Operating instructions ATAG Q-Solar
Operating instructions ATAG Q-Solar
4
In case you smell gas:
-
Do not use naked flames! Do not smoke!
-
Do not operate electrical switches for lights or
any other appliance.
-
Do not use a telephone
-
Turn off gas supply at meter
-
Open windows and doors
-
Notify any persons in the building and leave the
building at once.
-
Call Gas company or installer only when
outside the building
Protection for corrosion
Do not use any sprays, chlorine containing agents,
solvents, paint etc. around the boiler or around the
air intake supply entrance of the boiler. These
substances have negative influences on the boiler
and can lead to corrosion resulting in failure of the
boiler.
Checking the water pressure
Check the water pressure in the central heating
installation regularly.
Use only potable water for filling.
Additives only after clearance by ATAG.
Contact your installer in case of doubt.
Safety
17
Selection
Type of installation
Flow water
temperature
01
Radiators; air heating; convectors
85°C
02
Radiators with large surface areas or under floor heating as
additional heating
70°C
03
Under floor heating with radiators as additional heating
60°C
04
full under floor heating
50°C
= factory setting
Adjusting the type of installation
The boiler is designed in such a way that it will
adjust itself automatically to what is necessary for
a normal heating system. In some cases the
installation may have convectors or complete
underfloor heating.
One can easily choose heating installation
adjustments appropriate for the system such as
maximum water-flow temperature or for the
warming up of the installation after a night period.
Adjustment goes as follows:
-
Press (from the Technical) reading the Mode
key once;
-
Press the Step key twice;
The display will show 2 01.
-
Press the + or the - key to alter the type of
installation according to the table below;
-
Press the Store key to confirm the setting;
The display will flash once.
-
Press the Mode key once;
The display will show StbY for a short while and
will return to the Technical reading.
+
Store
Mode
Step
Reset
-
When a type of installation has been chosen with a low water-flow temperature
it is possible that in case of a severe winter period the temperature of the
heating system will need to be increased slightly. In such situations the
installation choice may need to be changed, so that a higher flow temperature
can be chosen. This adjustment would normally be carried out by your installer
during the installation and commissioning.