VENTING INSTALLATION

NOTICE: Read these instructions completely before 

attempting installation.

These models are tested and approved for use with an IHP (direct 

vent) pipe components and terminations.
The venting system must terminate on the outside of the structure and 

can not be attached to a chimney or flue system serving a separate 

solid fuel or gas burning appliance. A direct vent appliance must 

have its own venting system. DO NOT common vent this appliance.
These models are approved to be vented either horizontally through 

an outside wall or vertically through a roof or chase enclosure using 

the following guidelines:

•  When venting system terminates horizontally on an outside wall, 

you may install a standoff if the termination cap is to be installed 

directly on a combustible finish such as vinyl, wood, stucco, etc.

•  Never run the vent downward as this may cause excessive tem

-

peratures which could cause a fire.

•  Vent pipe air space clearances to combustibles are 1" on all sides 

except on the horizontal sections, which requires 2" clearance 

from the top of the pipe. Where the termination cap penetrates a 

combustible wall, 1" air space clearance is required.

•  Have  fireplace  and  selected  vent  components  on  hand  to  help 

determine the exact measurements when elbowing or offsetting. 

Always use wall firestops when penetrating walls and firestops 

when penetrating ceilings or attic spaces.

•  For installation of fireplace at elevations of 4000 feet or greater, 

pay special attention to venting requirement recommendations.

 WARNING: Read all instructions completely and 

thoroughly before attempting installation. Failure to 

do so could result in serious injury, property damage 

or loss of life.

NOTICE: Failure to follow these instructions will void the 

warranty.

NOTICE: Do not seal termination cap to vent pipe. Cap 

must be removable for vent inspection and mainte-

nance.

INSTALLATION PRECAUTIONS

•  Wear gloves and safety glasses for protection
•  Use extreme caution when using ladders or when on roof tops
•  Be aware of electrical wiring locations in walls and ceilings

The following actions will void the warranty on your venting system:

•  Installation of any damaged venting component
•  Unauthorized modification of the venting system (Do not cut or alter 

vent components)

•  Installation of any component part not manufactured or approved 

by IHP

•  Installation other than as instructed by these instructions

 WARNING: This gas fireplace and vent assembly 

must be vented directly to the outside. The venting 

system must NEVER be attached to a chimney serving 

a separate solid fuel burning appliance. Each direct 

vent gas appliance must use a separate vent system. 

Do not use common vent systems.

 WARNING: Vent pipe air space clearances to com-

bustibles are 1" on all sides except on the horizontal 

sections, which require 2" clearances from the top 

of the pipe. Where the termination cap penetrates a 

combustible wall, 1" air space clearance is required.

INSTALLATION PLANNING

There are two basic types of direct vent installation:

•  Horizontal Termination
•  Vertical Termination 

Horizontal Termination Installation

IMPORTANT:

 Horizontal square terminations require only inner por-

tion of wall firestop. Horizontal installations using round termination 

require exterior portion of wall firestop.

1.  Set fireplace in its desired location and determine the route your 

horizontal venting will take. Do not secure fireplace until all vent-

ing has been installed. Some installations require sliding fireplace 

in and out of position to make final venting connections. Figures 

15 and 16 on pages 14 and 15, show different configurations for 

venting with horizontal termination that will help you decide which 

application best suits your installation. Check to see if wall studs 

or roof rafters are in the path of your desired venting route. If they 

are, you may want to adjust location of fireplace.

2.  Direct vent pipe sections and components are designed with 

special twist-lock connections.

 

Twist-Lock Procedure:

 Female ends of pipes have locking lugs 

(indentations). These lugs will slide straight into matching slots 

on male ends of adjacent pipes. Push pipe sections together and 

twist one section clockwise approximately one-quarter turn until 

sections are fully locked (see Figure 9, page 13).

  Note: Horizontal runs of vent must be supported every three feet. 

Use wall straps for this purpose.

3.  Assemble desired combination of pipe and elbows to fireplace flue 

collar. If there are long portions of venting run, pre-assembled 

pipe sections may be installed as subassemblies for convenience.

4.  Carefully determine location where vent pipe assembly will pen-

etrate outside wall. Center of hole should line up with center line 

of horizontal vent pipe. Mark wall for an 11 

1

/

2

" x 11 

1

/

2

" square 

hole. Cut and frame square hole in exterior wall where vent will 

be terminated. If wall being penetrated is constructed of noncom-

bustible material, such as masonry block or concrete, an 8 

1

/

2

hole with zero clearance is acceptable (see Figure 10 page 13).

 WARNING: Do not recess vent termination into any 

wall. This will cause a fire hazard.

Summary of Contents for Devonshire36TEN

Page 1: ...EXPLOSION Le non respect Des avertissements de s curit pourrait d entra ner des blessures graves la mort ou des dom mages mat riels Do not store or use gasoline or other flammable vapors and liquids...

Page 2: ...SAR QUEMADURAS USTED DEBE NUNCA TOCAR EL VIDRIO CALIENTE LOS NI OS DEBEN NUNCA TOCAR EL VIDRIO L cran pare tincelles fourni avec ce foyer r duit le risque de br lure en cas de contact accidentel avec...

Page 3: ...le soient conscients du danger de br lure encouru Les surfaces de votre foyer deviennent EXTR MEMENT CHAUDES La vitre situ e l avant du foyer atteint des temp ratures EXTR MEMENT LEV ES et peut causer...

Page 4: ...ent en contact avec la surface chaude Il est recommand d installer une barri re physique si des personnes risques habitent la maison Pour emp cher l acc s un foyer ou un po le installez une barri re d...

Page 5: ...ested by the PFS Corporation to ANSI Z21 50 CSA 2 22 standard as vented gas fireplace NOTICE Decorative product not for use as a heating appliance This fireplace must be installed by a qualified certi...

Page 6: ...vice person The appliance should be inspected before use and at least annually by a professional service person More frequent cleaning may be re quired due to excessive lint from carpeting bedding mat...

Page 7: ...nstitute Inc 25 West 43rd Street 4th floor New York NY 10036 National Fire Protection Association Inc 1 Batterymarch Park Quincy MA 02169 7471 PRODUCT IDENTIFICATION PRODUCT FEATURES These are a few f...

Page 8: ...utions before deciding the exact location for your fireplace and termination cap When deciding the location of your fireplace follow these rules Do not connect this fireplace venting to a chimney flue...

Page 9: ...40 36 44 42 44 36 48 42 35 36 42 42 41 36 48 42 21 1 8 36 25 1 8 42 Requires IHP 5 I D 8 O D Direct Vent Pipe 11 7 8 36 13 5 8 42 29 1 8 36 34 3 4 42 20 1 2 36 24 42 NAILING FLANGE NAILING FLANGE GAS...

Page 10: ...eplace This will help circulate the heat throughout the house FRAMING AND FINISHING Figures 5 and 5a shows typical framing of this fireplace Figure 6 shows framing for corner installation All minimum...

Page 11: ...S if greater than 50 000 36 91 cm in Canada if greater than 100 000 K clearance to a mechanical air supply inlet In Canada 6 ft 1 83m minimum In US 3 ft 91 cm above if within 10 ft 3 m horizontally L...

Page 12: ...ent assembly must be vented directly to the outside The venting system must NEVER be attached to a chimney serving a separate solid fuel burning appliance Each direct vent gas appliance must use a sep...

Page 13: ...re 12 page 14 Siding standoff must sit flush against exterior fascia material 6 Connecting Vent Cap with Horizontal Vent Pipe Slide wall firestop over vent pipe before connecting horizontal run to ven...

Page 14: ...l minimum and maximum dimensions which MUST be met Figure 16 page 15 shows a configuration for venting with horizontal termination using two 90 elbows with a chart of critical minimum and maximum dime...

Page 15: ...irestop below framed hole Firestop should be installed with no less than three nails per side see Figure 15 page 14 2 Assemble desired lengths of pipe and elbows necessary to reach from fireplace flue...

Page 16: ...above 2000 feet you may need to decrease the input rating by changing the existing burner orifice to a smaller size Reduce input 4 for each 1000 feet above sea level Check with your local gas company...

Page 17: ...re to between 11 and 14 of w c pressure If you do not reduce incoming gas pressure fireplace regulator damage could occur Install external regulator with the vent pointing down as shown in Figure 21 P...

Page 18: ...l gas fireplace or using compressed air 4 Check all joints of gas supply piping system Apply noncorrosive leak detection fluid to all joints Bubbles forming show a leak Correct all leaks at once CONNE...

Page 19: ...LASS DOOR CAUTION Do not operate this fireplace with a bro ken glass door panel or without the glass door panel securely in place For replacement part information see Replacement Parts page 38 CAUTION...

Page 20: ...ce lava rock around base of burner Make sure burner ports are not covered see Figure 30 page 21 4 Place ember flakes around front and sides of burner and on burner ports see Figure 31 page 21 This wil...

Page 21: ...urner Module 3 Carefully lift and remove 3 hearth refractories from fireplace 4 Remove 3 spacers from firebox bottom see Figure 34 5 For 36 models only Remove 3 loose logs from log set see Figures 29...

Page 22: ...terrupteur mural qui contr le le foyer Figure A ou du thermostat mural Figure B Choisissez la langue qui est principalement parl e dans la r sidence du propri taire En cas de doute collez l tiquette e...

Page 23: ...a few hours 1 STOP Read the safety information above 2 Turn off all electric power to fireplace 3 Turn safety shutoff switch to the OFF position 4 Remove center brick control cover 5 Turn equipment s...

Page 24: ...ration Turn blower off by turning knob fully counterclock wise before continuing Figure 36 Blower Assembly Magnet Exhaust Port Ring Connector Ring Connector Ring Connector Screw Screw Speed Control Gr...

Page 25: ...wall switch connected to the two BROWN wires on the module 3 When the remote off is in the REMOTE position the burner will operate from the Remote Control transmitter NOTE The module must be programm...

Page 26: ...a Limpiebienlaplacadelinterruptoroeltermostatode paredparaquitarelpolvoyaceite Peguelaetiqueta enlasuperficiedelaplacadelinterruptorquecontrola la chimenea Figura A o en el termostato de pared Figura...

Page 27: ...ustment screw marked PILOT clockwise to decrease or counterclockwise to increase the flame to proper size see Figure 35 page 23 Do not remove the adjustment screw see Troubleshooting page 29 BURNER FL...

Page 28: ...ION Wear gloves and safety glasses while handling or removing broken glass Do not remove if glass is hot Keep children and pets away from glass If glass has been broken carefully remove glass door see...

Page 29: ...ossible obstructions 4 Contact your gas supplier to check pres sure 5 Have a qualified technician replace pilot line 6 Replace control valve Refer to Replace ment Parts page 35 7 Check that main power...

Page 30: ...blocked 3 Improper venting or excessive blockage 4 Excessive amounts of embers and pan material OBSERVED PROBLEM Gas odor even when gas control valve is off Gas odor during combustion Glass soots Dar...

Page 31: ...41 000 25 000 Btu hr Gas Type Propane LP Gas Only Ignition Electronic Manifold Pressure 10 w c Minimum Inlet Supply Pressure 11 w c Maximum Inlet Supply Pressure 13 w c Front Orifice 54 Rear Orifice...

Page 32: ...555 Devonshire 42 Ng Herr Red Devonshire42TEP F1559 Devonshire 42 Lp Herr Ivory Devonshire42TEP F1563 Devonshire 42 Lp Herr Red Devonshire42TEP F1561 Devonshire 42 Lp Ledgestone Devonshire42TEP F1562...

Page 33: ...tch 2 9 Firebox Leg 4 10 Firebox Bottom 1 11 J7659 Gasket 36 1 J7660 Gasket 42 1 12 J7661 Draft Diverter 1 13 Air Exchange 1 14 5 Gasket 1 15 5 Inner Connector 1 16 A E Insulation 1 17 Firebox Surroun...

Page 34: ...1550 Devonshire 36 Lp Herr Red Devonshire36TEP F1551 Devonshire 36 Lp Ledgestone Devonshire36TEP F1552 Devonshire 36 Lp Std Ivory Devonshire36TEP F1553 Devonshire 36 Lp Stk Red Devonshire42TEN F1557 D...

Page 35: ...ilot Shield 1 9 J7696 Elbow Street 3 8 1 10 J7699 Front Orifice 42 NG 1 J7692 Front Orifice 54 Propane LP 1 J7894 Front Orifice 39 NG 1 J7895 Front Orifice 53 Propane LP 1 11 Base 1 12 J7700 Grommet S...

Page 36: ...in poor performance and safety hazards KEY NO CATALOG NO DESCRIPTION Devonshire42 F1556 Devonshire36 F1546 Devonshire42 F1561 Devonshire36 F1551 QTY 1 J7827 Rear Refractory 42 Ledgestone 1 J7828 Rear...

Page 37: ...Replacement Parts on page 35 of this manual This table uses catalog numbers for clarity on particular models KEY NO CATALOG NO DESCRIPTION Devonshire42 F1555 F1563 Devonshire36 F1555 F1563 Devonshire...

Page 38: ...f the fireplace If you encounter any problems or have any questions concerning the installation or application of this fireplace please contact your dealer IHP 1508 Elm Hill Pike Suite 108 Nashville T...

Page 39: ...riot fire flood or acts of God b damages caused by abuse negligence misuse or unauthorized alteration or repair of the Product affecting its stability or performance The Product must be subjected to n...

Page 40: ...ecolors stylesandproducts Consult your local distributor for fireplace code information Printed in U S A 2014 IHP LLC P N 126730 01 Rev C 11 2015 P126730 01 WARRANTY KEEP THIS WARRANTY 1508 Elm Hill P...

Reviews: