EN 11
INSTALLATION
Discharge
The extractor hood WU11..PMM/WU90..PMM has 5 extraction settings:
up, left or right. The extractor is as standard used in the up position.
Alternatively, you can also turn the motor to direct the exhaust either
left or right:
• Unscrew the 4 screw fasteners of the motor and remove the motor.
• Unscrew the 4 screws from the grill (left or right).
• Place the grill over the top hole and attach it using the 4 screws.
• Place the motor tilted in the side hole and secure it using the
4 screws.
The WU11..PMX/WU15..PMX has 3 extraction settings. 2 connecting
pieces are supplied for this.
• 180 mm round piece for extraction upwards.
• 220 x 90 mm plate for extraction left or right.
If the exhaust is directed to the right or left of the unit, the cover plate
(packed with the unit as a separate item) can be used for sealing the
top exit. The profile (also packed separately) can be bent to meet the
connecting flange for the side exit.
Building-in dimensions
935
320
1120
480
235
45
1100
460
WU11..PMM
935
320
1120
480
125
45
1100
460
WU11..PMX
602
388
840
520
235
45
820
500
WU90..PMM
1156
398
1520
720
125
45
1500
700
WU15..PMX
Summary of Contents for WU11 PMM Series