DSP Components
441
© 2017, ATEÏS, member of PAX ProAV Group
Control Window
Element Description
Mode: The type of filtering(high pass or low
pass).
Bypass: Disable the filter's module.
Level: The gain of the filter's module.
Frequency: The frequency of cut.
Graphical Control Window
Axis:
o
X: Frequency of output signal(Hz).
o
Y: Level of input signal(dB).
Control Points:
o
Blue: Adjust element Frequency(Horizontal)
and Level(Vertical).
5.7
Fireman
This component represents the Fireman Microphone with one channel audio output.
Control Window
Element Description
Mute: Mute the audio signal.
Monitor: Enable/disable the monitoring function if
the fireman mic has fault/shortcut.
Level: The level of Fireman component.
Paging-Event Selection: Select a paging event
using the Fireman component.
Before assigning a paging event to the
component, you need to create the event first.
chapter.
Paging-Event Link Button: To open the settings