EN 14
INSTALLATION
Discharge
The extractor hood WU11..PM has 3 extraction settings: up, left or
right. The extractor is as standard used in the up position. Alternatively,
you can also turn the motor to direct the exhaust either left or right:
• Unscrew the 4 screw fasteners of the motor and remove the motor.
• Unscrew the 4 screws from the grill (left or right).
• Place the grill over the top hole and attach it using the 4 screws.
• Place the motor tilted in the side hole and secure it using the
4 screws.
The WU11..PXWU15..PX has 3 extraction settings. 2 connecting pieces
are supplied for this.
• 180 mm round piece for extraction upwards.
• 220 x 90 mm plate for extraction left or right.
If the exhaust is directed to the right or left of the unit, the cover plate
(packed with the unit as a separate item) can be used for sealing the
top exit. The profile (also packed separately) can be bent to meet the
connecting flange for the side exit.
Building-in dimensions
1156
396
1520
720
125
45
1500
700
935
320
1120
480
235
45
1100
460
935
320
1120
480
125
45
1100
460
WU11..PM
WU11..PX
WU15..PX