Chapter 4. Configuration
55
Flow Control:
This allows you to choose how the data flow will be
controlled. Choices are: None, Hardware, and XON/XOFF. Set this to
match the flow control setting of the serial console device. Default is
None.
Note:
None is only supported for baud rates of 9600 and lower. For baud
rates greater than 9600, you must choose Hardware or XON/XOFF.
Enable Serial Port Bypass
: For DCE and DTE communication (see
component 2 & 3 of components on page 9), check this option.
Port Alert Properties
: You can specify up to 10 types of events (e.g.,
Power On). Enter them in the provided
Alert String
(1 - 10) fields.