PHYSICAL INSTALLATION IS COMPLETE.

 

ATEK’s Customer Care Team (CCT) must be contacted to 

complete tank setup. 

Verify/Change ATG Serial Communication Settings

ATG must be configured to the following communications port settings. Consult 
your ATG instruction manual for specific configuration instructions.

 

 

9600 baud  

  Parity = Odd 
  1 stop bit 
  7 data bits

Install TSC (continued)

Connect provided serial communications cable from ATG to TSC.

Plug in one end of Ethernet cable to TSC port.

Route cable to Internet router and connect to an open port.

4

5

6

Power-up TSC

Insert the TSC power connector until fully seated. Be sure to align locking 
ears and engage plug in socket fully. 
•  Status light will be solid GREEN at first. Once local network has  

 

 

assigned an IP address, light will change to flashing GREEN.

Ethernet light will normally be GREEN indicating connnection to network. 
Serial port light will normally remain AMBER changing to GREEN when 
ATG data is being transmitted to TankScan AIP.

Provide MAC address to CCT.

1

3

2

3

2

TankScan TSC 
Setup Instructions

223-0186-000  Rev. A  7/19

ATEK Customer Care Team (CCT) 

800-523-6996 or [email protected]

4

5