4.  Rear panel features 

 

AC Power Inlet: 

The 3 pin IEC connector is located in the centre of the amplifier rear panel. It accepts a standard mains 
power lead fitted with an IEC connector. 
 

AC/DC Fuse Receptacles: 

Both AC and DC power inputs are protected by means of electronic fuses. There are no serviceable parts 
inside of the amplifier case. 
 

Power Switch: 

The power switch is located next to the power inlet on the rear panel. When the power switch is in the “ON” 
position, the front panel power LED will be lit. 
 

24VDC battery backup connector: 

The DPA

four

 amplifier can be operated with battery backup.  The connector is located on the central part of 

the amplifier rear panel. This 24VDC power supply can be used where AC power is not available or 
according to EN54 as a secondary supply. When in use, the front panel Power LED will activate in addition 
to the front panel DC LED. 
 

CAUTION!

  

If connected directly to a battery unit, this connection should be externally fused with 

 

 

50A max. 

 

 

This is not required when connected to the Ateis BECS150 Charger and Supply unit 

 

Channel 1-4 Audio Output: 

For each amplifier channel, there is a dedicated Audio Output connector for connection of a single selection 
from a 4Ohm loudspeaker load 

or

 one of a 50V, 70V or 100V line loudspeaker load not to exceed the rating 

of the amplifier output. For each load type, the Com point is the –ve terminal. The 4Ohm, 50V, 70V and 
100V are the +ve terminals for each load type. 

 

Channel 1-4 Inputs: 

For each channel, there is a Euro terminal block balanced input. Each input offers gain adjustment as 
required. 
 

General Fault Output Contact: 

The fault contact indicates an amplifier fault by giving an opening contact. (NC) 
 

Service Request Output Contact: 

The Service Request contact indicates that maintenance is needed. This is indicated by giving an opening 
contact. (NC) 
 

Lamp Test Input Contact: 

By closing this input contact, all LEDs on the front display of the amplifier will activate. 
 

Spare Input Contact: 

For future use. 
 

Configuration switches: 
 

Summary of Contents for DPAfour125

Page 1: ...47BP ROTTERDAM NETHERLANDS Phone 31 0 10 2088690 Fax 31 0 10 2088699 P O box 12172 3004 GD ROTTERDAM Chamber of commerce 24465391 Rotterdam version revision date 01 02 24 02 2012 D e l i v e r i n g Y o u r M e s s a g e Operating manual DPA Series DPA 10UMS01 V01R04 DPAfour125 DPAfour250 AMPLIFIERS Operating Manual ...

Page 2: ...pe com Page 2 of 11 1 Introduction 3 2 General description 3 3 Front Panel Features 4 4 Rear panel features 5 5 Wiring Examples 7 6 Block Diagram 8 7 Technical Data Overview 9 8 Safety Declaration 10 9 International sales and service points 11 ...

Page 3: ...alarm systems For safety installations each amplifier module is fitted with its own 230 VAC 24 VDC power supply for increased system reliability To avoid handling errors the gain setting for each amplifier channel is set using the potentiometer located at the back of the apparatus In addition to standard electronic protection DPAfour amplifiers also have electronic and thermal protection to protec...

Page 4: ...evel has been reached Temperature If the device internal temperature exceeds 95 degrees C the TEMP LED will light and the associated amplifier will shut down until the temperature falls below 95 degrees C The amplifier will resume function automatically Always ensure that a rack cabinet is sufficiently well ventilated DC The DC LED activates when the DPAfour amplifier is powered by a 24VDC power s...

Page 5: ...LED CAUTION If connected directly to a battery unit this connection should be externally fused with 50A max This is not required when connected to the Ateis BECS150 Charger and Supply unit Channel 1 4 Audio Output For each amplifier channel there is a dedicated Audio Output connector for connection of a single selection from a 4Ohm loudspeaker load or one of a 50V 70V or 100V line loudspeaker load...

Page 6: ...requirements of EN54 16 9 most indicators are off All indicators will be working 2 ON OFF Sleep modus disabled when working on battery power Sleep modus enabled wake up is done by 18 20 KHz monitoring tone 3 ON OFF Sleep modus disabled when working on battery power Sleep modus enabled wake up is done by 18 20 KHz monitoring tone 4 No function ...

Page 7: ... ateis europe com Page 7 of 11 5 Wiring Examples Diva 8 DPA wiring example with DPA ch 1 2 combined IDA8 DPA wiring example In case of combined DPA channels gain settings should be set at equal level for both channel 1 2 and or 3 4 ...

Page 8: ...DPAfour Series User Manual www ateis europe com Page 8 of 11 6 Block Diagram ...

Page 9: ...al output power per channel driven into nominal load 1kHz 55 c ambient W TBA TBA Nominal balanced input level for 100V output 1kHz and nominal load V 0 775 Balanced input level trim range for 100V output 1kHz and nominal load V 0 775 8 Max balanced input level V 8 Input impedance 1kHz Ω 20K Input common mode rejection 1kHz dB 60 Frequency response 3dB Hz 50 20k 80Ω 62 5nF 50 20k 40Ω 62 5nF Output ...

Page 10: ... damaged power cord is a fire and electrical shock hazard Do not cut scratch bend twist pull or heat the power cord A damaged power cord is a fire and electrical shock hazard Ask your ATEÏS dealer for replacement Immediately turn off the unit remove the power cord from the AC outlet and consult your ATEÏS dealer in any of the following circumstances Smoke odour or noise coming from the unit Foreig...

Page 11: ... 0 C and 55 C 32 F and 130 F Turn off all audio equipment when making any connections to the DPAfour and make sure to use adequate cables Do not use benzene thinner or chemicals to clean the DPAfour Use only a soft dry cloth If the DPAfour is moved from a cold place e g overnight in a car to a warmer environment condensation may form inside the unit which may affect performance Allow the DPAfour t...

Reviews: