6
ALC-94 Series
.
If the HOLD input is active the value on the display is frozen. Witout cutting the signal in the HOLD input
the device will not count when the HOLD input is active.
.
To activate the Hold type press and hold Prg and press Rst button. Find Hld.typ menu by UP DOWN
buttons. Press Prg to see the menu. Press Prg again to flashing the options. Select the option and press
Prg button to save the setting
.
Press and hold Prg button and press RST button.find Snstype menu by Up Dpwn buttons. Press Prg
button to display the menu.Press Prg again to make flashing the options. Select the intended option by
Up Down buttons and save the option by pressing Prg button
.
.
It is used for selecting the edge counting numbers of A, B signals of the encoder. Counting options are
1,2, or 4. If the incremental encoder is connected to see the value in pulse type select 1 . When a linear
encoder connected to the device to make a high resolution measurement 4 option will be better
(quadrature mode). To change the edge counting option, press and hold Prg button and press Rst
button. Find the Cnt. Typ menu by UP DOWN buttons. Press Prg to see the menu. Pres Prg again to
make flashing the options.
Change the options by UP DOWN buttons. Press Prg to save the selected option.
Activating Hold Input ( Hld.inp )
Hold Type Selection ( Hldtyp )
Selecting Sensor Type (NPN/PNP) ( Sns.typ. )
Edge Counting Option ( Cnt.typ. )
So it will be beneficial to save the important settings. The device asks you for a password to return to
factory settings. It is 454 To restore the factory settings press and hold Prg button and press Rst
button. Find Fac.def menu by UP DOWN butons. Press Prg to see the options. There is YES and No
options in the menu. Press Prg again to make flashing the options. If you press to yes option the
device asks you the password. The password sets by UP Down buttons and use LEFT button to pass to
other digits. Press Prg to save the return to the factory settings.
Restoring Factory Settings ( Fac.def. )
Factory menu used for restoring factory settings. All the settings will be changed by this menu. So it
will be beneficial to save the important settings. The device asks you for a password to return to
factory settings. It is 454. To restore the factory settings press and hold Prg button and press Rst
button. Find Fac.def menu by UP DOWN butons. Press Prg to see the options. There is YES and No
options in the menu. Press Prg again to make flashing the options. If you press to yes option the
device asks you the password. The password sets by UP Down buttons and use LEFT button to pass to
other digits. Press Prg to save the return to the factory settings.
Factory menu used for restoring factory settings. All the settings will be changed by this menu. So it
will be beneficial to save the important settings. The device asks you for a password to return to
factory settings. It is 454. To restore the factory settings press and hold Prg button and press Rst
button. Find Fac.def menu by UP DOWN butons. Press Prg to see the options. There is YES and No
options in the menu. Press Prg again to make flashing the options. If you press to yes option the
device asks you the password. The password sets by UP Down buttons and use LEFT button to pass to
other digits. Press Prg to save the return to the factory settings.
Recording When The Energy is OFF ( Record )
Password Protection ( Protec )
Factory menu used for restoring factory
settings. All the settings will be changed
by this menu.
The used sensor can be selected by this menu. According to output
type of the sensor NPN veya PNP selection allows working with
different sensors