Power A green LED
and
Power B red LED:
Power supply A in operation
Power plug B not connected
or power supply B defective
Power A red LED
and
Power B green LED:
Power supply B in operation
Power plug A not connected
or power supply A is defective.
All LEDs off:
Power plug not connected or
power units defective.
Note:
If only one power LED is lit with an installed VSN 2
redundant power supply, or if both power LEDs are lit
with an installed VSN 1 single power supply, the device
settings have to be corrected as described under 3.3.
11
7 Indicators (front LEDs)
8 Level adjustment
8
Level adjustment
The optimal output level (measured at the output of the
base device) is as follows:
•
100 dBµV for PAL channels
•
90 dBµV for QAM channels
•
96 dBµV for radio (FM) channels
To enable the setting, the level regulators of the indivi-
dual plug-in cards are set accordingly (Fig. 14).
The level adjustment can be done via HE programming
software depending on the plugin-card.
Note:
Under no circumstances should a skewed position be
set to compensate outgoing cable attenuation by means
of different level adjustments of the plug-in cards! For
this purpose use output coupling field
U-901
(order no.
380 190) or
VZN 8
(order no. 380 191).
Slot 1
Slot 2
Slot 3
Slot 4
Slot 5
Slot 6
Slot 7
Slot 8
Power A
Power B
Slot 1
Slot 2
Slot 3
Slot 4
Slot 5
Slot 6
Slot 7
Slot 8
Power A
Power B
Fig.14
Level regulators