The List Panel
The List panel contains six fields:
The Tick Panel
The lower panel displays tick information for the currently selected IP8000.
Note that if the installation contains more than one switch, even though a
switch isn’t currently selected, if its
Recording
checkbox is checked, the Log
Server records its tick information and keeps it in its database.
Field
Explanation
Recording
Determines whether the Log Server records log events for
this IP8000 or not. If the Recording check box is checked, the
field displays
Recording
, and log events are recorded
.
If the
Recording check box is not checked, the field displays
Paused
, and log events are not recorded.
Note:
Even though a IP8000 is not the currently selected
one, if its Recording check box is checked, the Log Server will
still record its log events.
Address
This is the IP Address or DNS name that was given to the
IP8000 when it was added to the Log Server (see
Port
This is the port number that was assigned to the IP8000 when
it was added to the Log Server (see
Connection
If the Log Server is connected to the IP8000, this field
displays
Connected
.
If it is not connected, this field displays
Waiting
. This means
that the Log Server's MAC address and/or port number has
not been set properly. It needs to be set in the
(see page 24) and specified in the
Configure
Days
This field displays the number of days that the IP8000's log
events are to be kept in the Log Server's database before
expiration (see
Description
This field displays the descriptive information given for the
IP8000 when it was added to the Log Server (see