KEY 

NO. PART NO. 

DESCRIPTION

QTY.

1

**

Face Assembly

• • •

1

2

**

Firebox Bottom Assembly

• • •

1

3

**

Firebox Bottom

• • •

1

4

**

Firebox Surround

• • •

1

5

**

Insulation Pan Support

• • •

1

6

**

Insulation Pan

• • •

1

7

**

Top Insulation

• • •

1

8

110454-03

Fireplace Top 36"

1

110454-02

Fireplace Top 42"

1

110454-01

Fireplace Top 50"

1

9

23490SA

Standoff

• • •

4

10

**

Fireplace Surround Assembly

• • •

1

11

109720-02

Clearance Spacer

• • •

6

12

117891-01

Fireplace Handle Bracket

• • •

4

13

20042

Outside Air Cover Plate

• • •

2

14

21171

Gas Conduit Cover

• • •

4

15

109752-01

Conduit One

• • •

2

16

109752-02

Conduit Two

• • •

2

17

**

Heat Shield Support

• • •

1

18

123298-03

Ash Box Assembly

• • •

1

19

**

Firebox Top

• • •

1

20

109457-03

Screen 36"

2

109457-02

Screen 42"

2

109457-01

Screen 50"

2

117556-03

Screen 36" Stainless

2

117556-02

Screen 42" Stainless

2

117556-01

Screen 50" Stainless

2

21

20806

Screen Rod 36"

2

110146-03

Screen Rod 42"

2

110146-02

Screen Rod 50" 

2

117568-03

Screen Rod 36" Stainless

2

117568-02

Screen Rod 42" Stainless

2

117568-01

Screen Rod 50" Stainless

2

22

109511-01

Hood 50"

1

109511-02

Hood 42"

1

109511-03

Hood 36"

1

109511-04

Hood Stainless 36"

1

109511-05

Hood Stainless 42"

1

109511-06

Hood Stainless 50"

1

PARTS AVAILABLE NOT SHOWN

109714-02

Side Firebrick Wall Spacers

• •

4

114913-01

Rear Firebrick Wall Spacers

• •

2

114913-01

Rear Firebrick Wall Spacers

6

** Not a field replaceable part.

36" 42" 50"

PARTS

This  list  contains  replaceable  parts  used  in  your  firebox.  When  ordering  parts,  follow  the 

instructions listed under 

Replacement Parts

 on page 17 of this manual.

f i r e - p a r t s . c o m

Summary of Contents for Marquee36

Page 1: ...xplosion may result causing property damage personal injury or loss of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO...

Page 2: ...anufacturer This firebox has been tested under Z21 91b 2007 for use with approved ANSI Z21 11 2 decorativetype unventedroom heater IMPORTANT Read this owner s manualcarefullyandcompletely before tryin...

Page 3: ...urning fireplace Use only decorative unvented room heaters log sets 2 Do not add extra logs or ornaments such as pine cones vermiculite or rock wool Using these added items can cause sooting 3 Use onl...

Page 4: ...EBOX PLANNING Plan where you will install the firebox This will save time and money later when you install the firebox Before installation consider the following 1 Where firebox will be located Allow...

Page 5: ...PECIFICATIONS 36 MODEL Figure 1 36 Model Marquee36 Picture may vary from actual fireplace 30 1 2 29 30 11 1 8 54 1 2 7 7 8 7 36 45 1 8 35 16 97 16 50 365 16 7 3 8 111 8 3 3 4 4 7 8 36 HEARTH 1 1 4 20...

Page 6: ...ATIONS Continued 42 MODEL Figure 2 42 Model Marquee42 Picture may vary from actual fireplace 4 7 8 54 1 2 7 7 8 7 36 5 16 50 42 51 1 8 32 3 8 3 3 4 30 5 16 8 3 4 13 3 5 16 9 7 16 30 11 1 8 42 HEARTH 1...

Page 7: ...CATIONS Continued 50 MODEL Figure 3 50 Model Marquee50 Picture may vary from actual fireplace 365 16 50 8 3 4 13 35 16 97 16 59 1 8 50 7 7 8 7 30 54 1 2 11 1 8 32 3 8 3 3 4 38 5 16 4 7 8 50 HEARTH 1 1...

Page 8: ...ermine if you have a confined or unconfined space Space Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms WA...

Page 9: ...he actual Btu Hr used is more than the maximum Btu Hr the space can support You must provide additional fresh air Your options are as follows A Rework worksheet adding the space of an adjoining room I...

Page 10: ...heaters installed in this firebox create warmaircurrents Thesecurrents move heat to wall surfaces next to firebox Installing firebox next tovinylorclothwallcoveringsor operating firebox where impuri t...

Page 11: ...e built in fire box you must meet the minimum allowable clearance between mantel shelf and top of firebox opening shown in Figure 7 These are the minimum allowable mantel clearances for a safe install...

Page 12: ...2 Install gas piping to firebox location See Gas Line Installation on page 16 and Con necting to Gas Supply in log set owner s manual 3 Carefully set firebox in front of rough opening with back of fi...

Page 13: ...nst a wall in your home The firebox and cabinet mantel can be installed directly on the floor Mantels may be avail able from your retailer or custom built for your home 1 Assemble cabinet mantel as in...

Page 14: ...el Grate retaining bracket should be positioned as shown in Figure A WARNING LIFTING HAZARD SINGLE PERSON LIFT COULD CAUSE INJURY USE ASSISTANCE WHEN MOVING OR LIFTING Figure B Installing Refractory P...

Page 15: ...rear at gas line conduit sleeve if usingaraisedplatform addheight Provide sufficient gas line into fireplace chamber for fitting connection see Figure 16 Note Secure incoming gas line to wood framing...

Page 16: ...tive gas appliance must comply with the Standard for Decorative Gas Appliance for Installation in Solid Fuel Burning Fireplaces ANS Z21 60 or Z21 84 and shall also be installed in accordance with the...

Page 17: ...s a broken component please do not return it to the store Call INNOVATIVE HEARTH PRODUCTS at 1 800 655 2008 to answer questions and replace parts under warranty Note Use only original replacement part...

Page 18: ...www Astria US com 126682 01A 18 PARTS 36 42 AND 50 MODELS 11 10 11 13 14 15 16 14 3 22 20 21 20 1 19 5 14 15 16 13 12 11 9 7 6 8 17 2 12 18 4 fire parts com...

Page 19: ...109457 02 Screen 42 2 109457 01 Screen 50 2 117556 03 Screen 36 Stainless 2 117556 02 Screen 42 Stainless 2 117556 01 Screen 50 Stainless 2 21 20806 Screen Rod 36 2 110146 03 Screen Rod 42 2 110146 0...

Page 20: ...c50M2 Ivory Stacked F0352 Mosaic50M4 Ivory Split Stacked F0353 Mosaic50M3 Red Herringbone Full Stack F0354 Mosaic50M5 Red Herringbone Split Stack F0355 Mosaic50M3 Ivory Herringbone Full Stack F0356 Mo...

Page 21: ...r acts of God b damages caused by abuse negligence misuse or unauthorized alteration or repair of the Product affecting its stability or performance The Product must be subjected to normal use The Pro...

Page 22: ...TY Model located on product or identification tag ______________________________ Serial No located on product or identification tag ___________________________ Date Purchased _________________________...

Page 23: ...NOTES fire parts com...

Page 24: ...126682 01 Rev A 02 14 1508 Elm Hill Pike Suite 108 Nashville TN 37210 1 800 655 2008 www IHP US com P126682 01 fire parts com...

Reviews: