ATEN UEH4002 User Manual Download Page 2

UEH4002 User Manual

ii

Thank you for purchasing the UEH4002.

Please read this guide thoroughly.

Federal Communication Commission Interference Statement

This equipment has been tested and found to comply with the limits for a Class B digital 
service, pursuant to Part 15 of the FCC rules. These limits are designed to provide 
reasonable protection against harmful interference in a residential installation. Any 
changes or modifications made to this equipment may void the user’s authority to operate 
this equipment. This equipment generates, uses, and can radiate radio frequency energy. 
If not installed and used in accordance with the instructions, it may cause harmful 
interference to radio communications. However, there is no guarantee that interference 
will not occur in a particular installation. If this equipment does cause harmful interference 
to radio or television reception, which can be determined by turning the equipment off and 
on, the user is encouraged to try to correct the interference by one or more of the following 
measures:

Š

Reorient or relocate the receiving antenna.

Š

Increase the separation between the equipment and receiver.

Š

Connect the equipment into an outlet on a circuit different from that to which the 
receiver is connected.

Š

Consult the dealer or an experienced radio/TV technician for help.

FCC Caution: Any changes or modifications not expressly approved by the party 
responsible for compliance could void the user's authority to operate this 
equipment.

CE Statement

We declare under our sole responsibility that the UEH4002, to which this declaration 
relates, is in conformity with European Standard EMC EN-55022:2006+A1:2007 Class B, 
EN 61000-3-2:2006, EN 61000-3-3:2003, and EN 55024:1998+A2:2003.

Suggestion:

Shielded twisted pair (STP) cables must be used with the unit to ensure compliance with 
FCC & CE standards.

IC Statement

This Class B digital apparatus complies with Canadian ICES-003.

RoHS

This product is RoHS compliant.

©2012-2014 ATEN International Co., Ltd.

ATEN and the ATEN logo are registered trademarks of ATEN International Co., Ltd. 

All rights reserved.

Summary of Contents for UEH4002

Page 1: ...Cat 5 USB 2 0 Extender UEH4002 User Guide www aten com...

Page 2: ...the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver...

Page 3: ...stalling the Remote unit 5 Connecting the Local unit to the Remote unit 6 Checking the Installation 6 Connecting a USB Device 7 Compatibility 7 Troubleshooting 7 Specifications 10 Limited Hardware War...

Page 4: ...Cat 5 cabling with two information outlets and two Cat 5 patch cords with RJ45 connectors if using premise cabling Note All references to Cat 5 cable in this document represent the minimum requiremen...

Page 5: ...002 system is properly enumerated on the host PC 4 Activity LED Amber Indicates activity when data transmission is active between Local and Remote LED blinks intermittently with or without a USB devic...

Page 6: ...owered off Orange when the Remote unit detects an overcurrent condition and the attached USB device attempts to draw more than the 500mA current 3 Power LED Blue LED turns on when power is supplied Of...

Page 7: ...UEH4002 User Manual 4 7 Power Port Connects to the AC power supply Required at Remote for proper operation 8 Link Port RJ45 Accepts RJ45 connector for Cat 5 cabling or better...

Page 8: ...ng premise cabling ensure Cat 5 cabling is installed between the two locations with Cat 5 information outlets located near both the computer and the USB device s and the total length including patch c...

Page 9: ...d Remote units check that the Power Host and Link LEDs are on and that the Activity LED is blinking If the Link LED is permanently off then the cabling between the Local and Remote unit is not install...

Page 10: ...t for further assistance PROBLEM CAUSE SOLUTION All LEDs on Local unit are off The Local unit is not receiving enough power from the USB port or the optional Local AC adapter 1 Ensure that the USB con...

Page 11: ...ting system from Suspend Standby mode see your operating system s documentation 2 Attach a USB device to the UEH4002 All LEDs on both the Local unit and Remote unit are on but the USB device does not...

Page 12: ...device documentation and power your USB device with the additional USB device manufacturer supplied power supply if available Device LED is orange and units are no longer functioning Overcurrent cond...

Page 13: ...s 2 0 1 1 High Full Low Speed 2 0 1 1 High Full Low Speed Maximum USB Devices Supported N A Direct 4 devices Cascaded 3 hubs 11 devices Power Consumption DC 5V 2 5W DC 5V 2 5W Environmental Operating...

Page 14: ...Liability The hardware warranty set forth in this agreement replaces all other warranties ATEN expressly disclaims all other merchantability and fitness for a particular purpose and non infringement...

Page 15: ...age The repaired or replaced item will be shipped to you at ATEN s expense not later than sixty days after ATEN receives the defective product Address the returned product to ATEN Technology Inc 19641...

Page 16: ...grity to support high speed communications USB Cables USB cables have two distinct connectors The Type A connector is used to connect the cable from a USB device to the Type A port on a computer or hu...

Page 17: ...UEH4002 User Manual 14 Table 2 T568B Wiring PIN PAIR WIRE CABLE COLOR 1 2 1 WHITE ORANGE 2 2 2 ORANGE 3 3 1 WHITE GREEN 4 1 2 BLUE 5 1 1 WHITE BLUE 6 3 2 GREEN 7 4 1 WHITE BROWN 8 4 2 BROWN...

Reviews: