IDA8 Global-Net User Manual
44
© 2017, ATEÏS, member of PAX ProAV Group
Device
Connection Max. Num
Function
Transceiver
DialPad can work without a physical connection.
Max. Number: The max. number of peripherals through per PDC port by using a Junction Box. For
example: On the PDC port, you can connect 32 PPM-AS through junction boxes and are able to
assign IDs in sequence for each unit in Ateis Studio.
Eth. Limit: The maximum number of IP that can be assigned over the network.
3.1.3.4
3rd Party Control
The following table lists the 3rd Party Control protocols supported by IDA8S.
Protocol
Interface
Function
Connection
Settings
Ateis 3rd Party
Protocol
Ethernet(UDP)
UDP Port = 19761
Read/Write value of parameters.
Stepped adjustment for parameters.
Modbus
PDC(RS485)
PDC Port 1~ 2
Level control
Paging
Read Monitoring Status
Read Evacuation Status
Play Message
Logic I/O Control
3.1.4
IDA8SL
The IDA8SL Low-Impedance slave unit houses advanced audio digital signal processing (DSP), matrix
control functions and a digital message player, along with amplifier monitoring with hot-swap amplifiers
and low-impedance line monitoring. Each input and output channel is fitted with a wide range of pre-
and post-processing devices such as volume controllers, routing mixers and switches, priority and
paging components, equalizers, compressors, limiters and delay-lines.
Security & Connectivity