background image

 

 

Appendix B – I/O Information 

 

110

 

Fan

les

s E

mb
ed

ded

 Bo

PC

 

 

 

BO
XE

R-

6852

 

 

 

 

Summary of Contents for Aaeon BOXER-6852

Page 1: ...Last Updated April 7 2016 BOXER 6852 Fanless Embedded Box PC User s Manual 2nd Ed ...

Page 2: ...ded in this manual is intended to be accurate and reliable However the original manufacturer assumes no responsibility for its use or for any infringements upon the rights of third parties that may result from its use The material in this document is for product information only and is subject to change without notice While reasonable efforts have been made in the preparation of this document to a...

Page 3: ...ed trademark of Microsoft Corp Intel Pentium Celeron and Xeon are registered trademarks of Intel Corporation Core Atom are trademarks of Intel Corporation ITE is a trademark of Integrated Technology Express Inc IBM PC AT PS 2 and VGA are trademarks of International Business Machines Corporation All other product names or trademarks are properties of their respective owners ...

Page 4: ...the following items have been shipped Item Quantity BOXER 6852 1 Wallmount bracket 2 Screw Package 1 RAM Thermal Pad 1 Phoenix power connector 1 Product CD with User s Manual in pdf and drivers 1 If any of these items are missing or damaged please contact your distributor or sales representative immediately ...

Page 5: ...as detailed descriptions and explanations on the product s hardware and software features if any its specifications dimensions jumper connector settings definitions and driver installation instructions if any to facilitate users in setting up their product Users may refer to the AAEON com for the latest version of this document ...

Page 6: ...y transient over voltage 7 Always disconnect this device from any AC supply before cleaning 8 While cleaning use a damp cloth instead of liquid or spray detergents 9 Make sure the device is installed near a power outlet and is easily accessible 10 Keep this device away from humidity 11 Place the device on a solid surface during installation to prevent falls 12 Do not cover the openings on the devi...

Page 7: ...trusion to the device iii Exposure to moisture iv Device is not working as expected or in a manner as described in this manual v The device is dropped or damaged vi Any obvious signs of damage displayed on the device 18 DO NOT LEAVE THIS DEVICE IN AN UNCONTROLLED ENVIRONMENT WITH TEMPERATURES BEYOND THE DEVICE S PERMITTED STORAGE TEMPERATURES SEE CHAPTER 1 TO PREVENT DAMAGE ...

Page 8: ...explosion if the battery is incorrectly replaced Replace only with the same or equivalent type recommended by the manufacturer Dispose of used batteries according to the manufacturer s instructions and your local government s recycling or disposal directives Attention Il y a un risque d explosion si la batterie est remplacée de façon incorrecte Ne la remplacer qu avec le même modèle ou équivalent ...

Page 9: ...ded Box PC Industrial System 部件名称 有毒有害物质或元素 铅 Pb 汞 Hg 镉 Cd 六价铬 Cr VI 多溴联苯 PBB 多溴二苯醚 PBDE 印刷电路板 及其电子组件 外部信号 连接器及线材 外壳 中央处理器 与内存 硬盘 电源 O 表示该有毒有害物质在该部件所有均质材料中的含量均在 SJ T 11363 2006 标准规定的限量要求以下 X 表示该有毒有害物质至少在该部件的某一均质材料中的含量超出 SJ T 11363 2006 标准规定的限量要求 备注 一 此产品所标示之环保使用期限 系指在一般正常使用状况下 二 上述部件物质中央处理器 内存 硬盘 电源为选购品 ...

Page 10: ...yl Ethers PBDE PCB Other Components Wires Connectors for External Connections Chassis CPU RAM Hard Disk PSU O The quantity of poisonous or hazardous substances or elements found in each of the component s parts is below the SJ T 11363 2006 stipulated requirement X The quantity of poisonous or hazardous substances or elements found in at least one of the component s parts is beyond the SJ T 11363 2...

Page 11: ...lection JP5 10 2 2 6 COM2 Ring Function Selection JP6 10 2 2 7 COM1 Ring Function Selection JP7 11 2 2 8 COM4 Function Mode Selection JP8 11 2 2 9 COM3 Function Mode Selection JP9 11 2 2 10 COM4 Termination Selection DCD4 JP10 11 2 2 11 COM4 Termination Selection DTR4 JP11 12 2 2 12 COM3 Termination Selection DCD4 JP12 12 2 2 13 COM3 Termination Selection DTR4 JP13 12 2 2 14 Clear COMS1 Jumper CN2...

Page 12: ...6 24 2 3 17 MiniCard Slot Full MiniCard CN17 25 2 3 18 MiniCard Slot Half MiniCard CN18 27 2 3 19 PS 2 Keyboard Mouse Combo Port CN19 29 2 3 20 PCH Digital IO Port CN20 29 2 3 21 UIM Card Socket CN21 30 2 3 22 Digital IO Port CN22 30 2 3 23 LPC Port CN26 31 2 3 24 USB2 0 Port 8 and 9 Wafer BOX Optional CN29 32 2 3 25 USB3 0 Wafer BOX Optional CN30 32 2 3 26 External Power Input CN31 33 2 3 27 LAN ...

Page 13: ... BIOS Setup 54 3 3 Setup Submenu Main 55 3 4 Setup Submenu Advanced 56 3 4 1 F81866 Super IO Configuration 57 3 4 1 1 F81866 Super IO Configuration Serial Port 1 Configuration 58 3 4 1 2 F81866 Super IO Configuration Serial Port 2 Configuration 59 3 4 1 3 F81866 Super IO Configuration Serial Port 3 Configuration 60 3 4 1 4 F81866 Super IO Configuration Serial Port 4 Configuration 61 3 4 1 5 F81866...

Page 14: ...5 1 Chipset PCH IO Configuration 75 3 5 2 Chipset System Agent SA Configuration 77 3 5 2 1 System Agent SA Configuration Memory Configuration 78 3 6 Setup submenu Boot 79 3 6 1 Boot BBS Priorities 80 3 7 Setup submenu Security 81 3 8 Setup submenu Save Exit 82 Chapter 4 Drivers Installation 83 4 1 Product CD DVD 84 Appendix A Watchdog Timer Programming 91 A 1 Watchdog Timer Initial Program 92 Appe...

Page 15: ...Fanless Embedded Box PC BOXER 6852 Chapter 1 Chapter 1 Product Specifications ...

Page 16: ...ard CFast slot x 1 2 5 SATA HDD SSD drive bay x 1 Rear I O Panel 3 pin terminal block x 1 DB 9 for RS 232 x 2 DB 9 for RS 232 422 485 x 2 isolated USB2 0 type A x 2 USB3 0 type A x 2 DB 15 for VGA x 1 DVI D x 1 HDMI 1 4a x 1 RJ 45 for 10 100 1000Base TX x 2 Front I O Panel Power button x 1 DB 9 for RS 232 x 2 CFast slot x 1 SIM slot x 1 USB2 0 typeA x 2 Line out x 1 SMA Antenna holes x 2 Front Ind...

Page 17: ... Windows Embedded Standard 8 Linux kernel 2 6 x or above Linux Red Hat Mechanical Construction Rugged aluminum chassis Mounting Wallmount Dimension W x H x D 264 16 x 193 5 x 109 3 mm 10 4 x 7 62 x 4 3 Gross Weight 5 Kg 11 lb Environmental Operating Temperature 20 60 C 4 140 F with 0 5 m s airflow HDD CFast compliance to IEC 68 2 14 Storage Temperature 20 70 C 4 158 F Operating Humidity 5 95 40 C ...

Page 18: ...ions 4 Fanless Embedded Box PC BOXER 6852 1 Grms 5 500 Hz Operation HDD Anti Shock 50 G peak acceleration 11 msec duration CFast 20 G peak acceleration 11 msec duration HDD EMC CE FCC Class A Power Supply DC Input 9 30 V AT or ATX ...

Page 19: ...Fanless Embedded Box PC BOXER 6852 Chapter 2 Chapter 2 Hardware Information ...

Page 20: ...Chapter 2 Hardware Information 6 Fanless Embedded Box PC BOXER 6852 2 1 Dimensions Chassis ISOLATION D ...

Page 21: ...Chapter 2 Hardware Information 7 Fanless Embedded Box PC BOXER 6852 PCI Card ...

Page 22: ...ht Lightness Control Mode Selection JP3 LVDS Port Backlight Control Inverter VCC Selection JP4 LVDS Port Operating VDD Selection JP5 AT ATX Control Selection JP6 COM2 Ring Function Selection JP7 COM1 Ring Function Selection JP8 COM4 Function Mode Selection JP9 COM3 Function Mode Selection JP10 COM4 Termination Selection DCD4 JP11 COM4 Termination Selection DTR4 JP12 COM4 Termination Selection DCD4...

Page 23: ...OXER 6852 2 2 1 Front Panel Connector JP1 Pin Function 1 PWR_BTN 2 PWR_BTN 3 HDD_LED 4 HDD_LED 5 SPEAKER 6 SPEAKER 7 PWR_LED 8 PWR_LED 9 H W RESET 10 H W RESET 2 2 2 LVDS Port Backlight Lightness Control Mode Selection JP2 VR Mode Default PWM Mode 1 2 3 1 2 3 ...

Page 24: ... 2 2 3 LVDS Port Backlight Control Inverter VCC Selection JP3 12V 5V Default 2 2 4 LVDS Port Operating VDD Selection JP4 12V 3 3V Default 2 2 5 AT ATX Control Selection JP5 ATX AT Default 2 2 6 COM2 Ring Function Selection JP6 12V Ring Default 5V 1 2 3 1 2 3 1 2 3 1 2 3 ...

Page 25: ...lt 5V 2 2 8 COM4 Function Mode Selection JP8 RS 422 RS 232 Default RS 485 Driver Half Duplex RS 485 Receiver Half Duplex 2 2 9 COM3 Function Mode Selection JP9 RS 422 RS 232 Default RS 485 Driver Half Duplex RS 485 Receiver Half Duplex 2 2 10 COM4 Termination Selection DCD4 JP10 No Termination Default Termination With 120Ω ...

Page 26: ...n DTR4 JP11 No Termination Default Termination With 120Ω 2 2 12 COM3 Termination Selection DCD4 JP12 No Termination Default Termination With 120Ω 2 2 13 COM3 Termination Selection DTR4 JP13 No Termination Default Termination With 120Ω 2 2 14 Clear COMS1 Jumper CN23 Normal Default Clear CMOS 1 2 3 1 2 3 ...

Page 27: ...Chapter 2 Hardware Information 13 Fanless Embedded Box PC BOXER 6852 2 2 15 Clear COMS2 Jumper CN24 Normal Default Clear CMOS 1 2 3 1 2 3 ...

Page 28: ...DD CN5 USB2 0 Port 6 and 7 CN6 LVDS Port Inverter Backlight Connector CN7 UIM Card Sock Push Push type CN8 CFast Slot CN9 COM Port 6 Wafer BOX Optional CN10 COM Port 5 Wafer BOX Optional CN11 SATA2 0 Connector CN12 5V SATA Power Connector CN13 PSON Output CN14 PCIe Connector CN15 3 3V and 5V Output CN16 SATA2 0 Connector CN17 Mini Card Slot Full Mini Card CN18 Mini Card Slot Half Mini Card CN19 PS...

Page 29: ... BOX Optional CN30 USB3 0 Wafer BOX Optional CN31 Adapter Power in Connector CN32 LAN RJ 45 Dual USB3 0 USB2 0 CN33 HDMI Port CN34 LAN RJ 45 Dual USB2 0 CN35 COM Port 1 and 2 D SUB 9 CN36 COM Port 3 and 4 D SUB 9 CN37 External Power Input CN38 VGA DVI D Port LED1 LAN1 LED LED2 LED2 LED LED3 LAN2 LED ...

Page 30: ...anless Embedded Box PC BOXER 6852 2 3 1 Audio Connector CN1 Pin Pin name Signal Type Signal Level 1 MIC_L I O 2 MIC_R I O 3 GND GND 4 LIN_L I O 5 LIN_R I O 6 GND GND 7 LOUT_L I O 8 GND GND 9 LOUT_R I O 10 VDD_AUD PWR 2 3 2 LVDS Port CN2 ...

Page 31: ...FF 7 VDD_LVDS PWR 8 GND GND 9 LVDSA_DATA0 DIFF 10 LVDSA_DATA0 DIFF 11 LVDSA_DATA1 DIFF 12 LVDSA_DATA1 DIFF 13 LVDSA_DATA2 DIFF 14 LVDSA_DATA2 DIFF 15 LVDSA_DATA3 DIFF 16 LVDSA_DATA3 DIFF 17 LVDS_DDC_DATA DIFF 18 LVDS_DDC_CLK DIFF 19 LVDSB_DATA0 DIFF 20 LVDSB_DATA0 DIFF 21 LVDSB_DATA1 DIFF 22 LVDSB_DATA1 DIFF 23 LVDSB_DATA2 DIFF 24 LVDSB_DATA2 DIFF 25 LVDSB_DATA3 DIFF 26 LVDSB_DATA3 DIFF 27 VDD_LVD...

Page 32: ...GND 29 LVDSB_CLK DIFF 30 LVDSB_CLK DIFF 2 3 3 COM Port 5 and 6 D SUB9 CN3 Pin Pin Name Signal Type Signal Level 1 DCD5 IN 2 RX5 IN 3 TX5 OUT 4 DTR5 OUT 5 GND GND 6 DSR5 IN 7 RT5 OUT 8 CTS5 IN 9 RI5 IN 10 DCD6 IN 11 RX6 IN 12 TX6 OUT 13 DTR6 OUT 14 GND GND 15 DSR6 IN 16 RT6 OUT ...

Page 33: ...852 17 CTS6 IN 18 RI6 IN 2 3 4 5V 12V Output for SATA HDD CN4 Pin Pin Name Signal Type Signal Level 1 12V PWR 12V 2 GND GND 3 GND GND 4 5V PWR 5V 2 3 5 USB2 0 Port 6 and 7 CN5 Pin Pin Name Signal Type Signal Level 1 V5A_USB_6_7 PWR 2 USBD6 DIFF 3 USBD6 DIFF 4 GND GND ...

Page 34: ...ort Inverter Backlight Connector CN6 Pin Pin Name Signal Type Signal Level 1 VCC_LVDS_BKLT PWR 5V 12V 2 L_BKLTNESS OUT 3 GND GND 4 GND GND 5 LVDS_BKLTEN OUT 2 3 7 UIM Card Sock Push Push type CN7 Pin Pin Name Signal Type Signal Level C1 UIM_PWR1 I O C2 UIM_RST1 I O C3 UIM_CLK1 I O C5 GND GND C6 UIM_VPP1 I O C7 UIM_DAT1 I O DET1 GND GND ...

Page 35: ...Signal Type Signal Level S1 GND GND S3 CFast_TXN2_C DIFF S5 CFast_RXN2_C DIFF S7 GND GND PC2 GND GND PC4 NC PC6 NC PC8 NC PC10 NC PC12 NC PC14 3 3V PWR PC16 GND GND S1 GND GND S3 CFast_TXN2_C DIFF S5 CFast_RXN2_C DIFF S7 GND GND PC2 GND GND PC4 NC PC6 NC PC8 NC PC10 NC PC12 NC PC14 3 3V PWR PC16 GND GND ...

Page 36: ...t 6 Wafer BOX Optional CN9 Pin Pin Name Signal Type Signal Level 1 DCD I O DCD 2 DSR I O 3 RX I O 5V 4 RTS I O 5 TX I O 5V 6 CTS I O 7 DTR I O 8 RI PWR 5V 12V 9 GND GND 2 3 10 COM Port 5 Wafer BOX Optional CN10 Pin Pin Name Signal Type Signal Level 1 DCD I O DCD 2 DSR I O 3 RX I O 5V ...

Page 37: ...I O 7 DTR I O 8 RI PWR 5V 12V 9 GND GND 2 3 11 SATA2 0 Connector CN11 Pin Pin Name Signal Type Signal Level 1 GND GND 2 SATA_TXP1_C DIFF 3 SATA_TXN1_C DIFF 4 GND GND 5 SATA_RXN1_C DIFF 6 SATA_RXP1_C DIFF 7 GND GND 2 3 12 5V SATA Power Connector CN12 Pin Pin Name Signal Type Signal Level 1 5V PWR 5V ...

Page 38: ... 2 GND GND 2 3 13 PSON Output CN13 Pin Pin Name Signal Type Signal Level 1 PS_ON 2 GND GND 2 3 14 PCIe Connector CN14 Standard specification 2 3 15 3 3V and 5V Output CN15 Pin Pin Name Signal Type Signal Level 1 5V PWR 2 GND GND 3 3 3V PWR 2 3 16 SATA2 0 Connector CN16 ...

Page 39: ... 4 GND 5 SATA_RXN DIFF 6 SATA_RXP DIFF 7 GND 2 3 17 MiniCard Slot Full MiniCard CN17 Pin Pin Name Signal Type Signal Level 1 PCIE_WAKE IN 2 3 3VSB PWR 3 3V 3 NC 4 GND GND 5 NC 6 1 5V PWR 1 5V 7 PCIE_CLK_REQ IN 8 UIM_PWR PWR 9 GND GND 10 UIM_DATA I O 11 PCIE_REF_CLK DIFF 12 UIM_CLK IN 13 PCIE_REF_CLK DIFF 14 UIM_RST IN 15 GND GND 16 UIM_VPP PWR ...

Page 40: ...22 PCIE_RST OUT 3 3V 23 PCIE_RX DIFF 24 3 3VSB PWR 3 3V 25 PCIE_RX DIFF 26 GND GND 27 GND GND 28 1 5V PWR 1 5V 29 GND GND 30 SMB_CLK I O 3 3V 31 PCIE_TX DIFF 32 SMB_DATA I O 3 3V 33 PCIE_TX DIFF 34 GND GND 35 GND GND 36 USB_D DIFF 37 GND GND 38 USB_D DIFF 39 3 3VSB PWR 3 3V 40 GND GND 41 3 3VSB PWR 3 3V 42 NC 43 GND GND 44 NC ...

Page 41: ...1 NC 52 3 3VSB PWR 3 3V 2 3 18 MiniCard Slot Half MiniCard CN18 Pin Pin Name Signal Type Signal Level 1 PCIE_WAKE IN 2 3 3VSB PWR 3 3V 3 NC 4 GND GND 5 NC 6 1 5V PWR 1 5V 7 PCIE_CLK_REQ IN 8 UIM_PWR PWR 9 GND GND 10 UIM_DATA I O 11 PCIE_REF_CLK DIFF 12 UIM_CLK IN 13 PCIE_REF_CLK DIFF 14 UIM_RST IN 15 GND GND 16 UIM_VPP PWR ...

Page 42: ...22 PCIE_RST OUT 3 3V 23 PCIE_RX DIFF 24 3 3VSB PWR 3 3V 25 PCIE_RX DIFF 26 GND GND 27 GND GND 28 1 5V PWR 1 5V 29 GND GND 30 SMB_CLK I O 3 3V 31 PCIE_TX DIFF 32 SMB_DATA I O 3 3V 33 PCIE_TX DIFF 34 GND GND 35 GND GND 36 USB_D DIFF 37 GND GND 38 USB_D DIFF 39 3 3VSB PWR 3 3V 40 GND GND 41 3 3VSB PWR 3 3V 42 NC 43 GND GND 44 NC ...

Page 43: ... 1 5V PWR 1 5V 49 NC 50 GND GND 51 NC 52 3 3VSB PWR 3 3V 2 3 19 PS 2 Keyboard Mouse Combo Port CN19 Pin Pin Name Signal Type Signal Level 1 KB_DATA 2 KB_CLK 3 GND GND 4 V5A_KBMS PWR 5V 5 MS_DATA 6 MS_CLK 2 3 20 PCH Digital IO Port CN20 Pin Pin Name Signal Type Signal Level 1 PCH_GPIO0 2 GND ...

Page 44: ...5 PCH_GPIO2 6 GND 7 PCH_GPIO3 8 GND 2 3 21 UIM Card Socket CN21 Pin Pin Name Signal Type Signal Level 1 UIM_PWR1 I O 2 UIM_RST1 I O 3 UIM_CLK1 I O 4 GND GND 5 UIM_VPP1 I O 6 UIM_DAT1 I O 2 3 22 Digital IO Port CN22 Pin Pin Name Signal Type Signal Level 1 DIO_0 I O 2 DIO_1 I O 3 DIO_2 I O ...

Page 45: ...O 5 DIO_4 I O 6 DIO_5 I O 7 DIO_6 I O 8 DIO_7 I O 9 VCC_5V0 PWR 5V 10 GND GND 2 3 23 LPC Port CN26 Pin Pin Name Signal Type Signal Level 1 LPC_AD0 2 LPC_AD1 3 LPC_AD2 4 LPC_AD3 5 VCC_3V3 PWR 6 LPC_FRAME 7 BUF_PLT_RST 8 GND GND 9 CLK_PCI_FIN 10 PCH_DRQ 0 11 PCH_DRQ 1 12 INT_SERIRQ ...

Page 46: ...Port 8 and 9 Wafer BOX Optional CN29 Pin Pin Name Signal Type Signal Level 1 V5A_USB_8_9 PWR 5V 2 GND GND 3 USBD8 DIFF 4 GND GND 5 USBD8 DIFF 6 USBD9 DIFF 7 GND GND 8 USBD9 DIFF 9 GND GND 10 V5A_USB_8_9 PWR 5V 2 3 25 USB3 0 Wafer BOX Optional CN30 Pin Pin Name Signal Type Signal Level ...

Page 47: ... I O 3 USB3_RX0_BH_P I O 4 GND 5 USB3_TX0_BH_N 6 USB3_TX0_BH_P 7 GND 8 USBD2 9 USBD2 10 NC 11 USBD3 12 USBD3 13 GND 14 USB3_TX1_BH_P 15 USB3_TX1_BH_N 16 GND 17 USB3_RX1_BH_P 18 USB3_RX1_BH_N 19 V5A_USB_2_3 PWR 5V 2 3 26 External Power Input CN31 Pin Pin Name Signal Type Signal Level 1 VIN_EXT PWR 2 GND GND ...

Page 48: ...CN32 Pin Pin Name Signal Type Signal Level 1 LAN1_MDI0P I O 2 LAN1_MDI0N I O 3 LAN1_MDI1P I O 4 LAN1_MDI1N I O 5 LAN1_MDI2P I O 6 LAN1_MDI2N I O 7 LAN1_MDI3P I O 8 LAN1_MDI3N I O Pin Pin Name Signal Type Signal Level U1 V5A_USB_0_1 PWR 5V U2 USBD0 DIFF U3 USBD0 DIFF U4 GND GND U5 USB3_RX0_CON_N DIFF U6 USB3_RX0_CON_P DIFF ...

Page 49: ...0_1 PWR 5V U11 USBD1 DIFF U12 USBD1 DIFF U13 GND GND U14 USB3_RX1_CON_N DIFF U15 USB3_RX1_CON_P DIFF U16 GND GND U17 USB3_TX1_CON_N DIFF U18 USB3_TX1_CON_P DIFF 2 3 28 HDMI Port CN33 Pin Pin Name Signal Type Signal Level 1 HDMI_DATA2_P DIFF 2 GND GND 3 HDMI_DATA2_N DIFF 4 HDMI_DATA1_P DIFF 5 GND GND 6 HDMI_DATA1_N DIFF 7 HDMI_DATA0_P DIFF ...

Page 50: ...10 HDMI_CLK_P DIFF 11 GND GND 12 HDMI_CLK_N DIFF 13 NC 14 NC 15 HDMI_SCL 16 HDMI_SDA 17 GND GND 18 5V_HDMI PWR 5V 19 HDMI_HPD 2 3 29 LAN RJ 45 Dual USB2 0 CN34 Pin Pin Name Signal Type Signal Level 1 LAN2_MDI0P 2 LAN2_MDI0N 3 LAN2_MDI1P 4 LAN2_MDI1N 5 LAN2_MDI2P 6 LAN2_MDI2N 7 LAN2_MDI3P 8 LAN2_MDI3N ...

Page 51: ...nal Type Signal Level U1 V5A_USB_4_5 PWR 5V U2 USBD4 DIFF U3 USBD4 DIFF U4 GND GND U5 V5A_USB_4_5 PWR 5V U6 USBD5 DIFF U7 USBD5 DIFF U8 GND GND 2 3 30 COM Port 1 and 2 D SUB 9 CN35 Pin Pin Name Signal Type Signal Level 1 DCD1 I O 2 RX1 I O 5V 3 TX1 I O 5V 4 DTR1 I O 5 GND GND 6 DSR1 I O ...

Page 52: ...I1 PWR 5V 12V 10 DCD2 I O 11 RX2 I O 5V 12 TX2 I O 5V 13 DTR2 I O 14 GND GND 15 DSR2 I O 16 RT2 I O 17 CTS2 I O 18 RI2 PWR 5V 12V 2 3 31 COM Port 3 and 4 D SUB 9 CN36 Pin Pin Name Signal Type Signal Level 1 DCD3 I O 2 RX3 I O 5V 3 TX3 I O 5V 4 DTR3 I O 5 GND GND 6 DSR3 I O 7 RT3 I O 8 CTS3 I O ...

Page 53: ...XER 6852 9 RI3 PWR 5V 12V 10 DCD4 I O 11 RX4 I O 5V 12 TX4 I O 5V 13 DTR4 I O 14 GND GND 15 DSR4 I O 16 RT4 I O 17 CTS4 I O 18 RI4 PWR 5V 12V 2 3 32 Adapter Power in Connector CN37 Pin Pin Name Signal Type Signal Level 1 VIN_EXT PWR 2 GND_PRI GND 3 GND_EARTH GND ...

Page 54: ...D Port CN38 Pin Pin Name Signal Type Signal Level 1 DVI_DATA2_N DIFF 2 DVI_DATA2_P DIFF 3 GND GND 4 NC 5 NC 6 DVI_DDC_SCL 7 DVI_DDC_SDA 8 NC 9 DVI_DATA1_N DIFF 10 DVI_DATA1_P DIFF 11 GND 12 NC 13 NC 14 V5S_DVI_CON PWR 5V 15 GND 16 DVI_HPD 17 DVI_DATA0_N DIFF 18 DVI_DATA0_P DIFF 19 GND ...

Page 55: ...Embedded Box PC BOXER 6852 20 NC 21 NC 22 GND 23 DVI_CLK_P DIFF 24 DVI_CLK_N DIFF 25 GND 26 GND 27 GND 28 GND 29 DDC_CLK 30 NC 31 V5S_DISP PWR 5V 32 HSYNC 33 GREEN 34 GND 35 NC 36 GND 37 CRT_PLUG 38 VSYNC 39 BLUE 40 GND 41 DDC_DAT 42 RED 43 GND ...

Page 56: ... Box PC BOXER 6852 2 3 34 LAN2 LED LED 1 Pin Pin Name Signal Type Signal Level 1 3 3V 2 LAN2_LINK_ACT 3 LAN2_1000 4 LAN2_100 2 3 35 LAN1 LED LED 2 Pin Pin Name Signal Type Signal Level 1 3 3V 2 LAN1_LINK_ACT 3 LAN1_1000 4 LAN1_100 2 3 36 LAN1 LED LED 2 ...

Page 57: ...Chapter 2 Hardware Information 43 Fanless Embedded Box PC BOXER 6852 Pin Pin Name Signal Type Signal Level 1 5V 2 HDD_LED 3 5V 4 PWR_LED ...

Page 58: ...anless Embedded Box PC BOXER 6852 2 4 Installing Components To installing components such as hard disks and RAMs you will have to access the system s interior Please follow the instruction below to do so Remove the brackets and the base ...

Page 59: ...Chapter 2 Hardware Information 45 Fanless Embedded Box PC BOXER 6852 2 4 1 Installing MiniCard 1 Slot the MiniCard into the slot diagonally 2 Secure the card with screws ...

Page 60: ...Chapter 2 Hardware Information 46 Fanless Embedded Box PC BOXER 6852 2 4 2 Installing CFast SIM Card Remove the cover to insert the cards ...

Page 61: ...Chapter 2 Hardware Information 47 Fanless Embedded Box PC BOXER 6852 2 4 3 Installing HDD 1 Place the HDD onto the bracket plate and secure with screws ...

Page 62: ...Chapter 2 Hardware Information 48 Fanless Embedded Box PC BOXER 6852 2 Place the assembly onto the baseplate and secure with screws ...

Page 63: ...Chapter 2 Hardware Information 49 Fanless Embedded Box PC BOXER 6852 2 4 4 Installing RAM 1 Slot the RAM diagonally into the RAM slot and push down to secure ...

Page 64: ...Chapter 2 Hardware Information 50 Fanless Embedded Box PC BOXER 6852 2 Place the thermal pad onto the RAM 3 Place the cover onto the RAM tighten the screws to secure the cover ...

Page 65: ...Hardware Information 51 Fanless Embedded Box PC BOXER 6852 2 4 5 Wallmounting To mount the device onto a vertical surface please refer to the diagram below for the screws required and attach them to the brackets ...

Page 66: ...Fanless Embedded Box PC BOXER 6852 Chapter 3 Chapter 3 AMI BIOS Setup ...

Page 67: ...es check the current system configuration against the values stored in the CMOS memory If they do not match an error message will be outputted in which case you will need to run the BIOS setup program to set the configuration information in memory There are three situations in which you will need to change the CMOS settings You are starting your system for the first time You have changed your syst...

Page 68: ...d when the power is turned off To enter BIOS Setup press Del or F2 immediately while your computer is powering up The function for each interface can be found below Main Date and time can be set here Press Tab to switch between date elements Advanced Enable Disable boot option for legacy network devices Chipset For hosting bridge parameters Boot Enable Disable quiet Boot Option Security The setup ...

Page 69: ...Chapter 3 AMI BIOS Setup 55 Fanless Embedded Box PC BOXER 6852 3 3 Setup Submenu Main ...

Page 70: ...Chapter 3 AMI BIOS Setup 56 Fanless Embedded Box PC BOXER 6852 3 4 Setup Submenu Advanced ...

Page 71: ...Chapter 3 AMI BIOS Setup 57 Fanless Embedded Box PC BOXER 6852 3 4 1 F81866 Super IO Configuration ...

Page 72: ...ration Options summary Serial Port Disabled Enabled Optimal Default Failsafe Default Enable or Disable Serial Port COM Change Settings Auto Optimal Default Failsafe Default IO 3E8h IRQ 4 IO 3F8h IRQ 3 4 5 6 7 10 11 12 IO 2E8h IRQ 3 4 5 6 7 10 11 12 IO 3E8h IRQ 10 IO 2E8h IRQ 10 Select an optimal setting for Super IO device ...

Page 73: ...Port 2 Configuration Options summary Serial Port Disabled Enabled Optimal Default Failsafe Default Enable or Disable Serial Port COM Change Settings Auto Optimal Default Failsafe Default IO 2E8h IRQ 3 IO 3F8h IRQ 3 4 IO 2F8h IRQ 3 4 IO 3E8h IRQ 3 4 IO 2E8h IRQ 3 4 Select an optimal setting for Super IO device ...

Page 74: ...abled Optimal Default Failsafe Default Enable or Disable Serial Port COM Change Settings Auto Optimal Default Failsafe Default IO 3E8h IRQ 10 IO 3E8h IRQ 10 IO 2E8h IRQ 10 IO 2D0h IRQ 10 IO 2C0h IRQ 10 Select an optimal setting for Super IO device Serial Port Mode RS232 422 Optimal Default Failsafe Default RS485 Serial Port Mode selection For switch RS232 422 485 mode ...

Page 75: ...abled Optimal Default Failsafe Default Enable or Disable Serial Port COM Change Settings Auto Optimal Default Failsafe Default IO 2E8h IRQ 10 IO 3E8h IRQ 10 IO 2E8h IRQ 10 IO 2D0h IRQ 10 IO 2C0h IRQ 10 Select an optimal setting for Super IO device Serial Port Mode RS232 422 Optimal Default Failsafe Default RS485 Serial Port Mode selection For switch RS232 422 485 mode ...

Page 76: ... Port 5 Configuration Options summary Serial Port Disabled Enabled Optimal Default Failsafe Default Enable or Disable Serial Port COM Change Settings Auto Optimal Default Failsafe Default IO 2F0h IRQ 10 IO 3E8h IRQ 10 IO 2E8h IRQ 10 IO 2D0h IRQ 10 IO 2C0h IRQ 10 Select an optimal setting for Super IO device ...

Page 77: ... Disable Serial Port COM Change Settings Auto Optimal Default Failsafe Default IO 2E0h IRQ 10 IO 3E8h IRQ 10 IO 2E8h IRQ 10 IO 2D0h IRQ 10 IO 2C0h IRQ 10 Select an optimal setting for Super IO device Device Mode Disable IR1 function Optimal Default Failsafe Default Enable IR1 function active pulse 1 6uS Enable IR1 function active pulse 3 16 bit time Change the Serial Port mode Select High Speed or...

Page 78: ...Chapter 3 AMI BIOS Setup 64 Fanless Embedded Box PC BOXER 6852 3 4 2 Advanced F81866 H W Monitor ...

Page 79: ...I sleep state the system will enter when the SUSPEND button is pressed Restore on Power Loss Power Off Power On Last State Optimal Default Failsafe Default Select power state when power is re applied after a power failure Wake on LAN Enabled Optimal Default Failsafe Default Disabled Enable or disable integrated LAN to wake the system The wake On LAN cannot be disabled if ME is on at Sx state Resum...

Page 80: ...Disabled Enabled Optimal Default Failsafe Default Enable Disable Resume from RI signal RTC wake system from S5 Disabled Optimal Default Failsafe Default Fixed Time Dynamic Time Enable or disable System wake on alarm event When enabled System will wake on the hr min sec specified ...

Page 81: ...Chapter 3 AMI BIOS Setup 67 Fanless Embedded Box PC BOXER 6852 3 4 4 Advanced CPU Configuration ...

Page 82: ...reading Technology and Disabled for other OS OS not optimized for Hyper Threading Technology When Disabled only one thread per enabled core is enabled Intel Virtualization Technology Disabled Enabled Optimal Default Failsafe Default When enabled a VMM can utilize the additional hardware capabilities provided by Vanderpool Technology Turbo Mode Disable Enable Optimal Default Failsafe Default Turbo ...

Page 83: ...ault Failsafe Default Enable Disable Intel R Active Management Technology BIOS Extension Note iAMT H W is always enabled This option just controls the BIOS extension execution If enabled this requires additional firmware in the SPI device Un Configure ME Disabled Optimal Default Failsafe Default Enabled OEMFlag Bit 15 Un Configure ME without password ...

Page 84: ...4 6 Advanced Trusted Computing Options summary Security Device Support Disabled Optimal Default Failsafe Default Enabled Enables or Disables BIOS support for security device O S will not show Security Device TCG EFI protocol and INT1A interface will not be available ...

Page 85: ...R 6852 3 4 7 Advanced SATA Configuration Options summary SATA controller s Enabled Optimal Default Failsafe Default Disabled Enable or disable SATA Device SATA Mode Selection IDE Optimal Default Failsafe Default AHCI Determines how SATA controller s operate ...

Page 86: ...nabled Optimal Default Failsafe Default Disabled Auto Enables Legacy USB support AUTO option disables legacy support if no USB devices are connected DISABLE option will keep USB devices available only for EFI applications USB3 0 Support Smart Auto Optimal Default Failsafe Default Enabled Disabled Mode of operation of xHCI controller ...

Page 87: ...ons summary DIO 3 0 Direction Input Optimal Default Failsafe Default Output Set Digital IO as Input or Output DIO 7 4 Direction Input Output Optimal Default Failsafe Default Set Digital IO as Input or Output DIO 3 0 Output Level Hi Optimal Default Failsafe Default Low Set Digital IO Output as Hi or Low ...

Page 88: ...Chapter 3 AMI BIOS Setup 74 Fanless Embedded Box PC BOXER 6852 3 5 Setup submenu Chipset ...

Page 89: ... Express X1 CN14 port speed PCIe X1 CN25 Auto Optimal Default Failsafe Default Gen1 Gen2 Select PCI Express X1 CN25 port speed Mini Card CN18 Auto Optimal Default Failsafe Default Gen1 Gen2 Select Mini Card CN18 port speed Mini Card CN17 Auto Optimal Default Failsafe Default Gen1 Gen2 Select Mini Card CN17 port speed PCH LAN Controller Enabled Optimal Default Failsafe Default Disabled ...

Page 90: ...disable onboard NIC Azalia Disabled Enabled Auto Optimal Default Failsafe Default Control Detection of the Azalia device Disabled Azalia will be unconditionally disabled Enabled Azalia will be unconditionally Enabled Auto Azalia will be enabled if present disabled otherwise ...

Page 91: ...E Select which of IGFX PEG PCI Graphics device should be Primary Display Internal Graphics Auto Optimal Default Failsafe Default Disabled Enabled Keep IGD enabled based on the setup options Primary IGFX Boot Display VBIOS Default Optimal Default Failsafe Default CRT HDMI DVI Secondary IGFX Boot Display Disabled Optimal Default Failsafe Default CRT HDMI DVI Select Secondary Display Device ...

Page 92: ...Chapter 3 AMI BIOS Setup 78 Fanless Embedded Box PC BOXER 6852 3 5 2 1 System Agent SA Configuration Memory Configuration ...

Page 93: ...Boot Options summary Quiet Boot Disabled Enabled Default En Disable showing boot logo Launch I217 LM PXE OpROM Disabled Default Enabled Enable or Disable Legacy Boot Option for I217 LM Launch I211 AT PXE OpROM Disabled Default Enabled Enable or Disable Legacy Boot Option for I211 AT ...

Page 94: ...Chapter 3 AMI BIOS Setup 80 Fanless Embedded Box PC BOXER 6852 3 6 1 Boot BBS Priorities ...

Page 95: ... not provide access to many of the features in the Setup utility Select the password you wish to set press Enter to open a dialog box to enter your password you can enter no more than six letters or numbers Press Enter to confirm your entry after which you will be prompted to retype your password for a final confirmation Press Enter again after you have retyped it correctly Removing the Password H...

Page 96: ...Chapter 3 AMI BIOS Setup 82 Fanless Embedded Box PC BOXER 6852 3 8 Setup submenu Save Exit ...

Page 97: ...Fanless Embedded Box PC BOXER 6852 Chapter 4 Chapter 4 Drivers Installation ...

Page 98: ...F folder followed by SetupChipset exe 2 Follow the instructions 3 Drivers will be installed automatically Step 2 Install Graphics Driver 1 Open the Step2 Graphic folder and select your OS 2 Open the exe file in the folder 3 Follow the instructions 4 Drivers will be installed automatically Step 3 Install USB3 0 Driver Windows 7 only 1 Open the Step3 USB3 0 folder followed by Setup exe 2 Follow the ...

Page 99: ... 4 Drivers will be installed automatically Step 6 Install RAID_AHCI Driver 1 Open the Step6 RAID_AHCI folder 2 Open NDP452 KB2901907 x86 x64 AllOS ENU exe 3 Open the SetupRST exe in the folder 4 Follow the instructions 5 Drivers will be installed automatically Step 7 Install ME Driver 1 Open the Step7 ME folder followed by setup exe 2 Follow the instructions 3 Drivers will be installed automatical...

Page 100: ...ter 4 Driver Installation 86 Fanless Embedded Box PC BOXER 6852 Step 8 Install UART Drivers Optional For Windows 7 1 Change User Account Control settings to Never notify 2 Reboot and log in as administrator ...

Page 101: ...Chapter 4 Driver Installation 87 Fanless Embedded Box PC BOXER 6852 3 Run patch bat as administrator ...

Page 102: ...or 2 To install the driver patch bat you will first have to locate the file in command prompt To do that go to the folder in which the file resides by entering cd file path eg if the file is in a folder named abc in c drive enter cd c abc screenshot for reference only 3 You are now at the folder where the file is located Enter the patch bat to open and install the drivers ...

Page 103: ...llation completes 5 To confirm the installation go to Device Manager expand the Ports COM LPT tree and double click on any of the COM ports to open its properties Go to the Driver tab select Driver Details and click on serial sys you should see its provider as Windows R Win 7 DDK Provider ...

Page 104: ...Chapter 4 Driver Installation 90 Fanless Embedded Box PC BOXER 6852 ...

Page 105: ...Fanless Embedded Box PC BOXER 6852 Appendix A Appendix A Watchdog Timer Programming ...

Page 106: ...e Note Timer Counter 0x07 Note3 0xF6 Note4 Note24 Time of watchdog timer 0 255 This register is byte access Counting Unit 0x07 Note5 0xF5 Note6 3 Note7 0 Note8 Select time unit 0 second 1 minute Watchdog Enable 0x07 Note9 0xF5 Note10 5 Note11 1 Note12 0 Disable 1 Enable Timeout Status 0x07 Note13 0xF5 Note14 6 Note15 1 1 Clear timeout status Output Mode 0x07 Note16 0xF5 Note17 4 Note18 1 Note19 Se...

Page 107: ...is parameter is represented from Note8 define byte EnableLDN This parameter is represented from Note9 define byte EnableReg This parameter is represented from Note10 define byte EnableBit This parameter is represented from Note11 define byte EnableVal This parameter is represented from Note12 define byte StatusLDN This parameter is represented from Note13 define byte StatusReg This parameter is re...

Page 108: ...s Embedded Box PC BOXER 6852 VOID Main Procedure AaeonWDTConfig byte Timer Time of WDT timer 0x00 0xFF boolean Unit Select time unit 0 second 1 minute AaeonWDTConfig Procedure AaeonWDTEnable This procudure will enable the WDT counting AaeonWDTEnable ...

Page 109: ...elative parameter setting WDTParameterSetting VOID WDTEnableDisable byte LDN byte Register byte BitNum byte Value SIOBitSet LDN Register BitNum Value VOID WDTParameterSetting Watchdog Timer counter setting SIOByteSet TimerLDN TimerReg TimerVal WDT counting unit setting SIOBitSet UnitLDN UnitReg UnitBit UnitVal WDT output mode setting level pulse SIOBitSet ModeLDN ModeReg ModeBit ModeVal Watchdog t...

Page 110: ...Register Offset 0x07 IOWriteByte SIOData LDN VOID SIOBitSet byte LDN byte Register byte BitNum byte Value Byte TmpValue SIOEnterMBPnPMode SIOSelectLDN byte LDN IOWriteByte SIOIndex Register TmpValue IOReadByte SIOData TmpValue 1 BitNum TmpValue Value BitNum IOWriteByte SIOData TmpValue SIOExitMBPnPMode VOID SIOByteSet byte LDN byte Register byte Value SIOEnterMBPnPMode SIOSelectLDN LDN IOWriteByte...

Page 111: ...Fanless Embedded Box PC BOXER 6852 Appendix B Appendix B I O Information ...

Page 112: ...Appendix B I O Information 98 Fanless Embedded Box PC BOXER 6852 B 1 I O Address Map ...

Page 113: ...Appendix B I O Information 99 Fanless Embedded Box PC BOXER 6852 ...

Page 114: ...Appendix B I O Information 100 Fanless Embedded Box PC BOXER 6852 B 2 Memory Address Map ...

Page 115: ...Appendix B I O Information 101 Fanless Embedded Box PC BOXER 6852 B 3 IRQ Mapping Chart ...

Page 116: ...Appendix B I O Information 102 Fanless Embedded Box PC BOXER 6852 ...

Page 117: ...Appendix B I O Information 103 Fanless Embedded Box PC BOXER 6852 ...

Page 118: ...Appendix B I O Information 104 Fanless Embedded Box PC BOXER 6852 ...

Page 119: ...Appendix B I O Information 105 Fanless Embedded Box PC BOXER 6852 ...

Page 120: ...Appendix B I O Information 106 Fanless Embedded Box PC BOXER 6852 ...

Page 121: ...Appendix B I O Information 107 Fanless Embedded Box PC BOXER 6852 ...

Page 122: ...Appendix B I O Information 108 Fanless Embedded Box PC BOXER 6852 ...

Page 123: ...Appendix B I O Information 109 Fanless Embedded Box PC BOXER 6852 ...

Page 124: ...Appendix B I O Information 110 Fanless Embedded Box PC BOXER 6852 ...

Page 125: ...Appendix B I O Information 111 Fanless Embedded Box PC BOXER 6852 B 4 DMA Channel Assignments ...

Reviews: