8.  Safety Declaration 

 

 

Do not expose the DPA

four

 to extreme temperatures, direct sunlight, humidity, or dust, which could 

cause fire or electrical shock hazard. 

 

Keep away water or other liquids from the DPA

four

, otherwise fire or electrical shock may result. 

 

This  unit  is  equipped  with  a  single  pole  disconnect  device  (fuse)  in  the  phase  (live)  wire.  If  an  un-polarised 

mains connection is used, the receptacle the unit is connected to must be equipped with a two pole disconnect device 
(fuse) of appropriate rating!

 

 

Connect  the  power  cord  only  to  an  AC  outlet  of  the  type  stated  in  this  Owner's  Manual  or  as 

marked on the unit, otherwise fire and electrical shock hazard results. 

 

When disconnecting the power cord from an AC outlet always grasp the plug. Never pull the cord. 

A damaged power cord is a potential risk of fire and electrical shock hazard. 

 

Avoid touching power plugs with wet hands. Doing so is a potential electrical shock hazard. 

 

Observe  the  correct  polarity  when  operating  the  DPA

four

  from  a  DC  power  source.  Reversed 

polarity may cause damage to the unit or the batteries. 

 

Avoid placing heavy objects on power cords. A damaged power cord is a fire and electrical shock 

hazard. 

 

Do not cut, scratch, bend, twist, pull, or heat the power cord. A damaged power cord is a fire and 

electrical shock hazard. Ask your ATEÏS dealer for replacement. 

 

Immediately  turn  off  the  unit,  remove  the  power  cord  from  the  AC  outlet  and  consult  your  ATEÏS 

dealer in any of the following circumstances: 

 

Smoke, odour, or noise coming from the unit. 

 

Foreign objects or liquids falling inside the DPA

four

 

The unit has been dropped or the shell is damaged. 

 

The power cord is damaged. 

If you continue using the DPA

four

, fire and electrical shock may result. 

 

Do not drop or insert metallic objects or flammable materials into the unit as this may result in fire 

and electrical shock. 

 

Do not remove the DPA

four

 's cover, as there are exposed parts inside carrying high voltages that 

may cause an electrical shock. Contact your ATEÏS dealer if internal inspection, maintenance, or repair is 
necessary. 

 

Do  not  try  to  make  any  modifications  to  the  DPA

four

.  This  is  a  potential  fire  and  electrical  shock 

hazard. 

 

Slots  and  openings  in  the  unit  are  provided  for  ventilation.  To  ensure  reliable  operation  and  to 

prevent overheating of the unit, these openings must not be blocked or covered! 

 

Leave  enough  space  above  and  below  the  unit  to  provide  good  ventilation  of  the  DPA

four

.  If  the 

airflow is not adequate, the DPA

four

 will overheat and may cause a fire. 

 

Summary of Contents for DPAfour125

Page 1: ...47BP ROTTERDAM NETHERLANDS Phone 31 0 10 2088690 Fax 31 0 10 2088699 P O box 12172 3004 GD ROTTERDAM Chamber of commerce 24465391 Rotterdam version revision date 01 02 24 02 2012 D e l i v e r i n g Y o u r M e s s a g e Operating manual DPA Series DPA 10UMS01 V01R04 DPAfour125 DPAfour250 AMPLIFIERS Operating Manual ...

Page 2: ...pe com Page 2 of 11 1 Introduction 3 2 General description 3 3 Front Panel Features 4 4 Rear panel features 5 5 Wiring Examples 7 6 Block Diagram 8 7 Technical Data Overview 9 8 Safety Declaration 10 9 International sales and service points 11 ...

Page 3: ...alarm systems For safety installations each amplifier module is fitted with its own 230 VAC 24 VDC power supply for increased system reliability To avoid handling errors the gain setting for each amplifier channel is set using the potentiometer located at the back of the apparatus In addition to standard electronic protection DPAfour amplifiers also have electronic and thermal protection to protec...

Page 4: ...evel has been reached Temperature If the device internal temperature exceeds 95 degrees C the TEMP LED will light and the associated amplifier will shut down until the temperature falls below 95 degrees C The amplifier will resume function automatically Always ensure that a rack cabinet is sufficiently well ventilated DC The DC LED activates when the DPAfour amplifier is powered by a 24VDC power s...

Page 5: ...LED CAUTION If connected directly to a battery unit this connection should be externally fused with 50A max This is not required when connected to the Ateis BECS150 Charger and Supply unit Channel 1 4 Audio Output For each amplifier channel there is a dedicated Audio Output connector for connection of a single selection from a 4Ohm loudspeaker load or one of a 50V 70V or 100V line loudspeaker load...

Page 6: ...requirements of EN54 16 9 most indicators are off All indicators will be working 2 ON OFF Sleep modus disabled when working on battery power Sleep modus enabled wake up is done by 18 20 KHz monitoring tone 3 ON OFF Sleep modus disabled when working on battery power Sleep modus enabled wake up is done by 18 20 KHz monitoring tone 4 No function ...

Page 7: ... ateis europe com Page 7 of 11 5 Wiring Examples Diva 8 DPA wiring example with DPA ch 1 2 combined IDA8 DPA wiring example In case of combined DPA channels gain settings should be set at equal level for both channel 1 2 and or 3 4 ...

Page 8: ...DPAfour Series User Manual www ateis europe com Page 8 of 11 6 Block Diagram ...

Page 9: ...al output power per channel driven into nominal load 1kHz 55 c ambient W TBA TBA Nominal balanced input level for 100V output 1kHz and nominal load V 0 775 Balanced input level trim range for 100V output 1kHz and nominal load V 0 775 8 Max balanced input level V 8 Input impedance 1kHz Ω 20K Input common mode rejection 1kHz dB 60 Frequency response 3dB Hz 50 20k 80Ω 62 5nF 50 20k 40Ω 62 5nF Output ...

Page 10: ... damaged power cord is a fire and electrical shock hazard Do not cut scratch bend twist pull or heat the power cord A damaged power cord is a fire and electrical shock hazard Ask your ATEÏS dealer for replacement Immediately turn off the unit remove the power cord from the AC outlet and consult your ATEÏS dealer in any of the following circumstances Smoke odour or noise coming from the unit Foreig...

Page 11: ... 0 C and 55 C 32 F and 130 F Turn off all audio equipment when making any connections to the DPAfour and make sure to use adequate cables Do not use benzene thinner or chemicals to clean the DPAfour Use only a soft dry cloth If the DPAfour is moved from a cold place e g overnight in a car to a warmer environment condensation may form inside the unit which may affect performance Allow the DPAfour t...

Reviews: