ATIGO A2400 Installation Manual Download Page 4

DIP switch settings for A3101

 

The system can be expanded up to 4 
entrance panels and 32 internal monitors 

The video module is configured by 6 DIP 
switches. 

The DIP switches can be modified either 
before or after installation. Restarting the 
camera module is necessary whenever the 
DIP switches have been modified. 

 

 

 

DIP switches 1 and 2 

are for door station(s) 

ID settings. 

When multi door stations are installed on the 
system, these two DIP switches must be set 
correctly. 

Door station DIP switch setting: 

No.1 = 

00

 (Default setting) 

No.2 = 

01

 

No.3 = 

10

 

No.4 = 

11

 

DIP switch 3 

always needs to be set to 1 as it 

is required for correct mechanical call buttons 
operation. 

DIP switch 4 

is for call button(s) automatic 

allocation. Call buttons are automatically 
assigned to the indoor units. This DIP switch 
always needs to be set to 0. 

DIP switch 5 

is for setting door unlock time. 

0 is the default setting for one second delay 
and 1 is the setting for five seconds delay. 

DIP switch 6 

is for activating keys A and B    

which are used for programming camera 
module functions (see next section). 

The default setting for this DIP switch is 0. 

 

 

 

Video module functions and 
programming  

 

 

 

Activating touch keys, A and B 

Key A and key B cannot be seen on the 
camera module until activated. 

To activate the keys, set the DIP switch 6 to 
ON. 

Module settings: touch keys A and B 

DIP switch 6 must be set to ON while the 
others are set to OFF to program module. 

Restore factory settings 

Warning: 

All settings will be deleted if the 

Restore 

Factory Setting 

is activated. 

When the 

Camera Module 

is in standby 

short out the Exit Button Port (EB+, EB-), 

and toggle the DIP switch 6 four times, with a 
warning sound of long Beep, and all three 
indicators blink at the same time, 

meaning that the 

Restore Factory Setting 

is 

in progress. Once the three Indicators turn off 
with a warning sound of a single long Beep, it 
means the 

Restore Factory Setting 

is 

complete. 

 

 

Summary of Contents for A2400

Page 1: ...2 Wire System Installation Manual ...

Page 2: ...ors can be connected to a single call button Maximum of 4 monitors can be connected in daisy chain configuration Maximum of 8 monitors can be connected to single A2200 in distributor mode DIP switch 1 OFF Maximum of 4 A2200 units can be connected to single A2200 in raiser mode DIP switch 1 ON Cable distances CAT5e UTP cores twisted by colour code Twist the cores of CAT5e UTP as shown in the image ...

Page 3: ...switches for system configuration JP LK 2 Jumper for setting state of the NO contact CN KMB 3 Call button module A2400 connection port CN T COIL 4 Not in use BUS 5 L1 L2 bus line connecting to terminal BUS DS on the power supply CN LK 6 12V 12VDC power output LK Power ground LK Contact of the relay NO Normally open closed contact use JP LK jumper to set EB Exit button connection port EB Exit butto...

Page 4: ...lock time 0 is the default setting for one second delay and 1 is the setting for five seconds delay DIP switch 6 is for activating keys A and B which are used for programming camera module functions see next section The default setting for this DIP switch is 0 Video module functions and programming Activating touch keys A and B Key A and key B cannot be seen on the camera module until activated To...

Page 5: ...ing Time delay is indicated by the number of times that the Status indicator blinks set in seconds For example The Status indicator blinks four times that means the unlocking time is 4 seconds Sound setting When the Camera Module is in standby 1 Press and hold Key A for 3 seconds to enter the Sound Option Mode the Status indicator will turn on and the current sound will play 2 Press Key A again to...

Page 6: ... setting JP LK 1 2 Normally closed mode 2 3 Normally open mode Fail Locked Fail Unlocked Electric lock external power 1 The external power supply must be used accordingly to lock specification 2 The jumper must be taken off before connecting 3 Set lock type using touch keys A and B see module programming Fail Locked Mode 0 default Fail Unlocked Mode 1 ...

Page 7: ...odule A2400 Terminals 1 INPUT Connect to CN KMB port video module 2 OUTPUT Connect to next call module 3 J3 Call buttons 1 3 5 7 4 J4 Call buttons 2 4 6 8 Single module connections Connecting multiple modules Max 4 ...

Page 8: ...System layout Distributor mode ...

Page 9: ......

Page 10: ...System layout Riser mode ...

Page 11: ......

Reviews: