WARNING
: Failure to replace the access plate will
result in an electrical hazard and possible heat damage
to electrical components.
8.4 Tank Controller Replacement
1. Disconnect melt unit electrical power.
2. Open front control panel.
3. Remove tank access panel at bottom of electrical panel.
4. Remove wires connected to thermostat. Tank thermostat
controller is the elongated thermostat mounted horizontally on
the tank base plate.
5. Remove screws holding tank thermostat to tank.
6. Apply even coating of heat sink compound to base of the new
thermostat.
7. Attach replacement thermostat to the tank assembly using the
mounting clip and screws. Reconnect wires.
8. Replace tank access plate.
9. Close front control panel.
!
© Copyright 2010 Astro Packaging
LS10 and LS20 19600-121
27
(800-401-1441