Problem Possible
cause
Remedy
Logs are not being split properly
(insufficient splitting
performance).
⇒
The log is not positioned correctly.
⇒
The log exceeds the maximum
dimensions or the wood is too hard for
the performance of the machine.
⇒
Splitting blade does not split log.
⇒
Hydraulic pressure too low.
⇒
Release rods bent (hydraulic tappet not
quite pressed in).
⇒
Incorrect connecting lead (longer than
10 m or too small cable cross-section).
⇒
Reposition the log correctly.
⇒
Cut the log to the required dimensions.
⇒
Sharpen splitting blade, check for burrs or
notches.
⇒
Check the oil level and add more oil if
necessary.
If the problem cannot be rectified, refer to the
manufacturer or other approved service centre.
⇒
Arrange for manufacturer or authorised
company to adjust the rods.
⇒
Use the correct connecting lead.
Splitting column moves
unsteadily or with strong
vibrations.
⇒
Air in the circuit.
⇒
Splitting column not sufficiently
lubricated or oiled.
⇒
Check the oil level and add more oil if
necessary.
⇒
Lubricate splitting column or oil with
environmentally friendly spray oil.
If the problem cannot be rectified, refer to the
manufacturer or other approved service centre.
Splitting column does not move
in.
⇒
Hydraulic pump defective.
⇒
To correct the problem, refer to the
manufacturer or other approved service centre.
Motor starts, but splitting column
does not move in.
⇒
Motor turns in wrong direction
⇒
Check the motor direction
Threephase: adjust the motor direction
(s. page 19)
AC: To correct the problem, refer to the manu-
facturer or other approved service centre.
Motor will not start.
⇒
No electrical power.
⇒
2-phase mode in threephase motor.
⇒
Connection cable defective.
⇒
Electric motor defective.
⇒
Check the fuse.
⇒
Have fuse and lead checked by qualified
electrician.
⇒
Replace the connection cable or have it
checked by an electrician.
⇒
To correct the problem, refer to the
manufacturer or other approved service centre.