Astria MONTECITO ESTATE Installation And Operation Instructions Manual Download Page 7

  WARNING

 

Use only a IHP glass doors, specifically designed 

for the Montecito Estate™ fireplace.

 

The fireplace cannot be operated without door or 

firescreen.  Consult your dealer to select the correct 

replacement door or firescreen.

 

Important! To assure proper alignment of glass 

doors:    Install  this  fireplace  in  a  square  and 

plumb condition, using shims as necessary at 

sides and/or bottom.

2

Figure 7

DO NOT USE CHEMICAL GLASS CLEANERS ON PAINTED SURFACES AS 

IT MAY CAUSE THE PAINT TO PEEL.

CAUTION : DO NOT ALLOW WINDOW CLEANER TO GET IN CONTACT 

WITH DOOR GASKET OR PAINT ON FACADE OR DOOR.  ONCE CLOSED, 

CONTACT OF GLASS CLEANER WITH THE FIREPLACE FACADE CAN 
PROVOKE PAINT PEELING OFF.

Gasket Replacement

Remove the doors from the unit (see section 

Door Installation)

 and lay 

them on a clean nonabrasive surface. To replace the gasket, first remove 

all of the old gasket and gasket cement.  Make sure that the surface is 

totally clean before applying new cement (a high temperature silicone 

caulking rated at 500° F (260° C), is suitable) or adhesion problems may 

result.  Apply gasket cement to the gasket channel and install the new 

gasket.  This replacement part is available from your IHP dealer in the 

following dimensions:

Gasket

Part #

Length

qty

Dimensions

Around the 

glass

PR-SR1685C

61-3/4”

(1569 mm)

2

1” width x 3/16” thick

(26 mm x 5 mm)

On the door 

frame

PR-SR1823I

48-3/8”

(1229 mm)

2

3/4” diameter

(19 mm)

Between the 

doors

PR-SR1823J

17-5/8”

(448 mm)

2

5/8” diameter

(16 mm)

Table 1

1

GLASS CARE

Glass Replacement

The glass used for the Montecito Estate fireplace is a high temperature 

ceramic glass (1,400° F).  If the glass breaks or cracks, it must be 

replaced with an identical ceramic glass.  Tempered glass or ordinary 

glass will not withstand the high temperatures of the Montecito Estate 

fireplace .  Replacement glass should be purchased from a IHP dealer 

(see 

“Replacement Parts”

 on 

Page 23

)

DO NOT OPERATE THE UNIT WITH CRACKED OR BROKEN GLASS.

Glass Cleaning

The Montecito Estate fireplace is designed to keep the glass clean under 

normal operating conditions. If the Montecito Estate fireplace is operated 

continuously with the combustion air controls closed, the glass will tend to 

get dirty unless the fuel, firebox and glass are maintained at hot tempera-

tures (see section 

Refueling For Best Performance)

.  To clean the glass, 

there are a number of specially designed cleaners to remove creosote.  

Your IHP Dealer can recommend a suitable cleaner.  Regular household 

glass cleaners will not clean creosote. 

 Do not use abrasives such as 

steel pads, steel wool or oven cleaner as they will scratch the glass.

FIREPLACE INSTALLATION

Locating The Montecito Estate Fireplace

The best location to install your fireplace is determined by considering 

the location of windows, doors, and the traffic flow in the room where 

the fireplace is located, allowing space in front of the unit for the hearth 

extension and the mantel, and taking into consideration the location of 

the hot air ducts (optional), outside air kit and chimney.  If possible, 

you should choose a location where the chimney will pass through the 

house without cutting floor or roof joists (see fireplace dimensions on 

Pages 9 and 10

).

Usually, no additional floor support is needed for the fireplace.  The ad

-

equacy of the floor can be checked by first estimating the weight of the 

fireplace system.  Weights are given in the appendix.  Next, measure the 

area occupied by the fireplace.  Note the floor construction and consult 

your local building code to determine if additional support is needed. 

The Montecito Estate fireplace may be installed directly on the floor or 

on a raised base and a minimum of 80” measured from the base of the 

appliance to the ceiling is required.

7

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Summary of Contents for MONTECITO ESTATE

Page 1: ...27 Report No 304 7213 EPA Cert No 609 WARNING Hot Do not touch The glass and surfaces of this appliance will be hot during operation and will retain heat for a while after shutting off the appli ance...

Page 2: ...NING Neverleavechildrenunattended when there is a fire burning in the fireplace IMPORTANT GENERAL SAFETY PRECAUTIONS READ AND UNDERSTAND THESE SAFETY RULES BEFORE YOUR FIRST FIRE WARNING Never leave y...

Page 3: ...l void the certification and the warranty of the fireplace and may result in an unsafe installation These appliances are designed to provide supplementalheattotheimmediateareaonly Therefore it is advi...

Page 4: ...be well ventilated for the first few fires Heat Output The Montecito Estate fireplace is the largest memberoftheIHPhighefficiencyfireplaces The heat generated from its fire is more efficiently captur...

Page 5: ...ally go to that level after the fire is fully established and the air boost is closed The unit will burn best with 2 3 pieces of cord wood spaced 1 to 2 inches apart and allowing air to get under the...

Page 6: ...ire follow these steps 1 IMPORTANT Close the fireplace door and the combustion air controls this will stifle the fire 2 Alert your family of the possible danger 3 If you require assistance alert your...

Page 7: ...eplace Replacement glass should be purchased from a IHP dealer see Replacement Parts on Page 23 DO NOT OPERATE THE UNIT WITH CRACKED OR BROKEN GLASS Glass Cleaning The Montecito Estate fireplace is de...

Page 8: ...irection of the wind are important factor affecting the chimney performance To allow a maximum draft and to reduce wind turbulence the chimney must Penetrate the highest part of the roof Be installed...

Page 9: ...dards and the following illustrations Figures 10 and 11 A Frame the fireplace using 2 x 3 or heavier lumber B WARNING Combustible materials can not be used in the space directly above the fireplace e...

Page 10: ...spacer minus 1 2 inch for drywall to be flush with the facing 7 Min B G 2 x 3 Min K Combustion Air Kit 1 Combustible material must be installed flush with the fireplace It may not project in front of...

Page 11: ...er 7 Brick Fireplace Frame Section Top View Figure 12 Only non combustible material should be superposed or project ing over the front of the fireplace Figure 14 50 Min SEE NOTE MANTEL and FACING The...

Page 12: ...d on the bottom right corner of the fireplace If you wish to adjust the blower speed the variable speed control VRUW provided must be installed in line with the wiring Again use a qualified electricia...

Page 13: ...es up to ten 10 feet long 4 Adaptor for fireplace connection Outside Air Installation The outside air assembly may be installed according to the following requirements A Duct length should be kept to...

Page 14: ...orrosion problems 9 Cut and frame square holes in all floors ceilings and roof that the chimney will go through to provide a 2 51mm clearance between thechimneyandanycombustiblematerials Atthepointofp...

Page 15: ...ing in place and seal the joint between the roof and the flashing with roofing pitch see Figures 24 and 25 For sloping roofs place the flashing under the upper shingles and on top of the lower shingle...

Page 16: ...must be used on the first 15 section 5 m 7 Continue with the regular installation ACBI Chimney 1 Install the first elbow Turn it in the required direction To lock it in place turn 1 8 of a turn Faste...

Page 17: ...4 1 8 1375 mm B 17 9 16 446 mm 20 7 16 519 mm 24 5 8 625 mm 28 7 8 733mm 37 3 8 949 mm 42 1067 mm 44 3 4 1137 mm 49 1245 mm 59 9 32 1353 mm 61 3 4 1568 mm Chimney Elbow Offset Height One Length Betwee...

Page 18: ...ey in a insulated chase Straps Chimney ACBI ACBI Starter Section Straps Outside Wall OFFSET CHIMNEY INSTALLATION WITH WALL PENETRATION Support NOTE This illustration is not to scale It represents how...

Page 19: ...ey height exceeds 15 feet 4 6 m Table 6 gives maximum height of supported chimney NOTE FortheACBIchimney asupportsection ACBI7SL mustbeused every 30 feet 9m or an universal support every 20 feet 6m in...

Page 20: ...chimney 2 In the middle of the oval drill a hole in the masonry chimney at 30 3 Increase the size of the hole until a 30 Tubinox liner elbow can be easily slipped through 4 Slide the liner down from t...

Page 21: ...ow 90 8 dia 7B26ZE90 H8948 Elbow 45 8 dia 7B26ZE45 H8949 Telescopic length 8 dia 15 to 26 7B26ZLA H8950 Adjustable length 8 dia 2 5 7B26ZL2A H8951 Length two 2 feet 8KL2 H8954 Length one 1 feet 8KL1 H...

Page 22: ...Caps Black 2 PR SACMEFBK Decorative Screw Caps Brushed Nickel 2 PR SACMEFBN Timer PR SR2425 Ceramic Glass Left PR SR2356G Ceramic Glass Right PR SR2356D Secondary Air Tube 4 PR SR2379 Log Retainers 2...

Page 23: ...SMI30 7XRSMI30 Wall Band XBM XBM Fireplace Model MONTEST Approved Venting Components manu factured by Security Chimneys International only 7 diameter chimney ACBI air cooled Secure Temp GX U S only an...

Page 24: ...M at 2100 F Description Cat Part No 6 Length 7 Dia 7LL6 7LL6 12 Length 7 Dia 7LL12 7LL12 24 Length 7 Dia 7LL24 7LL24 36 Length 7 Dia 7LL36 7LL36 48 Length 7 Dia 7LL48 7LL48 Adjustable Length 7 to 11 7...

Page 25: ...inder may burn at excessive temperatures and may cause damage to the Product or may cause it to function improperly IHP stoves inserts and high efficiency EPA fireplaces are approved for burning dry s...

Page 26: ...e Page 22 for a complete replacement parts list Use only parts sup plied from the manufacturer Normally all parts should be ordered through your IHP distributor or dealer Parts will be shipped at prev...

Reviews: