Indicator Light not on

1.  If the light does not come on, but water gets hot, check for faulty bulb.

2.  Check reset button; follow steps from previous section.

Brown water

1.  Brown or rusty water indicates a “spent” anode rod. Replace anode rod.

Odor in water

1.  Smells from the water are usually due to an unusual reaction between local water 

and the heater’s anode, check anode rod.  

This usually occurs on non-municipal water supplies.

Water is too hot

1.  Turn the temperature selector dial counter anti-clockwise to lower temperature.

2.  If temperature does not change then replace the thermostat.

No Water flow

1.  Check service valve is open and ensure minimum operation pressure is above 1 

bar.  

Note: This water heater is not suitable for use on gravity fed systems.

Unit Leaking

1.  Check water connection fittings at the top of tank, ensure the connections to the 

water heater are sound and are not the cause of the leak; if they are leaking, tighten 

the connections.

2.  Inspect heating element gasket for cracks or perishing if there are any signs of 

damage replace element and gasket together.  

NOTE: Elements and Gaskets should always be replaced together; do not reuse an 

old gasket.

ATC Electrical and Mechanical provides a two year limited parts warranty for the ATC 

Pacific water heaters as long as the unit has been installed, used and maintained in ac-

cordance with the information provided in this manual. For full terms and conditions of 

sale and warranty please see 

www.atc.ie

.

In order to arrange parts for the heater, the information listed below is required. It is recom-

mended to write this information below and keep this instruction manual in a safe place. 

Serial Number:   

 

 

 

Date of Manufacture:

Date of Purchase: 

 

 

 

Location Purchased:

WARRANTY

Summary of Contents for W10-u

Page 1: ...Ireland IE 01 4678301 UK 0203 564 9164 Email sales atc ie 1 ATC PACIFIC WATER HEATING INSTALLATION AND OPERATION MANUAL W5 u 5 Litre Undersink water heater W10 u 10 Litre Undersink water heater W15 u...

Page 2: ...examine and if necessary replace the anode rod at least once a year could cause the tank to fail and leak and void the warranty 8 Cable connection should be to a 13A double pole Switched Spur 9 This...

Page 3: ...nter 100 Thermostat Type Capillary type Thermostat Range C Min C Max 30 80 35 75 External Switch No Yes Heating Indicator LED Yes Installation location Undersink wall mounted or standing on rubber fee...

Page 4: ...the holes required always use screws that are suitable for the wall material and the weight of the heater otherwise the heater may pull the bracket off the wall Hang the water heater on the bracket Tu...

Page 5: ...dation must be made for the expanded water that will occur with each operating cycle Regulations permit expanded hot water to be accommodated within the supply pipe work provided that an expansion rel...

Page 6: ...in the pipework is not possible An expansion vessel must be used Cold in Hot out 5 10 or 15 Ltr Water heater CLOSED SYSTEM THERMAL EXPANSION There is a Pressure relief safety valve supplied with the...

Page 7: ...rs shall only switch on off the water heater provided that it has been installed in its intended normal operating position and they have been given instruction concerning use of the heater in a safe w...

Page 8: ...oint outlined above check the water tempera ture do not place hands directly under water outlet as there could be a risk of scalding If it is necessary to adjust thermostat turn the dial clockwise to...

Page 9: ...acidity alkalinity in the water supply To replace the Anode 1 Turn off the power supply and drain the heater see previous section 2 Remove heating element see previous section 3 Remove the spent anod...

Page 10: ...thermostat to desired setting Note a lower setting is more economical and reduces the risk of scalding CAUTION Call a technician if the high limit needs to be reset frequently 5 Litre Hi Level Reset...

Page 11: ...heater is not suitable for use on gravity fed systems Unit Leaking 1 Check water connection fittings at the top of tank ensure the connections to the water heater are sound and are not the cause of th...

Page 12: ...65 ERP RATING INFORMATION Waste Electrical Electronic Equipment Applicable in the European Union and other European countries with separate collection systems This marking shown on the product or its...

Reviews: