Figure 9 - Lineal Gain

Hemmed 

End

8" Stainless 

Inner Pipe

12 

3

/

8

Galvanized 

Outer Pipe

 WARNING: The opening in collar around chimney 

at top of fireplace must not be obstructed. Never use 

blown insulation to fill chimney enclosure

.

VENTING INSTALLATION 

Continued

ASSEMBLY AND INSTALLATION OF DOUBLE WALL CHIMNEY 

SYSTEM

SS-8DM starter section must be installed first.

Each double wall chimney section consists of a galvanized outer 

pipe, a stainless steel inner flue pipe and a wire spacer. Pipe sections 

must be assembled independently as chimney is installed. When 

connecting chimney directly to fireplace, inner flue pipe section 

must be installed first with lanced side up. Outer pipe section can 

then be installed over flue pipe section with hemmed end up. Press 

down on each pipe section until lances securely engage hem on 

fireplace starter. Wire will assure proper spacing between inner 

and outer pipe sections.

Note:

 For Canada, use chimney parts designated HT.

 Opening in collar around chimney at top of 

fireplace must not be obstructed. Never use blown 

insulation to fill chimney enclosure.

Continue to assemble chimney sections as outlined, making sure 

that both inner and outer pipe sections are locked together. When 

installing double wall snap-lock chimney together, it is important to 

assure joint between chimney sections is locked. Check by pulling 

chimney upward after locking. Chimney will not come apart if properly 

locked. It is not necessary to add screws to keep chimney together 

(exception - see Figure 12, page 10).

USING ELBOW OFFSET 30E-12DMO-8DMR

To clear overhead obstructions, you may offset your chimney system 

using 

30E-12DMO-8DMR 30° Offset/return elbow.

A section or sections of chimney may be used between offsets and 

return elbow. Starter section must be used after elbow offset is at-

tached.

1.  To achieve desired offset, you may install combinations of 12", 

18", 24", 36" and 48" length of double wall pipe (see offset chart).

 

Note:

 For systems with 2 elbow sets, minimum height is 22 feet. 

Maximum height for any system is 50 feet.

2.  Chimney weight above offset rests on return elbow. Straps must 

be securely nailed to rafters or joists (see Figure 11, details A and 

B, page 9).

3.  Maximum length of pipe between supports (return elbow or 12S-

8DM) is 6' of angle run. Maximum of two 6' angle run sections 

per chimney system (see Figure 10, page 9).

4.  All pipe connections between offset and return must be secured 

with two screws on outer pipe only (see Figure 12, page 10). Do 

not penetrate inner stainless.

LINEAL GAIN

PART NO.

DESCRIPTION

GAIN

42"

Fireplace

45"

SS-8DM

Starter Section

19''

12-8DM

12-8HT

Pipe Section

10 

5

/

8

"

18-8DM

18-8HT

Pipe Section

16 

5

/

8

"

24-8DM

24-8HT

Pipe Section

23 

5

/

8

"

36-8DM

36-8HT

Pipe Section

34 

5

/

8

"

48-8DM

48-8HT

Pipe Section

46 

5

/

8

"

RT-8DM

Round Termination

7

/

8

"*

RTL-8DM

Round Termination

3

/

4

"*

RLT-8DM

Round Termination

1

/

2

"*

RTT-8DM

Round Termination 

with Slip Section

7

/

8

" to 

23 

1

/

8

"*

RTTL-8DM Round Termination 

with Slip Section

1

/

2

" to  

21 

1

/

2

"*

RLTT-8DM Round Termination 

with Slip Section

1

/

2

" to  

21 

1

/

4

"*

ET-8DM

Square Chase-Top

12"*

ETO-8DM

Square Chase-Top 

with Mesh

12"*

ETL-8DM

Square Chase-Top 

with Slip Section

7" to 15"*

ETLO-8DM

Square Chase-Top 

with Mesh & Slip 

Section

12" to  

25 

1

/

2

"*

* The lineal gain for the terminations is 

measured to the flue gas outlet height.

Summary of Contents for Craftsman 42P2

Page 1: ...wood burning fireplace or for use with a vented gas log approved to ANS Z21 60 Z21 84 standards or for use with a vent free gas log heater approved to ANS Z21 11 2 standard An INNOVATIVE HEARTH PRODU...

Page 2: ...e voided by and IHP disclaims any respon sibility for the following actions a Modification of the fireplace components doors air inlet system and damper control b Use of any component part not manufac...

Page 3: ...insects and fungus When burned thesechemicalscanposeasignificanthazard WARNING BURNING IMPROPER FUEL I E CHARCOAL CAN RESULT IN CARBON MONOXIDE POISONING WHICH MAY LEAD TO DEATH Carbon Monoxide Poiso...

Page 4: ...TIBLE MATERIAL ON FACE NO COMBUSTIBLE MATERIAL BELOW TOP SPACERS GAS LINE KNOCK OUT AIR KIT KNOCK OUTS GAS LINE STARTER SECTION 8DM PIPE INNER DIA OUTER DIA 15 KNOCK OUTS ELECTRICAL OUTLET LEFT SIDE R...

Page 5: ...ace directly in front of this opening and slide unit back until nailing flanges touch side framing 4 Check level of fireplace and shim with sheet metal if necessary 5 Before securing fireplace to prep...

Page 6: ...ce if projection from front face falls within limits shown in Figure 6 Figure 4 Mantel Clearances to Combustible Material with Louver Figure 5 Mantel Clearances to Combustible Material without Louver...

Page 7: ...ower Source Receptacle Supplied Power Source Wiring Not Supplied Prewired Receptacle and Ground Sheet Metal Screws Figure 8 Outside Air Kit Secure to Collars with Metal Tape Screws or Straps Min of 1...

Page 8: ...ELBOW OFFSET 30E 12DMO 8DMR To clear overhead obstructions you may offset your chimney system using 30E 12DMO 8DMR 30 Offset return elbow A section or sections of chimney may be used between offsets a...

Page 9: ...e Detail B Ceiling Support Pipe 12S 8DM 30E 8DM Return Elbow 30E 8DM Return Elbow 30E 8DM Offset Elbow 30E 8DM Offset Elbow 30E 12DMO 8DMR Offset Elbow 30E 12DMO 8DMR Offset Elbow 30E 12DMO 8DMR Offse...

Page 10: ...with Living Space Above Ceiling If area above is a living space install firestop below framed hole Figure 12 Elbow Offset OFFSET CHART WITH TRANSITION PIPE OFFSET RISE OFFSET RETURN ELBOW TRANSITION...

Page 11: ...Attic Space Above Ceiling If area above is an attic or insulated area install firestop above framed hole IMPORTANT NOTICE When penetrating a ceiling into an attic a firestop thimble 38FST or FST30 is...

Page 12: ...l use only noncombustible mortar or adhesive Storm Collar Installation SC1 Place storm collar over pipe and slide down until it is snug against open edge of flashing see Figure 17 Use SC1 for all roun...

Page 13: ...duit sleeve if using a raised platform add height Provide sufficient gas line into fireplace chamber for fitting OPTIONAL GAS LINE INSTALLATION VENTING INSTALLATION Continued connection see Figure 23...

Page 14: ...ARELEFT PARTLYOPEN GASANDFLAMEMAYBEDRAWNOUT OF THE FIREPLACE OPENING CREATING RISKS OF BOTH FIRE AND SMOKE WARNING Discontinue use of the appliance imme diately if doors are damaged and contact a qual...

Page 15: ...of place while fireplace was in transit These coverplatesmustbekeptintheproperlocationpriortousingthefireplace See Figure 26 For further operating guidelines instructions and warranty informa tion ple...

Page 16: ...tria US com 126662 01D 16 PARTS WOOD BURNING FIREPLACE MODELS Craftsman 42P2 Craftsman 42P3 9 12 25 20 30 17 8 1 5 21 2 34 18 11 14 3 37 13 22 10 6 31 7 38 36 35 28 29 15 27 26 16 16 27 4 32 33 19 23...

Page 17: ...ractory 1 12 See Page 18 Bottom Rear Refractory 1 13 See Page 18 Bottom Front Refractory 1 14 Firebox Support Leg 4 15 106687 02 Damper Can Collar 1 16 107839 01 Screen Rod 2 17 Firebox Top Assembly 1...

Page 18: ...hed Brass BD42P Platinum FAN KIT BK3 30 OFFSET AND RETURN 30E 8DM 30E 8HT 30E 12DMO 8DMR F1908 30E 12HTO 8HTR F2199 HERRINGBONE BRICK LINER WHITE Craftsman 42P3 F0713 F0716 Left 108169 01 Right 108170...

Page 19: ...8DM MESH SQUARE TOP TERMINATION WITH SLIP SECTION ETLO 8DM OUTSIDE AIR KIT FOR FLOOR INSTALLATION AK4F MESH ROUND TOP TERMINATIONS RT 8DM TR 8HT RTL 8DM AND RTL 8HT 1 FIRESTOP SPACER 3600FS 8DM 1 OUTS...

Page 20: ...n design materials specifications pricesandalsotodiscontinuecolors stylesandproducts Consult your local distributor for fireplace code information Printed in U S A 2013 IHP LLC P N 126662 01 Rev D 10...

Reviews: