Technical specification

Power supply
• V

CC

• Power consumption

10 

 30 V 

2 W

Environment

In-operation

• Ambient temperatures
• Humidity

 50

O

C

10 – 90% long term, non-condensing

IP

IP20

Digital communication parameters
• JCS port 

• Electric standard
• Communication protocol

• EBUS port

• Electric standard
• Communication protocol

RS-485
Sigma Bus

RS-485
Sigma Bus

Protection class

III

Dimensions
• Height
• Width
• Depth

See figure 1

Acceptable cables

 2 mm

2

Enclosure material

Self-extinguishing PPO

Weight

0.3 kg

Mounting

DIN-35 / TS35 rail

Table 4: Technical specification

8

List of accessories

Product code

Description

PW-049-CB6

CB6 Service Cable 

Table 5: List of accessories

9

Product marking

Product code

Device

PW-027-A

Sigma MOD DRV Control Unit Module 

Table 6: Method of product's marking

10

Appendices

[1]

DEZG015-ENG – EU Declaration of Conformity – Sigma MOD DRV

p. 10|10

User's Manual: POD-005-ENG R02

Summary of Contents for Sigma MOD DRV

Page 1: ...POD 005 ENG R02 User Manual Control Unit Module Sigma MOD DRV Product code PW 027 A...

Page 2: ...tel 48 32 238 87 94 fax 48 32 234 92 71 e mail contact atestgaz pl www atestgaz pl We design manufacture implement and support Systems for Monitoring Detection and Reduction of gas hazards We invite...

Page 3: ...protected facility may involve other requirements throughout all stages of the product life How to use this manual The following symbols of optical indicators status are used throughout the document S...

Page 4: ...tion 9 7 Technical specification 10 8 List of accessories 10 9 Product marking 10 10 Appendices 10 List of tables Table 1 Optical indicators status notation 3 Table 2 Electric interface description 6...

Page 5: ...odule is equipped are intended to provide information on the current state of the system operation Basic functionality Providing real time system features ensuring the receipt of data from all the sys...

Page 6: ...ailure relay output negated COM Common terminal of relay NO Normally open contact of relay 5 EBUS External communication port A Signal line A B Signal line B GND Negative supply pole Both terminals GN...

Page 7: ...he device operates in the service mode STOP the device has been stopped FAILURE signalling the device failure Only equipment specifically designed for this purpose by the manufacturer of the Sigma MOD...

Page 8: ...difficult for unauthorized persons to access it It is recommended to use such mounting height which allows easy access to the unit If multi wired strands commonly referred to as cables are used for co...

Page 9: ...h moistened with water and a bit of a mild detergent 6 7 Utilization This symbol on a product or on its packaging indicates that the product must not be disposed of with other household waste Instead...

Page 10: ...85 Sigma Bus Protection class III Dimensions Height Width Depth See figure 1 Acceptable cables 1 2 mm2 Enclosure material Self extinguishing PPO Weight 0 3 kg Mounting DIN 35 TS35 rail Table 4 Technic...

Page 11: ...he use of certain hazardous substances in electrical and electronic equipment EN 50581 2012 This declaration of conformity is issued under the sole responsibility of the manufacturer Purpose and scope...

Page 12: ...www atestgaz pl Notes...

Page 13: ...www atestgaz pl Notes...

Page 14: ...www atestgaz pl Notes...

Page 15: ......

Page 16: ...M Pachole sp j Spokojna 3 44 109 Gliwice tel 48 32 238 87 94 fax 48 32 234 92 71 e mail contact atestgaz pl For more details on our devices and other products and services offered by us visit www ate...

Reviews: