background image

3

DM481

English

1.  Read  these  instructions  before  operating  this

apparatus.

2.  Keep these instructions for future reference.

3.  Heed all warnings to ensure safe operation.

4.  Follow all instructions provided in this document.

5.  Do not use this apparatus near water or in locations 

where condensation may occur.

6.  Clean only with dry cloth. Do not use aerosol or liquid 

cleaners. Unplug this apparatus before cleaning.

7.  Do not block any of the ventilation openings. Install 

in accordance with the manufacturer’s instructions.

8.  Do not install near any heat sources such as radiators, 

heat registers, stoves, or other apparatus (including 

.

9.  Do not defeat the safety purpose of the polarized or

grounding-type plug. A polarized plug has two blades 
with one wider than the other. A grounding type plug 
has two blades and a third grounding prong. The wide
blade or the third prong is provided for your safety. If
the provided plug does not  into your outlet, consult 
an electrician for replacement of the obsolete outlet.

10. Protect  the  power  cord  from  being  walked  on  or 

pinched particularly at plug, convenience receptacles,
and the point where they exit from the apparatus.

11.  Only  use  attachments/accessories 

 by  the 

manufacturer.

12. Use  only  with  a  cart,  stand,  tripod,  bracket,  or

table 

  by  the  manufacturer,  or  sold  with

the  apparatus.  When  a  cart  is  used,  use  caution 
when  moving  the  cart/apparatus
combination to avoid injury from tip-
over.

13. Unplug this apparatus during lighting 

storms  or  when  unused  for  long 
periods of time.

14. Refer  all  servicing  to

service    personnel.

Servicing is required when the apparatus has been 
damaged in any way, such as power-supply cord or
plug is damaged, liquid has been spilled or objects 
have  fallen  into  the  apparatus,  the  apparatus  has 
been exposed to rain or moisture, does not operate 
normally, or has been dropped.

IMPORTANT SAFETY INSTRUCTIONS

CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK,

DO NOT REMOVE COVER (OR BACK)

NO USER SERVICEABLE PARTS INSIDE

REFER SERVICING TO QUALIFIED PERSONNEL

The  lightning  flash  with  arrowhead  symbol,  within  an
equilateral  triangle,  is  intended  to  alert  the  user  to  the
presence  of  uninsulated “dangerous  voltage” within  the 
product’
magnitude to constitute a risk of electric shock to persons.

The exclamation point within an equilateral triangle is in-
tended to alert the user to the presence of important operat-
ing and maintenance (servicing) instructions in the literature 
accompanying the appliance.

WARNING:

To reduce the risk of 

 or electric shock, do 

not expose this apparatus to rain or moisture.

CAUTION:

Use of controls or adjustments or performance

of  procedures  other  than  those 

  may  result  in

hazardous radiation exposure.

The apparatus shall not be exposed to dripping or splashing and that no objects

with liquids, such as vases,

shall be placed on the apparatus. The MAINS plug is used as the disconnect device, the disconnect device shall
remain readily operable. 

Warning

: the user shall not place this apparatus in the

area during the operation so that the mains switch

can be easily accessible. 

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

Summary of Contents for DM481

Page 1: ...User s Manual Manual del Usuario 8 Channel Rackmount Mixer DM481 ...

Page 2: ...DEL PANEL FRONTAL 10 DESCRIPCIÓN DEL PANEL POSTERIOR 10 ESPECIFICACIONES 12 DIMENSIONS DIMENSIONES 13 APPLICATION APLICACIONES 14 Asystems reserves the right to alter information provided in this document without prior notice Asystems se reserva el derecho de mejorar o alterar cualquier información provista dentro de este documento sin previo aviso V1 0 21 07 2017 CONTENTS CONTENIDO APPENDIX ...

Page 3: ...uring lighting storms or when unused for long periods of time 14 Refer all servicing to service personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped IMPORTANT SAFETY ...

Page 4: ...equired This may include line level devices as well as microphones and or guitars keyboards etc 4 Plug any necessary equipment into the DM481 s output jack and pre fader output These outputs can be sent to various devices such as amplifiers active speakers or monitors signal processors and or recording devices 5 Plug the supplied AC cable into the AC inlet on the back of the device ensuring the lo...

Page 5: ...isable to turn the level control down somewhat to reduce the signal s level and avoid distortion 3 Mute Buttons These buttons affectively mute the corresponding channels ensuring signals received by the channels are not sent onto the main mixing bus 4 Channel Level Controls This control will alter the signal level that is sent from the corresponding channel to the main mixing bus 5 Master Level Co...

Page 6: ...utput the final line level signal sent from the main mixing bus The primary purpose of this jack is to send the Main output to external devices such as amplifiers active speakers as well as other mixers PA systems and a wide range of other possible signal processors 12 48V Phantom Power These switches allow you to individually elect which channel s microphone input jack to active phantom power on ...

Page 7: ...utput 20Hz 20KHz 0 1 dB 20Hz 60KHz 0 3 dB S N ratio ref to 4 106 dB Microphone Preamp E I N 150 ohms terminated max gain 129 5 dBm CMRR 1 KHz 60dBu Gain at maximum 80 dB Maximum Level Mic Preamp Input 10 dBu All Other Input 22 dBu Main Output 22 dBu Impedance Mic Preamp Input 1 4 K ohms Unbalanced Line in 12 K ohms AUX Bus In 10 K ohms Main Output 100 ohms Prefader Out 100 ohms Power Physical Powe...

Page 8: ...8 DM434 Español ...

Page 9: ...te todos los instumentos necesarios y todo el equipo en las entradas de la mixer como sea necesario Esto puede incluir dispositivos de nivel de línea así como también micrófonos y o guitarras teclados etc 4 Conecte todo el equipo necesario en los jacks de salida de la PM 801 y salida de pre fader Estas salidas pueden ser enviadas a varios dispositivos como amplificadores altavoces activos o monitor...

Page 10: ...ente Si parpadea se aconseja bajar el control de alguna manera para evitar la distorsión 3 Botones de Mute Estos botones cancelan efectivamente los canales correspondientes asegurando que las señales recibidas por los canales no serán enviados al bus de mezcla principal 4 Controles de Nivel de Canal Este control alterara el nivel de la señal que es enviado del canal correspondiente al bus de mezcl...

Page 11: ... es de enviar la salida de principal a dispositivos externos tales como amplificadores altavoces activos sistemas PA y una gran gama de otros posibles procesadores de señal Identificación de Pin electropositivo y negativo para conectar pines con tierra pueden ser encontrados debajo de la entrada jack 12 Fuente Fantasma a 48V Estos selectores te permiten seleccionar individualmente qué canal de ent...

Page 12: ...20Hz 60KHz 0 3 dB Relación S R ref a 4 106 dB Preamplificador de Mic E I N 150 ohms terminados ganan máx 129 5 dBm CMRR 1 KHz 60dBu Gananacia al máximo 80 dB Nivel Máximo Entrada del Preamplificador de Micrófono 10 dBu Todas las demás Entradas 22 dBu Salida Principal 22 dBu Impedancia Entrada de Preamplificador de Micrófono 1 4 K ohms Entrada de Línea Desbalanceada 12 K ohms Entrada de Buas Aux 10...

Page 13: ...13 DM434 Appendix DIMENSIONS DIMENSIONES All measurements are shown in mm inches Todas las medidas están mostradas en mm pulgadas 44 mm 1 7 483 mm 19 ...

Page 14: ...APPLICATION APLICACIONES GRABADOR DE DAT DAT RECORDER MEZCLADORA MIXER MIC VOCAL VOCAL MIC MAQUINA DE TAMBOR DRUM MACHINE DM481 MIC VOCAL VOCAL MIC PROCESADOR PROCESSOR GUITARRA ELECTRICA ELECTRIC GUITAR TECLADO KEYBOARD ...

Page 15: ...15 DM434 Appendix NOTES ...

Page 16: ...www asystems sys com ...

Reviews: