Installation instructions S-HR series page 13
In cold and/or humid weather water vapour may condense
on leaving the flue terminal. The effect of such ‘steaming’
must be considered.
The terminal must not be located in a place where it is
likely to cause a nuisance.
For protection of combustibles, refer to IS 813 section
9.10.1. where the terminal is less than 2m (6.6ft) above
a pavement or platform to which people have access
(including) any balcony or flat roof the terminal must be
protected by a guard of durable material.
A suitable guard is available from the country distributor.
Where a terminal is fitted below a window
which is hinged at the top, and where the
hinge axis is horizontal, and the window
opens outwards, the terminal shall be 1m
below the bottom of the window opening.
If the boiler is to be located under stairs, a
smoke alarm meeting the requirements of I.S.
409 or equivalent must be fitted.
The flue must be terminated in a place not
likely to cause a nuisance.
For horizontal sections, the outlet system should always
be fitted on an incline (30 mm/m) sloping down towards
the appliance so that no condensation water is able to
accumulate in the outlet system. The chances of icicles
forming on the roof outlet is minimised by causing the
condensation water to run back towards the appliance.
In the case of horizontal outlets the inlet system should
be fitted on an incline sloping down towards the outside
to prevent rainwater from coming in.
Fitting an additional condensation collection device in
the outlet system is surplus to requirement.
The appliance produces a white wisp of condensation.
This wisp of condensation is harmless, but can be found
to be unpleasant, particularly in the case of outlets in
outside walls.
The appliance is not suitable as an "open"
appliance. This means that combustion air
should always be obtained through a direct
connection.
For further information regarding the supply
range of the exhaust and supply system
please contact the country distributor.
Summary of Contents for Blauwe Engel S-HR 15
Page 2: ......
Page 15: ...Installation instructions S HR series page 15 electrical connecting diagram figure 11...
Page 31: ...Installation instructions S HR series page 31 19 CE Certificate United Kingdom...
Page 32: ...Installation instructions S HR series page 32 20 CE Certificate Ireland...
Page 33: ......
Page 34: ......
Page 35: ......