Operating Instructions
AT
AG QR-Series
9
6
Main functions of the control panel
Button
Action
Procedure
Display / Function
Setting up the
required
room temperature
HC2 jointly with HC1
Turn the rotating button left or right
Turn the rotating button again for
storing with OK button
or wait for 5 sec.
or push
comfort target value with blinking temperature display
blinking temperature display in steps of 0.5° centigrade, from 10.0 to 30°C
Comfort value active
Comfort value not active
- Basic display appears after 3 sec.
Only works in
combination with
QAA55, NOT with
OT/On-Off
Setting the required
room temperature
for HC1 or HC2
or
2nd HC independent of HC1
Turn rotating button left/right
Then push OK
Turn rotating button left/right
Save with OK button
or wait for 5 sec.
or push
Select heating circuit
Heating circuit active
blinking temperature display in steps of 0.5° centigrade, from 10.0 to 30°C
Comfort target value active
Comfort target value not active
- Basic display appears after 3 sec.
Switching warm
water operations
ON or OFF
Push button
Warm water operation ON / OFF
(segmented bar under symbol for warm water visible/invisible)
-
ON: Warm water preparation according to switching program
-
OFF: No warm water preparation
-
Safety function active
DHW timer program
via external
controller is leading
Change operating
mode
Factory setting
1 x short push of button and then
once more, short push of button
once more, short push of button
Automatic operating mode ON, with:
-
heating operation according to timer program
-
Temperature target values according to heating program
-
Safety function active
-
Summer/Winter - automatic switching active
-
ECO functions active
(segmented bar under corresponding symbol visible)
Continuous COMFORT heating ON, with:
-
Heating operation without timer program, at comfort target value
-
Safety function active
Continuous REDUCED heating ON, with:
-
Heating operation without timer program, at reduced target value
-
Safety function active
-
Summer/Winter - automatic switching active
-
ECO functions active
Automatic safety mode ON, with:
-
Heating operations switched off
-
Temperature according to frost protection value
-
Safety function active
Only works in
combination with
QAA55, NOT with
OT/On-Off
Control stop
function
1 x push button (> 3 sec)
push button once more (> 3 sec)
304: Control stop function
Set target value
Basic display appears after 3 sec.
Button
Action
Procedure
Display / Function
Display of various
information
1 x push button
push button again
push button again
Push button
INFO section is displayed
- Boiler status
- Room temperature
- Room temperature minimum
- Warm water status
- Room temperature maximum
- Status heating circuit 1 - Outdoor temperature
- Status heating circuit 2 - Minimum outdoor temperature
- Maximum outdoor temperature
- Time / date - Water temperature 1
- Error message
- Boiler temperature
- Maintenance report
- Flow temperature
(Display of the information lines depends on the configuration)
Back to basic display; INFO segment is suppressed
Operating mode
according to
target values that
are
set manually
Change of the
factory setting
for boiler
temperature
short push of button
short push of button
short push of button
Rotating button turn -/+
short push of button
short push of button
short push of button
Manual operating mode ON
(spanner symbol is visible)
- Heating operations at preset boiler temperature (factory setting = 60°C)
301: Manual operation mode
Set target value for manual
operation?
Blinking temperature display
Set required target value
Boiler status
Manual operating mode OFF (spanner symbol disappears)
De-aeration function
1 x push button (> 3 sec)
push button once more (> 3 sec)
312: De-aeration function ON
De-aeration function OFF
Activation of
chimney sweep
function
Push button (> 3 sec)
push button once more (> 3 sec)
Chimney sweep function ON
Chimney sweep function OFF
Short-term
reduction of room
temperature at
QAA75 / 78
Push button
push button again
Heating at reduced target value
Heating at comfort target value
Only works in
combination with
QAA55, NOT with
OT/On-Off
RESET
Reset button
Push button (< 3 sec.) push button
again > 3 sec.
Facility is manually locked, unreleased equipment is unlocked, alarm bell
disappears
= Confirmation
= Abort or back to basic display
MAY ONLY BE OPERATED BY A QUALIFIED INSTALLER!