Filling of refrigerant, PAG oil and UV
(The device is supplied empty, fill the device with refrigerant, PAG oil)
1.
Connect the external refrigerant to the A/C
device as shown in the picture (note the
details of the refrigerant manufacturer).
2.
Open the valve of the external refrigerant
bottle
3.
Start the suction function on the A/C device.
4.
Once the required volume of refrigerant
sucked off (min. 2 kg, max. 10 kg), close the
valve of the external refrigerant bottle and
wait until the A/C unit automatically stops the
suction function. Then remove the external
refrigerant bottle. The A/C device is now
ready for use.