![Astronergy 5KTL-M2 Installation & Operation Manual Download Page 22](http://html1.mh-extra.com/html/astronergy/5ktl-m2/5ktl-m2_installation-and-operation-manual_2991311022.webp)
20
CYCLE DISPLAY
DISPLAY TIME/S
REMARK
2
Setting Zigbee Channel
4
record of the 5 latest grid faults
4
Setting year/month/day/time
6.3
Setting the LCD display
Sound control can define the display language, luminance of the display, auto test etc. when the LCD is dark, any knock to
make it bright, and then single knock to make it display next item or change the setting options. Double knock can either
make the displays stayed for 30s or enter the options which need to be modified.
Setting language
When the LCD stays bright, single knock to ‘set language’, and then double knock to enter the language options. Single knock
to select the language you want, when setting finishes, wait for 30s or triple knock to save your setting.
Setting COM Address
When the LCD stays bright, single knock to ‘COM Address: xxx’, and then double knock to enter the setting status, single knock
to change the COM Address. When setting finishes, wait for 30s or triple knock to save your setting.
Auto test
When the LCD stays bright, single knock to ‘Enable Auto Test’, and then double knock to enter ‘Waiting to start’, and then single
knock to start auto test and wait for the test results.
Communication Type
•
RS 232
•
Inter wireless
•
Exter wireless
(NOTE: RS485 is the standard communication type of the inverter)