ATECPOOL SIROCCO HEAT PUMP > User Manual
5
III.
Installation Instructions
WARNING: Only a professional is allowed to install the heat pump. Unqualified users cannot
install by themselves, otherwise the heat pump might be damaged and the user's safety
will be risked.This section is provided for information purposes only and must be checked
and adapted if necessary, according to actual installation conditions.
1. Pre-Requirements
Equipment needed for installation of heat pump:
● Suitable power supply cable for unit’s power.
● A by-pass kit and an assembly of PVC tube, stripper, PVC adhesive and sandpaper.
● A set of wall plugs and an expansion screw.
● We recommend using a flexible PVC pipe in order to reduce transmission of vibration.
● Suitable fastening studs may be used to raise the unit.
2. Location and pipe connection
IMPORTANT: The inverter pool heat pump should be installed in a good ventilation place.
1) The frame must be fixed by bolts (M10) to a concrete base or brackets. The
concrete base must be solid and fastened; the bracket must be strong enough and
antirust treated;
2) Please don’t stack substances that will block air flow near inlet or outlet area, make sure
there is no barrier within 50cm behind the main machine, or the efficiency of the heater will
be reduced or the machine may break;
3) The machine needs an appended pump (not included with the heat pump).
For the recommended pump specification-flux: refer to Technical Parameter,
Max. Lift ≥10m;
4) When the machine is running, there will be condensation water discharged from the
bottom, please pay attention to it. Please hold the drainage nozzle (accessory) into the
hole and clip it well, and then connect a pipe to drain the condensation water out.
Do not place anything within at least 1m in front of the heat pump. Leave at least 50cm of empty space around the sides and
rear of the heat pump. Do not put anything on or in front of the heat pump!