AT&T DLC-100 User Manual Download Page 1

 

 

 

 

 

 

 

 

 

 

 

Digital Life User Guide 

ATT-UM-V1.1-201303

 

Summary of Contents for DLC-100

Page 1: ...Digital Life User Guide ATT UM V1 1 201303...

Page 2: ...2012 2013 AT T Intellectual Proprieties All rights reserved Product Number ATT UM V1 1 201303...

Page 3: ...ul interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following m...

Page 4: ...ed range 3 A receiver cannot respond to more than one transmitted signal at a time and may be blocked by radio signals that occur on or near their operating frequencies regardless of code settings 4 C...

Page 5: ...ularly at plugs convenience receptacles and the point where they exit from the apparatus 11 Only use attachments accessories specified by the manufacturer 12 Use only with the cart stand tripod bracke...

Page 6: ...rotect from Exposure to Moisture and Foreign Objects WARNING Avoid electric shock and fire hazard Do not expose this product to dripping or splashing liquids rain or moisture Objects filled with liqui...

Page 7: ...tery Replacement Warnings WARNING The battery ies used in each device may present a fire or chemical burn hazard if mistreated Do not recharge disassemble heat above 100 C 212 F or dispose of in fire...

Page 8: ...atures and Operation 6 Becoming Familiar with your Keypad SW ATT PAD2W Features 6 Display 6 System LIGHTs 7 Numeric Keypad 7 Function Buttons 7 Emergency Buttons 7 Operating Your Keypad SW ATT PAD2W 7...

Page 9: ...Smoke Detector SW ATT SMKT Operation 28 Replacing the Smoke Detector SW ATT SMKT Batteries 28 Testing Your Smoke Detector SW ATT SMKT 29 Maintaining the Smoke Detector SW ATT SMKT 29 Evacuation Plan...

Page 10: ...ctor SW ATT GB 39 Motion Sensor Features and Operation 40 Replacing the Motion Sensor SW ATT PIR Battery 40 Testing the PIR Motion Sensor SW ATT PIR 41 915MHz Repeater Features and Operation 42 Replac...

Page 11: ...fessionally installed in your home for alarm detection AT T Cellular Data Service for alarm reporting AT T Central Monitoring Centers with dedicated agents for handling alarms and contacting Emergency...

Page 12: ...ically reports intrusion alarms to the AT T Digital Life Central Monitoring Centers AT T Digital Life Central Monitoring Centers The AT T Digital Life Central Monitoring Centers are state of the art 2...

Page 13: ...tal Life System configuration Your Digital Life Technician has installed your DLC 100 in a closet utility room or basement Digital Life Controller DLC 100 Features 1 AT T Cellular Data Antenna 2 Anten...

Page 14: ...y needs to be replaced LIGHT OFF indicates the battery is dead or there is no battery SYSTEM GREEN LIGHT indicates your system is working RED LIGHT indicates your system has a problem YELLOW LIGHT ind...

Page 15: ...y compartment door when the system is armed triggers the transmission of a tamper alarm to the AT T Digital Life Central Monitoring Center Therefore in order to prevent a false alarm please ensure tha...

Page 16: ...ple the system can be configured so the keypad chirps when an entry exit door is opened and closed The keypad annunciates different sounds for fire alarms and intrusion alarms See Appendix A for infor...

Page 17: ...n selections and to access system functions Function Buttons You can use the function buttons to select the STAY AWAY and BYPASS features Emergency Buttons The Emergency Buttons are used to send an em...

Page 18: ...T is on and no message is displayed on the LCD Not Ready to Arm The system is not ready to arm because one or more of the supervised devices is not in the closed state Afterwards the keypad will displ...

Page 19: ...keypad beeps and the LCD displays Arming Exit Now Initially the keypad beeps slowly during the exit delay timer interval and then chirps fast for the last ten 10 seconds If you choose to exit while A...

Page 20: ...ing Exit Now Initially the keypad beeps slowly during the exit delay timer interval and then chirps fast for the last ten 10 seconds You should exit through the designated entry exit door s before the...

Page 21: ...ystem cannot arm because one or more sensor is in an opened state such as a window and or door You may close the open sensor s before arming or utilize the BYPASS feature The LCD will display Press BY...

Page 22: ...then chirps fast for the last ten 10 seconds NOTE You may disarm the system during the exit delay timer interval by entering your four 4 digit Alarm Panel PIN Disarming the System Entry Delay When th...

Page 23: ...anel PIN the READY Green LIGHT is illuminated and the LCD is blank Disarming the System When the system is in the Armed STAY mode or Armed AWAY mode you enter your four 4 digit Alarm Panel PIN to disa...

Page 24: ...rotected window or door while the system is armed the siren will start sounding the keypad starts beeping and the LCD displays Alarm Enter PIN to Cancel The keypad also displays the name of the device...

Page 25: ...e Fire Emergency as shown After you press the asterisk key a fire alarm will be sent to the AT T Digital Life Central Monitoring Center and the keypad will display FIRE Emergency Sent as shown The ala...

Page 26: ...isk key an AUX Emergency alarm will automatically be sent to the AT T Digital Life Central Monitoring Center and the keypad will display AUX Emergency Sent as shown The alarm has been sent to the AT T...

Page 27: ...Emergency as shown After you press the asterisk key a Police Emergency alarm will automatically be sent to the AT T Digital Life Central Monitoring Center and the keypad will display POLICE Emergency...

Page 28: ...been entered Keypad Operation Quick Reference FEATURE OPERATION STAY Press STAY to Arm STAY AWAY Press AWAY to Arm AWAY BYPASS Press STAY or AWAY then BYPASS Disarm Enter four 4 digit Alarm Panel PIN...

Page 29: ...attery installation 6 Restore the keypad to its base Keypad and Siren Sounds Your Keypad SW ATT PAD2W and Siren SW ATT SRN will make different audible sounds based on the actual event that is taking p...

Page 30: ...it Delay Keypad SW ATT PAD2W Slow short one 1 second beeping followed by fast beeping Beeps slowly during Exit Delay Timer Interval until last ten seconds then beeps fast Fire Alarm Siren SW ATT SRN a...

Page 31: ...atic prioritization of alarm signaling to the AT T Digital Life Central Monitoring Centers based on the type of alarm as indicated in the following table from highest to lowest priority Sounding and D...

Page 32: ...pad to silence chirping for four 4 hours Keypad Siren 433MHz Repeater 915MHz Repeater Smoke Detector CO Detector or Takeover Module Low Battery device name Low Battery and Press to Silence Press butto...

Page 33: ...l Your key fob has one LIGHT that flashes when a button is pressed and a signal is being transmitted to the DLC 100 It is battery operated and comes packaged with two 2 Panasonic CR2025 Lithium batter...

Page 34: ...Batteries are installed in the Key Fob SW ATT FOB during the production process The key fob is ready to use right out of the box To replace the batteries 1 Remove the top cover by inserting a coin in...

Page 35: ...tory four 4 digit Alarm Panel PIN An Alarm Panel PIN must be established before you will be able to arm and disarm your system You can also create change your Alarm Panel PIN by accessing www att com...

Page 36: ...Timer Interval feature allows you sufficient time to exit your home without tripping an alarm Siren Features and Operation Your wireless Siren SW ATT SRN is capable of generating alarms sounds and ch...

Page 37: ...teries Your Siren SW ATT SRN is equipped with two 2 non rechargeable 3VDC Duracell DL123A or Panasonic CR123A batteries The batteries provide twenty four 24 hour battery backup You must first remove t...

Page 38: ...re Alarm Verification feature can be used The DLC alarm verification period is twenty 20 seconds If the Fire Alarm Verification feature is enabled the Digital Life Controller DLC 100 waits for two 2 s...

Page 39: ...the smoke detector LIGHT is extinguished and the smoke detector will chirp every forty five 45 seconds until the batteries are replaced The low battery trouble chirps can be silenced for twenty four...

Page 40: ...arefully and only for their intended uses Do not overload electrical outlets Do not store explosive and or fast burning materials in your home Even after proper precautions have been taken fires can s...

Page 41: ...cals to help emergency personnel identify the sleeping quarters of these individuals WARNING Smoke alarms CANNOT provide warnings for fires resulting from explosions smoking in bed or other furniture...

Page 42: ...flashes every 30 seconds None Normal operation with good batteries Not sensing any CO None Carbon Monoxide alarm Red Alarm LIGHT flashes with beeps Four quick beeps 5 seconds silence repeating Alarm c...

Page 43: ...test purposes only Tamper Red Alarm LIGHT flashes every 30 seconds One quick beep every 30 seconds Unit is in tamper condition Place alarm body back onto mounting plate If condition continues unit has...

Page 44: ...mage or temporarily contaminate the sensor Avoid spraying air fresheners hair spray paint or other aerosols near the alarm Do not paint the unit Paint will seal the vents and interfere with proper sen...

Page 45: ...he AT T Digital Life Central Monitoring Center Therefore in order to prevent a false alarm please ensure that the system is disarmed prior to opening the battery compartment door to replace the batter...

Page 46: ...the system is armed triggers the transmission of a tamper alarm to the AT T Digital Life Central Monitoring Center Therefore in order to prevent a false alarm please ensure that the system is disarmed...

Page 47: ...to its housing Replace the cap for the transmitter assembly Insert the transmitter assembly into the door or window jam and install the screws for securing the transmitter if they were used in the ini...

Page 48: ...the Glass Break Sensor SW ATT GB Batteries CAUTION Opening the battery compartment door when the system is armed triggers the transmission of a tamper alarm to the AT T Digital Life Central Monitoring...

Page 49: ...ser Manual Page 39 of 62 ATT UM V1 1 201303 NOTE If batteries are not installed the sensor cannot be installed to its base Testing the Glass Break Detector SW ATT GB See the Test Your System section c...

Page 50: ...be capable of transmitting an alarm Replacing the Motion Sensor SW ATT PIR Battery The motion sensor includes low battery detection When the system indicates a low battery condition on the motion sens...

Page 51: ...e new battery ensure that careful attention is given to the polarity of the battery during battery installation Reattach the motion sensor to its back plate Testing the PIR Motion Sensor SW ATT PIR Se...

Page 52: ...z transmissions are not being received by the DLC 100 and will automatically repeat those 915MHz transmissions Your 915MHz repeater is equipped with two 2 non rechargeable 3V CR123 Duracell DL123A Pan...

Page 53: ...that is located at the top of the 915MHz Repeater SW ATT RPTR9 that secures the 915 MHz repeater to the AC outlet and then remove the unit from the AC outlet NOTE Be sure to observe the polarity of t...

Page 54: ...ce of the unit The green LIGHT blinks dimly and quickly when it detects 433MHz radio traffic that it is not repeating The green LIGHT blinks brightly and quickly when it detects 433MHz radio traffic t...

Page 55: ...sure to observe the polarity of the batteries during battery replacement After you have installed new batteries plug the 433 MHz repeater back into the lower socket of the AC outlet Then replace the r...

Page 56: ...s it may be installed in a different location in the home All of the zones in the takeover module act as supervised wireless zones in the Digital Life System In existing wired security systems the wir...

Page 57: ...at the top of the unit by turning the screw counterclockwise Be sure to keep the screw for reinstallation Remove the front cover on the takeover module to expose the battery compartment Replace the t...

Page 58: ...ings Default Setting Feature Description Exit Delay Timer Exit Time Forty five 45 to one hundred and twenty 120 seconds interval Sixty 60 second interval After arming your system the Exit Delay Timer...

Page 59: ...nter if your DLC 100 is disarmed within thirty 30 to forty five 45 seconds after an intrusion alarm is triggered Note that fire type alarms are normally reported without a delay Abort Sound Abort Annu...

Page 60: ...moke alarm to the AT T Digital Life Central Monitoring Center When the feature is not enabled if the DLC 100 receives one 1 smoke detection message from a smoke detector a smoke alarm is reported to t...

Page 61: ...essage will periodically appear in the keypad LCD Automatic Termination of Test Mode Automatic Termination A test duration interval must be selected ranging from four 4 minutes to twenty four 24 hours...

Page 62: ...anually take your DLS out of the Test Mode If you do not have your DLS manually taken out of the Test Mode the DLS will automatically return to normal operation after the test duration period ends Whe...

Page 63: ...llowing procedure o Arm the system in the Armed STAY Mode o Open one protected door or window o After the alarm has been observed enter your Alarm Panel PIN to cancel the alarm and then enter your Ala...

Page 64: ...to preserve battery life An Intrusion alarm has been sent to AT T Digital Life Central Monitoring Center with no action required CO Detector SW ATT CO DLS in Test Maintenance Mode End to End Testing T...

Page 65: ...IN again to clear the message Local Sensitivity Test Press the TEST SILENCE button for four 4 seconds Once the test starts the smoke alarm LED flashes one 1 to nine 9 times Count the number of flashes...

Page 66: ...reen LED will blink twice to indicate that the unit is in the RF test mode for 90 seconds o After alarm has been observed enter your Alarm Panel PIN to cancel the alarm and then enter your Alarm Panel...

Page 67: ...message Display Alarm Enter PIN to Cancel Keypad LCD will display Alarm Canceled Keypad LCD will display Enter PIN to Clear Keypad and Siren Fire Emergency SW ATT PAD2W SW ATT SRN DLS in Test Mode Pre...

Page 68: ...Cancel An Auxiliary Emergency alarm has been sent to AT T Digital Life Central Monitoring Center with no action required Keypad and Siren Police Emergency SW ATT PAD2W SW ATT SRN DLS in Test Mode Pres...

Page 69: ...STAY Mode o Open trip one device o After the alarm has been observed enter your Alarm Panel PIN to cancel the alarm and then enter your Alarm Panel PIN again to clear the message End to End Testing F...

Page 70: ...ng keypad one at a time by executing the following procedure o Press the FIRE button on an outlying keypad o When prompted press the asterisk key to confirm the Fire Emergency o After alarms have been...

Page 71: ...ain to clear the messages Outlying Siren Testing Test each outlying siren one at a time by executing the following procedure o Press the FIRE button on any keypad o When prompted press the asterisk ke...

Page 72: ...wing procedure o Arm the system in the Armed STAY Mode o Open one protected door or window o After the alarm has been observed enter your Alarm Panel PIN to cancel the alarm and then enter your Alarm...