering down the GSCM for 5 seconds and powering it back up will also clear the maximum crank lockout condition with the GSCM returning to ready mode 6 When the generator sta...

Page 6: ...ins 7 and 8 momentarily The open collector transistor terminal 18 will energize a user supplied DC relay not exceeding 180 milliamp coil current whenever a fault shutdown occurs and will de energize the relay when the fault is reset The shutdown conditions are as follows 1 Failure to start with 4 cranking attempts See GSCM STARTING SEQUENCE section 4 5 The max crank max runtime fault LED blinks ra...

Page 7: ... will shut down the generator and indicate a maximum runtime fault by slowly blinking the max crank max runtime LED See GSCM SHUTDOWN CONDITIONS section 6 This runtime fault is only active in the automatic starting mode 6 The GSCM will clear the max runtime fault if the reset terminals 7 8 are momentarily shorted a manual start signal is applied to terminals 5 6 or a period of 12 hours passes from...

Page 8: ...e to 0VDC store setting advance to high Hz position and set to zero volts both must be set 9 To re enable the 5 and 10 minute time delays the GSCM must enter adjustment mode as in paragraph 1 of this section and then the cut in and cut out adjustment re entered and stored without the jumper between terminals 15 and 16 Restoring the GSCM factory default values as described in GSCM Reset Conditions ...

Page 9: ...ad transfer 0 120 Second Load Pre Off Blinking load disconnected cool down period before shutdown Battery Charge Cut In x12 Blinking battery voltage lower than cut in point during 5 minute delay Battery Charge Cut Out x12 Blinking battery voltage greater than cut out point during 10 minute delay 15 75Hz Under Hz Shutdown Blinking generator Hz under speed less than trip point during 10 second delay...

Page 10: ...rank Delay 5 second minimum 60 seconds Maximum crank time Will not energize starter 60 seconds Load transfer delay Ignition and load relays energize together 60 seconds Load pre off delay Ignition and load relays de energize together 120 seconds Battery charge cut in Ignores automatic battery charge function Switched auto start Battery charge cut out Ignores automatic battery charge function Switc...

Page 11: ...e generator has reached 30Hz or half speed If this setting doesn t allow the start input to remain engaged long enough for the generator to stay on line adjust the run disconnect setting to 55Hz See GSCM INITALIZATON AND ADJUSTMENT for changing adjustments The K4 shutdown relay provides a momentary stop signal until the generator AC Hz has dropped to zero The K3 ignition relay provides a continuou...

Page 12: ...rations are shown for both automotive and magneto type with or without fuel valves High speed 3600 RPM generators may need the crank disconnect hertz adjustment set to 20Hz or less to avoid over driving the starter Low Speed Gas Propane Generator with Safeties The low speed gas propane generators also wire the same as in application 2 However the installer should determine ignition type and oil an...

Page 13: ...ession solenoid furnished with the generator must be wired to K4 shutdown relay to energize on shutdown Automatic Generator Powered AC Pump In this application the GSCM is connected to a pressure or level switch into the battery sense terminals To make the appropriate cut in and cut out adjustments See AUTOMATIC STARTING FOR BATTERY CHARGING section 9 The cut in and cut out adjustments must be set...

Page 14: ...a special low voltage generator frequency input version for 12V alternator applications GSCM 12V ALT 255 Hz See AUTOMATIC STARTING FOR BATTERY CHARGING section 9 4 9 Generator Powered Air Conditioner The room thermostat should be line voltage slow action type to minimize short cycling signals the generator to start The GSCM K5 load transfer relay starts the air conditioner after the generator is r...

Page 15: ...ter the GSCM starts the generator with a 3 wire start stop or any other generator starting application to match the type of generator to be controlled If the user desires the voltage from the generator s battery may be connected to the GSCM on terminal 4 and the GSCM will start the generator automatically to charge its own battery when the voltage falls below the battery cut in threshold voltage T...

Page 16: ...m the date of shipment by Atkinson Electronics Inc or its authorized distributors to the original Customer Atkinson Electronics Inc will repair or replace at our option any defective products provided that our inspection discloses that such defects developed under normal and proper use This warranty does not extend to goods subjected to misuse neglect accident or improper installation or to mainte...

Reviews: