background image

 

 

 

ATI Audio Inc.      

     Tel: 856-626-3480      

      Fax: 856-504-0220      

     [email protected]      

      www.

 

 

audio.com 

 

The  inputs  are  protected  from  over-voltage  inputs  by  clipping  diodes.  Dual 
bypass capacitors protect the inputs against common mode RF pickup. Balanced 
potentiometers (R15 and R16) allow setting a precise null for common mode hum 
inputs. 
 
 

OUTPUTS 

 
Audio  from  the  input  buffer  is  AC  coupled  to  the  front  panel  level  adjust 
potentiometers. 
 
The pot outputs are applied to the non-inverting input of the HI (in-phase) output 
stage  driver  ICs.  The  ICs  supply  the  first  10ma  of  output  current  directly,  and 
then  complementary  Class  B  output  booster  transistors  take  over.  The  unique, 
wide  bandwidth,  high  slew  rate  circuit  design  provides  effective  class  AB 
operation with minimal crossover distortion from a power output stage operating 
true Class B with zero quiescent power dissipation. 
 
The HI output bus is inverted and boosted to drive the LO output bus. 
 
The  HI  and  LO  output  buses  of  each  channel  are  split  into  four  individual 
balanced outputs through 150 ohm build-out resistances. All outputs will tolerate 
short  circuits  across  the  output  or  to  the  ground  without  damage.  Up  to  two 
outputs  can  be  shorted  with  no  significant  reduction  in  headroom.  Needless  to 
say, this is NOT the recommended mode of operation. Do not drive a LO output 
into  the  grounded  end  of  an  unbalanced  load.  Drive  single  ended  loads  from 
either  the  HI  or  LO  output  to  ground.  Up  to  16  single-ended  600  ohm  output 
loads may be simultaneously driven by the DA2008-1. 
 
The  build-out  resistors  are  split  and  heavily  bypassed  to  prevent  RF  pickup  on 
the output lines from affecting operation of the DA. These bypasses will place a 
very  heavy  load  on  the  outputs  under  sustained  sine  wave  operation  above 
20Khz  and  such  operation  may  over-dissipate  the  47  ohm  build-out  resistors

don’t do it! 
 

OUTPUT CLIPPING INDICATOR S 

 
The differential input voltage of each HI output driver IC is monitored by a section 
of  A3.  The  differential  voltage  is  under  a  few  millivolts  under  linear  operation; 
however,  if  the  output  is  driven  to  clipping  the  differential  voltage  rapidly 
increases and is amplified to light the yellow OUTPUT CLIPPING LED. Conserve 
power

—try not to light the yellow LED. 

Summary of Contents for DA2008-1

Page 1: ...ATI Audio Inc Tel 856 626 3480 Fax 856 504 0220 sales atiaudio com www audio com Copyright 2011 ATI Audio Inc DA2008 1 DUAL 1X4 DISTRIBUTION AMPLIFIER OPERATING AND MAINTENANCE MANUAL ...

Page 2: ...udio use and in particular provides a high slew rate capability of 13 volts microsecond virtually eliminating slew induced Transient Intermodulation Distortion By contrast the old standard 741op amp has a slew rate of only 6V microsecond This op amp is now available from several U S manufacturers in single and dual versions and forms the basis for our Model DA2008 1 design This chip incorporates a...

Page 3: ...d outputs through 150 ohm build out resistances All outputs will tolerate short circuits across the output or to the ground without damage Up to two outputs can be shorted with no significant reduction in headroom Needless to say this is NOT the recommended mode of operation Do not drive a LO output into the grounded end of an unbalanced load Drive single ended loads from either the HI or LO outpu...

Page 4: ... rack Filler Shelf ATI Part Number 21098 501 is available if you are rack mounting only one unit WIRING The DA2008 1 line cord contains a three wire grounded plug The third wire ground can cause a ground loop with your facility ground If you are sure your facility ground will provide adequate protection to personnel in case of an AC line short to chassis a 3 to 2 AC adapter can be used to isolate ...

Page 5: ...tion by connecting one between HI and GND and the other between LO and GND The two loads thus driven will be out of phase with each other Maintenance Notes IC power supply voltages are and 16 VDC nominal If zeners are replaced remove ICs and check output voltage before plugging ICs back into the circuit Remove power when inserting or removing or ICs IC output DC voltages under no signal conditions...

Page 6: ...CTION 80dB for common mode hum inputs INPUT IMPEDANCE Balanced differential inputs 30 000 ohm bridging 24dBm maximum input level GAIN 26dB front panel adjustable OUTPUT ISOLATION 70dB minimum at 1 kHz any output to any other output unit will tolerate up to two shorted outputs with no reduction in headroom POWER 115 230 VAC 10 47 63 Hz SIZE 8 1 2 21 6cm W x 1 3 4 4 5cm H x 7 17 8cm D SHIPPING WEIGH...

Page 7: ...duct that has been discontinued from its product line with a new product of comparable value and function This warranty shall be void in the event a covered product has been damaged or failure is caused by or attributable to acts of God abuse accident misuse improper or abnormal usage failure to follow instructions improper installation or maintenance alteration or lightning power fluctuations and...

Reviews: