28
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Innovative Hearth Products
Montebello
®
ST Direct-Vent Gas Fireplaces
Installation Instructions
900355-00, 06/2016
CAUTION
Ground supply lead must be connect-
ed to the wire attached to the green
ground screw located on the outlet
box. See
Figures 35 and 36
. Failure to
do so will result in a potential safety
hazard. The appliance must be elec-
trically grounded in accordance with
local codes or, in the absence of local
codes, the National Electrical Code,
ANSI/NFPA 70-latest edition.
Step 4. FIELD WIRING
CAUTION: Label all wires prior to discon-
nection when servicing controls. Wiring
errors can cause improper and dangerous
operation.
ATTENTION: Au moment de l'entretien
des commandes, étiquetez tous les fils
avant de les débrancher. Des erreurs
de cáblage peu-vent entraîner un fonc-
tionnement inadéquat et dangereux.
Verify proper operation after servicing.
S'assurer que l'appareil fonctionne adé-
quatement une fois l'entretien terminé.
Figure 35 - Electronic Wiring Diagram for Gravity Vent Fireplaces
Figure 36 - Junction Box Wiring
Proflame
DFC Board
Pilot
Ground
Wire
Pilot
Tube
Electronic Pilot Assembly
Igniter Rod
Hood
Spark Wire Cable
Pilot Sensor Cable
Flame
Sensor
Proflame Valve
Electronic Modulation
Wall Receiver
Cable Harness 102661-01
AC/DC
Power Adaptor
Hi-Temp Sleeve
Unit Mounted Rocker Switch
OFF (o) = Intermittent Pilot Mode
ON (-) = Standing Pilot Mode
DFC Wire Harness 102662-01
Y
G
O
Y
G
O
W
W
W
G
THIS CONNECTOR NOT
USED ON GRAVITY
VENT UNITS
PU
BL
G
PU
BL
G
W
B
BR
Y
O
R GY
B
BR
Y
O
Wiring Color Code
B = Black
BL = Blue
BR = Brown
G = Green
GY = Gray
O= Orange
PU = Purple
W = White
R = Red
Y = Yellow
Neutral
Hot
Ground
Junction Box
120V AC
G
B
W
Y
R
B
ELECTRONIC WIRING DIAGRAM FOR GRAVITY VENT FIREPLACES
(See Figure 36 for detailed drawing
of junction box / receptacle wiring.)
Electronic Wiring
(See Figures 35 and 36)
Note: The electronic appliance must be
connected to the main power supply.
1. Route a 3-wire, 120 Vac, 60 Hz, 1ph power
supply to the appliance junction box.
2. Remove the electrical inlet cover plate from
the side of the unit by removing the plate's
securing screws (
see Figure 14, Page 17).
3. Remove the cover plate’s knockout and then
feed the power supply wire through the
knockout opening and into the unit junction
box.
4. Connect the black power supply wire to the
power outlet’s red pigtail lead and the white
power supply wire to the common terminal
of the outlet as shown in
Figures 35 and 36.
5. Connect the ground supply wire to the pig-
tail lead attached to outlet's green ground
screw.
6. Appliance-mounted ON/OFF burner control
switch (rocker switch) is factory installed.
7. After wiring is complete, replace the cover
plate.
Green
Ground
Screw
Black
Red
Hot
Side of
Receptacle
Tab Intact
Green
White
120 VAC - Black
Neutral - White
Ground - Green
J-BOX / RECEPTACLE
WIRING
120V, 60HZ, 1PH
Junction Box
Field Wired
Factory Wired
Neutral
Side of
Receptacle
Tab Intact