Page 18
Draft
Rev. AX5
AdvanTag 9100 Technical Manual
Chapter 2: Theory of Operation
Data Storage—AdvanTag Reader
a
CID_DISPLAY
ON = Enable
OFF= Disable
CID_NP_ASCII
ON = Enable
OFF= Disable
CID_ERROR
ON = Enable
OFF= Disable
CID_JUSTIFY
R = Right
L= Left
CID_PAD
NUL = 0x00
ZERO = 0x30
Configuration
(Applicable only to version 21A
and later)
01 through 31
ENABLE_EVENTS
Enable Events (Pod or Operator
arrival/removal, and powerup.
ON = Event will be generated.
OFF = Events will not be generated.
Default = ON
EXTENDEDSSACK
(Applicable only to version 20C
and later)
Enables the extended error codes in SSACK.
The SEMI standard specifies only five codes
(NO, EE, CE, HE, and TE). When this option
is ON, up to 100 error codes might be
generated. Please see SSACK for all error
code.
ON = All error codes generated.
OFF= Only SEMI standard error codes
generated
HardwareRevisionLevel
Applicable only to version 21A
and later
Subsystem Hardware Rev. of Upstream
Controller OR Head (as applicable)
Up to 8 bytes
HeadID
(Applicable only to version 21A
and later)
Returns the HeadID or TargetID
Two digits
HeadStatus
(Applicable only to version 21A
and later)
IDLE or MANT
HSMS_IP
(SECS only)
HSMS IP address (Passive Connection)
HSMS_PORT
(SECS only)
HSMS Port address (Passive Connection)
HWREV
Same as HardwareRevisionLevel
T
ABLE
3
Attribute Values (ECID and SVID)
Attribute
Description and Limits or Values
Summary of Contents for Advantag 9100
Page 5: ...Page iv Draft Rev AX5 AdvanTag 9100 Technical Manual a ...
Page 7: ...Page vi Draft Rev AX5 AdvanTag 9100 Technical Manual a ...
Page 11: ...Page x Draft Rev AX5 AdvanTag 9100 Technical Manual Table of Contents a ...
Page 13: ...Page xii Draft Rev AX5 AdvanTag 9100 Technical Manual List of Figures a ...
Page 15: ...Page xiv Draft Rev AX5 AdvanTag 9100 Technical Manual List of Tables a ...
Page 19: ...Page 4 Draft Rev AX5 AdvanTag 9100 Technical Manual Safety Tags a ...
Page 49: ...Page 34 Draft Rev AX5 AdvanTag 9100 Technical Manual Troubleshooting Chart a ...