 WARNING: Do not allow fans 

to blow directly into the firebox. 

Avoid any drafts that alter burner 

flame patterns. Ceiling fans can 

create drafts that alter burner 

flame  patterns. Altered  burner 

patterns can cause sooting.

TABLE OF CONTENTS

Safety .................................................................. 2

Local Codes......................................................... 4

Product Features ................................................. 4

Locating Firebox .................................................. 4

Product Specifications

 ......................................... 5

Air For Combustion and Ventilation ..................... 8

Installation ......................................................... 10

Firebrick Wall Installation ................................... 14

Gas Line Installation .......................................... 15

Technical Service............................................... 17

Replacement Parts ............................................ 17

Parts .................................................................. 18

Warranty ............................................................ 23

SAFETY

This appliance may be installed 

in an aftermarket,* permanently 

located, manufactured (mobile) 

home, where not prohibited by 

local codes.

* Aftermarket: Completion of sale, not for 

purpose of resale, from the manufacturer

This  firebox  has  been  tested 

under  Z21.91b-2007  for  use 

with  approved ANSI  Z21.11.2 

decorative type unvented room 

heater.

IMPORTANT: Read this owner’s 

manual carefully and completely 

before trying to assemble, op-

erate  or  service  this  fireplace. 

Improper  use  of  this  fireplace 

can cause serious injury or 

death  from  burns,  fire,  explo-

sion, electrical shock and carbon 

monoxide poisoning.

 DANGER: Carbon monoxide 

poisoning may lead to death!

 

WARNING:  Improper  installation,  adjustment,  al-

teration,  service  or  maintenance  can  cause  injury  or 

property damage. Refer to this manual for correct in-

stallation and operational procedures. For assistance 

or additional information consult a qualified installer, 

service agency or the gas supplier.

  WARNING: Any  change  to 

this firebox or its controls can 

be dangerous.

 WARNING: Do not use a 

blower  insert,  heat  exchanger 

insert or other accessory not ap-

proved for use with this firebox.

f i r e - p a r t s . c o m

Summary of Contents for Marquee36

Page 1: ...xplosion may result causing property damage personal injury or loss of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO...

Page 2: ...anufacturer This firebox has been tested under Z21 91b 2007 for use with approved ANSI Z21 11 2 decorativetype unventedroom heater IMPORTANT Read this owner s manualcarefullyandcompletely before tryin...

Page 3: ...urning fireplace Use only decorative unvented room heaters log sets 2 Do not add extra logs or ornaments such as pine cones vermiculite or rock wool Using these added items can cause sooting 3 Use onl...

Page 4: ...EBOX PLANNING Plan where you will install the firebox This will save time and money later when you install the firebox Before installation consider the following 1 Where firebox will be located Allow...

Page 5: ...PECIFICATIONS 36 MODEL Figure 1 36 Model Marquee36 Picture may vary from actual fireplace 30 1 2 29 30 11 1 8 54 1 2 7 7 8 7 36 45 1 8 35 16 97 16 50 365 16 7 3 8 111 8 3 3 4 4 7 8 36 HEARTH 1 1 4 20...

Page 6: ...ATIONS Continued 42 MODEL Figure 2 42 Model Marquee42 Picture may vary from actual fireplace 4 7 8 54 1 2 7 7 8 7 36 5 16 50 42 51 1 8 32 3 8 3 3 4 30 5 16 8 3 4 13 3 5 16 9 7 16 30 11 1 8 42 HEARTH 1...

Page 7: ...CATIONS Continued 50 MODEL Figure 3 50 Model Marquee50 Picture may vary from actual fireplace 365 16 50 8 3 4 13 35 16 97 16 59 1 8 50 7 7 8 7 30 54 1 2 11 1 8 32 3 8 3 3 4 38 5 16 4 7 8 50 HEARTH 1 1...

Page 8: ...ermine if you have a confined or unconfined space Space Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms WA...

Page 9: ...he actual Btu Hr used is more than the maximum Btu Hr the space can support You must provide additional fresh air Your options are as follows A Rework worksheet adding the space of an adjoining room I...

Page 10: ...heaters installed in this firebox create warmaircurrents Thesecurrents move heat to wall surfaces next to firebox Installing firebox next tovinylorclothwallcoveringsor operating firebox where impuri t...

Page 11: ...e built in fire box you must meet the minimum allowable clearance between mantel shelf and top of firebox opening shown in Figure 7 These are the minimum allowable mantel clearances for a safe install...

Page 12: ...2 Install gas piping to firebox location See Gas Line Installation on page 16 and Con necting to Gas Supply in log set owner s manual 3 Carefully set firebox in front of rough opening with back of fi...

Page 13: ...nst a wall in your home The firebox and cabinet mantel can be installed directly on the floor Mantels may be avail able from your retailer or custom built for your home 1 Assemble cabinet mantel as in...

Page 14: ...el Grate retaining bracket should be positioned as shown in Figure A WARNING LIFTING HAZARD SINGLE PERSON LIFT COULD CAUSE INJURY USE ASSISTANCE WHEN MOVING OR LIFTING Figure B Installing Refractory P...

Page 15: ...rear at gas line conduit sleeve if usingaraisedplatform addheight Provide sufficient gas line into fireplace chamber for fitting connection see Figure 16 Note Secure incoming gas line to wood framing...

Page 16: ...tive gas appliance must comply with the Standard for Decorative Gas Appliance for Installation in Solid Fuel Burning Fireplaces ANS Z21 60 or Z21 84 and shall also be installed in accordance with the...

Page 17: ...s a broken component please do not return it to the store Call INNOVATIVE HEARTH PRODUCTS at 1 800 655 2008 to answer questions and replace parts under warranty Note Use only original replacement part...

Page 18: ...www Astria US com 126682 01A 18 PARTS 36 42 AND 50 MODELS 11 10 11 13 14 15 16 14 3 22 20 21 20 1 19 5 14 15 16 13 12 11 9 7 6 8 17 2 12 18 4 fire parts com...

Page 19: ...109457 02 Screen 42 2 109457 01 Screen 50 2 117556 03 Screen 36 Stainless 2 117556 02 Screen 42 Stainless 2 117556 01 Screen 50 Stainless 2 21 20806 Screen Rod 36 2 110146 03 Screen Rod 42 2 110146 0...

Page 20: ...c50M2 Ivory Stacked F0352 Mosaic50M4 Ivory Split Stacked F0353 Mosaic50M3 Red Herringbone Full Stack F0354 Mosaic50M5 Red Herringbone Split Stack F0355 Mosaic50M3 Ivory Herringbone Full Stack F0356 Mo...

Page 21: ...r acts of God b damages caused by abuse negligence misuse or unauthorized alteration or repair of the Product affecting its stability or performance The Product must be subjected to normal use The Pro...

Page 22: ...TY Model located on product or identification tag ______________________________ Serial No located on product or identification tag ___________________________ Date Purchased _________________________...

Page 23: ...NOTES fire parts com...

Page 24: ...126682 01 Rev A 02 14 1508 Elm Hill Pike Suite 108 Nashville TN 37210 1 800 655 2008 www IHP US com P126682 01 fire parts com...

Reviews: