In case you smell gas:

-

Do not use naked flames! Do not smoke!

-

Do not operate electrical switches for lights or
any other appliance.

-

Do not use a telephone

-

Turn off gas supply at meter

-

Open windows and doors

-

Notify  any persons in the building and leave the
building at once.

-

Call Gas company or installer only when
outside the building

Protection for corrosion

Do not use any sprays, chlorine containing agents,
solvents, paint etc. around the boiler or around the
air intake supply entrance of the boiler. These
substances have negative influences on the boiler
and can lead to corrosion resulting in failure of the
boiler.

Checking the water pressure

Check the water pressure in the central heating
installation regularly.
Use only potable water for filling.
Additives only after clearance by ATAG.
Contact your installer in case of doubt.

Safety

17

Selection

Type of installation

Flow water

temperature

01

Radiators; air heating; convectors

85°C

02

Radiators with large surface areas or under floor heating as
additional heating

70°C

03

Under floor heating with radiators as additional heating

60°C

04

full under floor heating

50°C

= factory setting

Adjusting the  type of installation

The boiler is designed in such a way that it will
adjust itself automatically to what is necessary for
a normal heating system. In some cases the
installation may have convectors or complete
underfloor heating.
One can easily choose heating installation
adjustments appropriate for the system such as
maximum water-flow temperature or for the
warming up of the installation after a night period.
Adjustment goes as follows:

-

Press (from the Technical) reading the Mode

key once;

-

Press the Step key twice;

The display will show  2  01.

-

Press the + or the - key to alter the type of

installation according to the table below;

-

Press the Store key to confirm the setting;

The display will flash once.

-

Press the Mode key once;

The display will show StbY  for a short while and

will return to the Technical reading.

+

Store

Mode

Step

Reset

-

When a type of installation has been chosen with a low water-flow  temperature
it is possible that in case of a severe winter period the temperature of the
heating system will need to be increased slightly. In such situations the
installation choice may need to be changed, so that a higher flow temperature
can be chosen. This adjustment would normally be carried out by your installer
during the installation and commissioning.

Summary of Contents for Q-Solar

Page 1: ...tor for UK ATAG Heating UK Ltd Unit 3 Beaver Trade Park Quarry Lane Chichester West Sussex PO19 8NY Phone 01243 815 770 Fax 01243 839 596 E mail info atagheating co uk Internet www atagheating co uk Ditributor for Ireland Total Energy Management Ltd Unit 9 Ballybritt Industrial Estate Monivea Road Galway Ireland Phone 091 769174 Fax 091 769485 E mail info tem ie Internet www tem ie ...

Page 2: ... Reset key 7 The boiler display 8 Water pressure in the central heating system 9 Replenishing the central heating 10 Turning the boiler off 12 Error maintenance and warranty 13 Adjustments 14 Important It is in your own interest that we should know that you have an ATAG boiler Please fill out the warranty card completely and send it back to us Then we can be fully at your service 19 ...

Page 3: ...servicing instructions manual for the installer Readthismanualfullybeforeoperatingtheboiler In case of doubt or errors contact your installer ATAG Heating reserves the right to change the specifications and dimensions without prior notice Work on the boiler must be carried out by a competent person Ref Gas Safety Installation and Use using correctly calibrated instruments with current test certifi...

Page 4: ...nal heating 60 C 04 full under floor heating 50 C factory setting Adjusting the type of installation The boiler is designed in such a way that it will adjust itself automatically to what is necessary for a normal heating system In some cases the installation may have convectors or complete underfloor heating One can easily choose heating installation adjustments appropriate for the system such as ...

Page 5: ...s soon as this temperaturedifferencehasdroppedtoapprox 2 C The pump also switches off automatically as soon asthecylinderhasreachedatemperatureof80 C The controller allows the pump to restart once the temperature of the cylinder has dropped to 75 C Room sealed boiler The boiler retreives its combustionairfromoutside then discharges the flue gasses to the outside Condensing Retrieves heat from the ...

Page 6: ...ertotheuser manual ATAG BrainQ Example SEDBUK ClassA Normally the pipes between absorber and cylinder are insulated However it needs your attention that the pipes during operation can be extreemly hot 120 C 15 Error maintenance and warranty If a fault is detected the boiler will be blocked This will be reflected by an alternate display of Good with an Eof Error or a BL of Blocking and a number cod...

Page 7: ...od Adjust the thermostat to the holiday period See the BrainQ user manual The hot water facility can beswitchedoffbymeansoftheprogramkey on the control panel Re setting the central heating system Switch off the three program keys when these are activated Switch off the power supply When the boiler is being drained one should take into account that a part of the heating water will remain in the boi...

Page 8: ...D s On the left side of the boiler there is a small door Throughthetransparentpartyoucanseetheboiler statusonthedisplay Afteropeningthisdooryouwill find the function keys On the right side of the door you will find an instruction card in a sleeve with an explanation of the display messages and function keys This is described below 13 The boiler will not function directly The automatic de aeration ...

Page 9: ...ntact your installer 12 Replenishing the central heating system The central heating installation needs to be filled with potable drinking water For topping up the installation you use the filling loop according to the following procedure If in any doubt please contact your dealer 1 Switch all functions off heating DHW and pump 2 Briefly push the STEP button P x x water pressure in bar 3 Slowly ope...

Page 10: ...essure in bar If a fault is found the same is shown as described under TheGoodreading Selecting the Technical or Good reading Press the Step key for 5 seconds The display will change from the Good reading to the technical reading or vice versa 11 Water pressure in the central heating system The installation will function optimally with a water pressure of between 1 5 and 1 7 bar Ifthewaterpressure...

Reviews: