Service Manual
PA246Q
10
2.5 Transportation
Item
Condition
Spec
OK N.A Remark
Vibration
Unpacked, Non-Operating 20 Hz, 0.0185 g
2
/Hz
200 Hz, 0.0185 g
2
/Hz
(Duration: 5 min Per AXIS)
√
Package Test
√
(1)Random Vibration
Package, Non-Operating 1Hz, 0.0001 g
2
/Hz
4 ~100 Hz, 0.0001 g
2
/Hz
200 Hz, 0.001 g
2
/Hz
(Equivalent to 1.15 Grms)
(Duration: 30 min Per
surface on Z Axis)
√
(2)Drop
Package, Non-Operating
91 cm Height
(2 corners, 2 edges, 6
faces)
√
2.6 Electrostatic Discharge Requirements
Item
Condition
Spec
OK N.A Remark
Electrostatic Discharge
IEC801-2 standard
Contact: 8KV
Air: 15KV
√
2.7 Reliability
Item
Condition
Spec
OK N.A Remark
MTBF Prediction
Refer to Telcordia
(Bellcore)
≧
80,000 Hours (goal)
√
Excluding the
LCD, CCFL
CCFL Life time
at 25 °C
2
°C
≧
40,000 Hours (SA)
√
See Note
Note:
The lifetime of LED is defined as the time when LED packages continue to operate under the conditions at Ta
= 25 ±2 and I= (20)mA (per chip) until the brightness becomes _ 50% of its original value.
Summary of Contents for PA246Q
Page 8: ...Service Manual PA246Q 11 2 8 User s hardware control definition ...
Page 22: ...Service Manual PA246Q 25 5 Schematic Diagram 5 1 Power Board ...
Page 23: ...Service Manual PA246Q 26 5 2 Control Board ...
Page 24: ...Service Manual PA246Q 27 5 3 Interface Board ...
Page 25: ...Service Manual PA246Q 28 ...
Page 26: ...Service Manual PA246Q 29 ...
Page 27: ...Service Manual PA246Q 30 ...
Page 28: ...Service Manual PA246Q 31 ...
Page 29: ...Service Manual PA246Q 32 6 PCB layout 6 1 Power Board ...
Page 30: ...Service Manual PA246Q 33 6 2 Control Board 6 3 Interface Board ...
Page 35: ...Service Manual PA246Q 54 11 3 Check Scalar ...
Page 36: ...Service Manual PA246Q 55 11 4 Check LCD Module ...
Page 40: ...Service Manual PA246Q 59 11 8 Check PFC Function ...
Page 41: ...Service Manual PA246Q 60 12 Exploded View ...
Page 42: ...Service Manual PA246Q 61 ...
Page 45: ...Service Manual PA246Q 64 Photos of Recommended Parts List 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 ...