CP-01-2010 Supported Features for False Alarm
Reduction
Digital Life User Manual
|
Page
49
of
62
ATT-UM-V1.1-201303
Digital Life
Feature
Name
CP-01
Feature
Name
Settings
Default
Setting
Feature Description
Abort Delay
Abort Window
– for Non-Fire
Zones
(Windows)
Enabled/Disabled
with a range of
zero (0) to forty-
five (45) seconds
Enabled
with thirty
(30)
second
delay
The Abort Delay feature is the time
delay between when an alarm has
been triggered locally and when the
alarm is actually sent to the AT&T
Digital Life Central Monitoring
Center. The Abort Delay feature
enables you time to enter your Alarm
Panel PIN into a keypad in order to
disarm the system and cancel the
alarm before it is reported to the
AT&T Digital Life Central Monitoring
Center.
NOTE:
Consult with your Digital Life
Technician to determine if your
system is configured with a
communicator delay (Abort Delay).
An Abort Delay will prevent a report
to the AT&T Digital Life Central
Monitoring Center if your DLC-100 is
disarmed within thirty (30) to forty-
five (45) seconds after an intrusion
alarm is triggered. Note that fire-type
alarms are normally reported without
a delay.
Abort
Sound
Abort
Annunciation
Enabled/Disabled Enabled
The
Abort Sound feature generates
one (1) long beep from the keypad
when you abort an alarm during the
Abort Delay Time interval.
Cancel
Sound
Cancel
Annunciation
Enabled/Disabled Enabled
The Cancel Sound feature generates
two (2) long beeps from the keypad
when you cancel an alarm.
Cross
Zoning
Cross Zoning
Enabled/Disabled
with a range of
one (1) to thirty
(30) seconds
Disabled
Cross zoning is a configuring of logic
within the alarm panel such that two,
or more, zones of the security
system are interdependent in
causing an alarm. This feature is set
per device and disabled by default.
Swinger
Shutdown
Trips
Swinger
Shutdown
Enabled/Disabled
with one (1) to six
(6) trips
Enabled
with two
(2) trips
Swinger Shutdown is a false alarm
prevention feature that counts the
number of alarms caused by a
specific intrusion device. The system
will auto-bypass a specific intrusion
device based on the swinger
shutdown count setting. After a