Events
Documentation of manual interventions (max.
1000). E.g. Changes of run times.
Return using
OK
.
Messages
Every change of status is documented here; e.g.
when the float switch has switched, when the
compressor has switched on and off (also whether
automatically or manually), failure of the mains
supply voltage.
Settings
All relevant settings can be reviewed here.
Modifications are, with the exception of the confirmation of a sludge removal
and of the signal tone, are possible in the Service Mode.
Operating parameters
feeding
: specification of the feeding time (with
the BASIC the number of charging batches) for
the build-up of the communicating pipe between
coarse filter and sludge activation.
fed. pause
:
Time period between batches
.
Deni phase
: Duration of the denitrification
phase. The denitrification phase is component
part of the aeration phase and takes place
following the charging.
Deni aer. ON/OFF
: Aeration times/pauses
during the denitrification phase.
Aer. phase
: Duration of the complete charging phase
.
ON/Off norm
: Aeration times/pauses during the normal phase.
Aer. ON/OFF econ
: Aeration times/pauses during the economy
phase.
sediment.
: Duration of the settling phase.
CW evacuation
: If the removal of the clarified water at the end of the
settling phase takes longer than the run time specified a flooding
warning takes place.
followup
: As the AQUA
switch
©
has a very small switching hysteresis,
the clarified water pump still continues to run on for the set time after