6. Specifications
6.1 Storage and Operating Conditions
6.1.1 Temperature
Storage Temperature, °C Operating Temperature, °C
NETOEM
-40 to +100
-20 to +80
NETAOEM
-40 to +100
-20 to +80
6.2 Electrical Specifications
6.2.1 Power Supply
Power Source
†
Minimum
Voltage
Maximum
Voltage
Maximum Power
Consumption
Power over Ethernet
‡
through P602
36V
57V
6W
DCIN through P603
11V
25V
6W
†
Power is drawn from only one power source at a time.
‡
Conforms to IEEE 802.3af, class 0, receiving power from data lines.
6.2.2 Threshold Relay
The threshold relay contacts (NC_P, NO_P and COM_P on P605) are protected
against overload by a resettable fuse. The maximum guaranteed fuse hold current is
50mA.
The unprotected relay contacts NC, NO and COM are specified for a max. current of
1A at 30VDC.
Relay Contact Information
Rated load
0.3A at 125VAC, 1A at 30VDC
Max. operating current
1A
Max. operating voltage
125VAC, 60VDC
Max. switching capacity
37.5VA, 30W
Min. permissible load
10uA at 10mVDC
6.3 Weights and Dimensions
Component
Weight (approx.)
Dimensions
9010-05-1106 Net Digital
Board
55g (1.94oz)
See drawing in Section 7.1
9010-05-1107 Net Analog
Board
14g (0.49oz)
See drawing in Section 7.1