Chapter 3. Operation
12
RS-232 Commands
Note:
Each command string can be separated with a space.
Task
RS-232 Command
Description
Switch Port
Switch output port(s) on
sw o<output_number> on Switch on one or all output ports. For
example, to turn output port 02, type
sw o02 on
output_number: 01-08, * (all output ports)
Switch output port(s) off
sw o<output_number> off Switch off one or all output ports. For
example, to turn off all output ports, type:
sw o* off
output_number: 01-08, * (all output ports)
EDID
Implement the display’s
EDID
edid portyy
Implement the EDID of the connected
display to Port yy, and pass it to the video
source.
yy: 01-08
Implement auto EDID
edid auto
Implement the EDID of all connected
displays. The VS0108HB uses the
best resolution for all displays.
Implement ATEN default
EDID
edid defaultyy
Implements the specified ATEN default
EDID configuration.
yy: 00-13, default is 00 (see
Baud Rate Setting
Set up the baud rate
baud <baud_rate_value>
For example, to set the baud rate to 9600,
type:
baud 9600
baud_rate_value: 9600, 19200 (default),
38400, 57600
Read Information
Read (display) the
VS0108HB’s settings
read
Reads and displays information from the
VS0108HB.
Reset
Reset the VS0108HB to
default factory settings
reset
-