Electric lock mode setting 

When the 

Camera Module 

is in standby. 

1. Press Key A, the 

Unlock Indicator 

will

 

turn 

on with the warning sound of a long Beep 
followed by a short Beep. 

2. Press Key A again to select mode 

Mode = 0 (default) 

Normally Open

: The 

Status indicator 

blinks 

once with the warning sound of a single long 
Beep 

Mode = 1 

Normally Closed

: The 

Status indicator 

blinks twice with the warning sound of a long 
Beep followed by a short Beep. 

 

 

 

Lock time delay setting 

When the 

Camera Module 

is in standby 

1. Press Key A, the 

Unlock indicator 

turns 

on with the warning sound of a long Beep 
followed by a short Beep. 

2. Press Key B and hold on to enter the 

Unlocking Time Delay Setting

, a warning 

sound of a short single Beep will be heard. 
The 

Status indicator 

will blink

 

once per 

second.

 

The 

Unlocking Time 

delay is indicated by the 

number of times that the 

Status indicator 

blinks (set in seconds). For example: The 

Status indicator 

blinks

 

four times, that 

means the unlocking time is 4 seconds. 

 

 

 

 

 

 

 

Sound setting 

When the 

Camera Module 

is in standby. 

1. Press and hold Key A for 3 seconds to 
enter the 

Sound Option Mode

, the 

Status 

indicator 

will

 

turn on and the current

 

sound will play. 

2. Press Key A again to play the next tune 

3. Press Key B to exit. 

 

 

 

Sound volume setting 

When the 

Camera Module 

is in standby. 

1. Press Key B to enter 

Tune Volume 

Setting

, the 

Talk indicator 

will

 

turn on and 

play the sound at the current volume. 

2. Press Key A to increase/decrease the 
volume (loop setting) 

3. Press Key B to exit. 

 

 

Talk volume setting 

1. During the conversation, press and hold 
Key B for 3 seconds to enter the 

Talk 

Volume Setting

The 

Talk indicator will 

turn on with the 

warning sound of a long Beep followed by a 
short Beep. 

2. Press Key A to increase/decrease the 
volume (loop setting). 

3. Press Key B to exit. 

 

 

 

 

 

Summary of Contents for A2400

Page 1: ...2 Wire System Installation Manual ...

Page 2: ...ors can be connected to a single call button Maximum of 4 monitors can be connected in daisy chain configuration Maximum of 8 monitors can be connected to single A2200 in distributor mode DIP switch 1 OFF Maximum of 4 A2200 units can be connected to single A2200 in raiser mode DIP switch 1 ON Cable distances CAT5e UTP cores twisted by colour code Twist the cores of CAT5e UTP as shown in the image ...

Page 3: ...switches for system configuration JP LK 2 Jumper for setting state of the NO contact CN KMB 3 Call button module A2400 connection port CN T COIL 4 Not in use BUS 5 L1 L2 bus line connecting to terminal BUS DS on the power supply CN LK 6 12V 12VDC power output LK Power ground LK Contact of the relay NO Normally open closed contact use JP LK jumper to set EB Exit button connection port EB Exit butto...

Page 4: ...lock time 0 is the default setting for one second delay and 1 is the setting for five seconds delay DIP switch 6 is for activating keys A and B which are used for programming camera module functions see next section The default setting for this DIP switch is 0 Video module functions and programming Activating touch keys A and B Key A and key B cannot be seen on the camera module until activated To...

Page 5: ...ing Time delay is indicated by the number of times that the Status indicator blinks set in seconds For example The Status indicator blinks four times that means the unlocking time is 4 seconds Sound setting When the Camera Module is in standby 1 Press and hold Key A for 3 seconds to enter the Sound Option Mode the Status indicator will turn on and the current sound will play 2 Press Key A again to...

Page 6: ... setting JP LK 1 2 Normally closed mode 2 3 Normally open mode Fail Locked Fail Unlocked Electric lock external power 1 The external power supply must be used accordingly to lock specification 2 The jumper must be taken off before connecting 3 Set lock type using touch keys A and B see module programming Fail Locked Mode 0 default Fail Unlocked Mode 1 ...

Page 7: ...odule A2400 Terminals 1 INPUT Connect to CN KMB port video module 2 OUTPUT Connect to next call module 3 J3 Call buttons 1 3 5 7 4 J4 Call buttons 2 4 6 8 Single module connections Connecting multiple modules Max 4 ...

Page 8: ...System layout Distributor mode ...

Page 9: ......

Page 10: ...System layout Riser mode ...

Page 11: ......

Reviews: