background image

SECTION  502-610-418 

Page  4 

Notes  for  Fig.  2: 

I,  THE  635AD5C  KEY  IS  SUPPLIED  WITH  AN  ADAPTER  IN  THE  CUTOFF  KEY  POS I TION,  THE  SLATE 

MOUNTING  CORD  PLUG  CONNECTS  TO  THE  ADAPTER.  CONNECT  (BL·Y)  ANO  (Y·BL)  ADAPTER  LEADS  TO 
TERMI NALS 

AND  2,  RESPECT I VELY.  BALANCE  OF  PLUGS  CONNECT  D I RECTLY  TO  KEY. 

2.  ON  SETS  EQUI PPED  \liTH  A  658C  KEY,  THE  (G)  CONTACT  STRIP  LEAD  I S   TERM I NATED  ON  17  ANO 

(R)  ON  18.  I F   A  658C  KEY  IS  ADOED  IN  THE  F I ELD,  LEADS  MUST  BE  MOVED  FROM  PRECED I NG 

MODULE  CHAI NING  C I RCUIT  TO  TERM I NALS  17  AND  18. 

3.  PROVISIONS  ARE  MADE  FOil  MECHAN I CALLY  STOR I NG  THE  LIGHT  BE I GE  PLUG  ON  THE  658A  KEY,  NO 

ELECTRICAL  CONNECT I ON  IS  MADE. 

4.  WHEN  THE  658A  KEY  I S   REQU I RED  AS  A  DUAL  PURPOSE  KEY,  REMOVE  STRAP  BETWEEN  TERM I NALS 

17  AND  18.  USE  MIW  CORD  OR  EQUI VALENT  TO  CONNECT  TERMINAL  17  TO  A  D I SS I M I LAR  GROUND 
OR  NONGROUNDED  CIRCUIT. 

5.  TO  SUPPLY  "I"  HOLD  FEATURE,  TERMI NATE  (O·Y)  MOUNTING  CORD  LEAD  FROM  F I RST  MODULE  ON 

TERMINAL  24.  LEAD  BECOMES  SP  LEAD  AT  EQUIPMENT. 

6.  I F   HOLD  POSITION  LAMP  IS  REQUIRED,  CONNECT  (G·Y)  LAMP  LEAD  AND  (Y·G)  LAMP  GROUND  LEAD 

TO  (G•Y)  AND  (Y·G)  MOUNT I NG  CORD  (BL  BINDER)  LEADS,  RESPECTI VELY,  US I NG  SPARE 

TERMINAL  OR  D-161488  CONNECTOR.  LAMP  MUST  BE  SEPARATELY  ORDERED  ANO  I NSTALLED. 

7.  THESE  CONTACT  STRIPS  ARE  REQUIRED  WHEN  TELEPHONE  SET  IS  EQUIPPED  \liTH  THE  DI20K  (MD) 

OR  THE  D200S  (MD)  MOUNTING  CORD. 

INSULA TED  AND  STORED. 

1' 

DEAD  DRESSED. 

� 

BSP 

S02-610-418-i04_197S.Q3-Q4.jpg  Scanned by  Frank  Harrell,  (Cowboy  Frank) Castle Rock, Colorado  Feb 04, 2012  14:35:33 

Summary of Contents for 636CA

Page 1: ...key and will replace the 840151120 and 840151138 assemblies supplied with the 635A5C key 2 03 Because of the physical arrangement of the 635 type key the contact strips do not extend to the chaining switch This requires a second tip and ring to each module except the last See Fig 2 sheets 1 through 5 2 04 Mounting cords of these CALL DIRECTOR sets terminate in individual plugs connected to the rea...

Page 2: ...ting cord plugs and the two contact strips sets equipped with D120K MD or D200S MD mounting cords from the second module remove key and replace with 635A5C key 3 Reterminate contact strip leads and connnect mounting cord plugs with exception of white plug which is insulated and stored Note Contact strips are not required with sets equipped with D120M or D200AA mounting cords 4 Rearrange wiring per...

Page 3: ..._ ______ TO G Bll J BUZZER BL 6 2 2 GN NOTES I TO CONTACT STRIPS 1ST MODULE 2 TO CHAINING SWITCH I ST MODULE 3 NIA RINGER SHOWN TIA RINGER HAS 51 NGLE COIL 200 OHMS AND ONLY R AND BK LEADS LEGEND DP FL HS LS ON 01 Al PULS flASH K Y H AOS T JACKS LIN SWITCH OH NORMAL DIAL I NSULAT D AND STOR O NETWORK TERM1 NAL J UNDESIGNATEO AMPLIfI R T RMI NAL T RMI NALS AR ON T RM BOARD 40108 OR 422BF NETWORK Fi...

Page 4: ... 4 WHEN THE 658A KEY I S REQU I RED AS A DUAL PURPOSE KEY REMOVE STRAP BETWEEN TERM I NALS 17 AND 18 USE MIW CORD OR EQUI VALENT TO CONNECT TERMINAL 17 TO A D ISS I M I LAR GROUND OR NONGROUNDED CIRCUIT 5 TO SUPPLY I HOLD FEATURE TERMI NATE O Y MOUNTING CORD LEAD FROM F I RST MODULE ON TERMINAL 24 LEAD BECOMES SP LEAD AT EQUIPMENT 6 I F HOLD POSITION LAMP IS REQUIRED CONNECT G Y LAMP LEAD AND Y G ...

Page 5: ... 04 2012 14 35 56 Y S Y BR BR Y f J 0 Y Y O c v f J G BK BK G BR BK 81 BR S BK BK S s R R S BL BK BK BL f J o R R 0 G R iR G BR R R BR BR W W BR s w w s BL R R BL BL W W BL o w w o s lBL V 5 V BL l l BR V r e i R R R1 8 OR Bt BL SG R T B A H S OR Sl L LG R T B A H S OR I L LG R T B A1H1S OR 51 L LG R T B A1H S OR Sl L LG R T 6 A H S OR Sl L LG I R T OR B A1H15 OR 51 L LG TO lA IAI IA2 KTS A75A ONL...

Page 6: ...6 17 42 18 43 13 36 39 15 40 10 35 II 36 12 37 1 32 33 34 29 s 30 6 31 26 2 27 3 28 21 22 47 23 24 49 2S 50 A75A OR AIOOD CONNECTOR C t BLE 0 W B I ND CONN 2 IS Y Y 5 Bl Y Y BL D Y Y O G Y J BK G BR BK BK ml f J S R R S BL BK BK BL 0 BK BK D O R 5 R 0 G R R G BR R l W BR S W 5 t JJ IR BL BL W rJ BL o wl w o l l 5 BL V V BL V 0 G V V G fi R l V BR s v BZ BZI SPARE P6 R T A H S OR 51 l OR 56 LG OR 5...

Page 7: ... Y lY eRJ s v Y i BL Y Y BL 112 t l l t ol fG ll Y G G BK BK G jBR BK BK BR 5 BK jBK 5 S R R S BL BK fBK BL 0 BK BK 0 O R R 0 G R jR Gj s BR W W BR s w jw sl BL R jR Bl BL W s t Bl o w s W G SPARE SPAR SPARE se aBE R T B A H SOR 51 I LG R T B A H 5 OR 51 l LG R T 8 A1H1SOR 51 l LG R T B H SOR il l LG R T B A1H1SORSI l LG R T B A1H1SOR 51 l LG II 0 CQ CD Fig 2 Module and Connector Cable Arrangement...

Page 8: ...BLE BR Wl BINDER PLUG4 CONN4 I 19 l t 44 S Y 1 20 Y S I BL Y BL Y SPARE SPARE SPARE SPARE Y Rl 4l 1 Y B l T ___ _ Y O y l7 O tY 42 Y O A H S OR 51 1 8 G Y I OR S6 Y G 43 Y G LG OR 5 1 2 G BK 13 G BK BK G Fig 2 Module ond Connector Coble Arrangements Sheet 4 of 5 SSP 502 610 418 i04_197S 03 08 jpg Scanned by Frank Harrell Cowboy Frank Castle Rock Colorado Feb 04 2012 14 37 01 TO lA IAI IA2 OR 6A KT...

Page 9: ...ll BL R R BL BL Wl W 8L I w o G W W G 7 f 4 CONNECTOR CABLE A75A G W BINOER AI000 S W 8INOER 35 tR 51 BL BK II jBI BLj 36 0 BI J 12 81 0 37 O BI 7 32 R 0 B G Rl 33 IR G 9 IBR R 34 R BR 4 BB Wl 29 W BR 5 S W 30 lw sr 6 BL R 31 R Bll I BL WI SPAR SPARE SPARE SPARE R OR 66 1 OR LG4 8 6t 1SQBSl L 54 OR LIO LG SID OR LGIO R OR 63 T OR LG3 8 A H S OR 1 L 53 ORL9 LG 59 ORLG9 R OR LZ T OR LG2 B A H 5 OR 5...

Page 10: ...N ONE BUSY LAMP IS REQUI REO ONLY THE 6C KTU BUSY LAMP CONTROL CIRCUIT SHOWN IN FIG 5 MAY BE USED Fig 3 Statian Busy lamp Circuit Using Printed Wiring Board Assembly TABLE A lA I AI AND 1A2 CONVERSION 636CA TELEPHONE SET LEAD KEY HOLD KEY CHAINING PLUG CONTACT STRIP MODULE OR PLUG ARRANGE MENT V G V G R R R R R y G BR V V BR 1ST 2ND 1ST 2ND 1ST 2ND 3RD MOD MOD MOD MOD MOD MOD MOD 1Al 1A2 10 10 5 1...

Page 11: ...__ o __j GRD I I T c Jl GRD LEGEND PU PICKUP KEY H HOLD KEY LS LlNE SWITCH HSIA HEADSET JACK A L rBUSY LAMP NOTE 21 LG NOTES I Y BRI MOUNTING CORD LEAD DESIGNATED BL IS NOT USED 2 WHEN A LAMP IND ICATOR IS USED FOR BUSY LAMP EITHER A 51A IOV OR 52A 24V LAMP MAY BE USED IF THE LAMPS OF A KEY OR LAMP SOCKET INSTALLED IN A TELEPHONE SET ARE USED ONLY 51 A IOV LAMPS SHALL BE USED TO AVOID OVERHEATING ...

Page 12: ... 41 14 5 15 35 12 9 11 21 31 9 11 21 31 14 8 3rd 4th Mod 1A 5th Mod 1A1 1A2 1st 2nd 3rd Mod 10 12 31 14 5 15 12 45 9 11 21 14 9 11 21 14 41 8 1A 4th 5th Mod 1A1 1A2 1st 2nd Mod 10 12 21 14 5 12 35 45 9 11 14 31 9 11 14 31 41 8 1A 3rd 4th 5th Mod 1A1 1A2 1st Mod 1A 2nd 3rd 10 12 11 14 12 15 35 45 9 14 21 31 9 14 21 31 41 8 4th 5th Mod 1A Only 10 37t 13 5 15 35 45 37 11 21 31 37 11 21 31 41 18 Insul...

Page 13: ...9 18 39 30 39 30 39 30 39 30 39 1 When using converted 6th pickup button as common signaling key remove in sulate and store Y 0 mounting cord lead from terminal 39 2 If more than six signal keys are required replace 635G5C key with a 658A key If more than five private or intercom lines are required convert keys in 2nd 636CA or 4th 637DA module in same order Connect plug leads to terminal 39 to uti...

Page 14: ...ay Grd Note 4 Insulate and store Notes 1 Remove BR BK and BK BR slate plug leads from terminals 10 and 29 insulate and store 2 To individual line or common ringer circuit at equipment 3 To external ringer or buzzer Connect ringer or buzzer circuit to Bl Y Y BL connector cable leads at equipment 4 Connect T R and A leads from equipment and station to be cut off through contacts of auxiliary relay C...