Astria Fireplaces Monterey F0704 Installation And Operation Instruction Manual Download Page 14

Astria.us.com

126656-01_D

14

OPERATION AND MAINTENANCE GUIDELINES

GLASS DOORS

Cabinet type glass doors are optional with this fireplace. Check with 

your local distributor for availability.
To install glass doors, refer to installation instructions that are in-

cluded with kit. When fireplace is in operation, doors must be fully 

open or fully closed position only or a fire hazard may be created 

(see Figure or 31).
A fireplace equipped with glass doors operates much differently 

than a fireplace with an open front. A fireplace with glass doors has 

a limited amount of air for combustion. Excessive heat within the 

fireplace can result if too large a fire is built or if combustion air gate 

is not completely open.

IMPORTANT: 

The following tips should be used to assure that both 

fireplace and glass door retain their beauty and function properly. 
•  Both the flue damper and glass doors must be fully opened 

before starting a fire. This will provide sufficient combustion 

air and maintain safe temperatures in firebox.

•  The glass must be allowed to warm slowly and evenly. The tem-

pered glass will withstand a gradual temperature rise to 550° F, 

which is more than a normal fire will generate. Such materials 

as pitch/wax laden logs, very dry mill end lumber and large 

amounts of paper or cardboard boxes. Always keep the fire well 

back from the doors and never allow flames to contact the glass.

  WARNING: FIREPLACES EQUIPPED WITH DOORS 

SHOULD BE OPERATED ONLY WITH DOORS FULLY 

OPEN OR DOORS FULLY CLOSED. IF DOORS ARE LEFT 

PARTLY OPEN, GAS AND FLAME MAY BE DRAWN OUT 

OF THE FIREPLACE OPENING, CREATING RISKS OF 

BOTH FIRE AND SMOKE.

  WARNING: Discontinue use of the appliance 

immediately if doors are damaged and contact a 

qualified installer for repair. Only doors certified 

with the appliance shall be used.

 WARNING: Do not slam or strike doors. Damage 

can result in a hazardous condition.

Figure 31 - Cabinet Glass Doors

Cleaning Glass

Clean glass with any commercial glass cleaner or soap and water. 

Do not use any abrasive material to clean glass. Do not clean glass 

with any cool water if glass is still hot from the fire. To remove doors, 

refer to instructions included with glass door kit.

DAMPER MECHANISM

The damper control lever is located inside the fire chamber (see Fig-

ure 32). Make sure lever is cool before handling. Pull down to close 

and push up to open. Damper must be open when lighting a fire. 

Not doing so will cause smoke spillage into the room. When firebox 

is not in use, close damper to prevent down drafts to enter room.

GRATE

OUTSIDE AIR
HANDLE
PULL TO CLOSE
PUSH TO OPEN

DAMPER CONTROL LEVER
PULL DOWN TO CLOSE
PUSH UP TO OPEN

Figure 32 - Damper Operation

OUTSIDE AIR MECHANISM

The outside air handle is located at the right hand side of firebox 

rear refractory (see Figure 32). Pull to close, push to open. Always 

open mechanism when starting a fire. This provides adequate outside 

combustion air. Close mechanism when not in use to prevent cold 

air from entering room. Periodically check your outside air intake 

vent hood for any possible obstructions such as snow, bushes, etc.

Glass Doors Must be Fully Open (as Shown) 

or Fully Closed when Appliance is in Operation

Summary of Contents for Monterey F0704

Page 1: ...led when using a vent free log heater see Ac cessories page 17 FOR CANADA The authority having jurisdiction such as the municipal building department fire department etc should be contacted before installation to determine the need to obtain a permit POUR LE CANADA L autorité compétente comme le service municipal du bâtiment les pompiers etc doit être contacté avant l installation afin de détermin...

Page 2: ...n sibility for the following actions a Modification of the fireplace or any of the components manu factured by IHP unless otherwise permitted by IHP b Use of any component part not manufactured or approved by IHP in combination with an IHP fireplace system c Installation and or operation in a manner other than instructed in this manual d The burning of any other fuel not tested or approved by IHP ...

Page 3: ...oodorwoodsthathavebeendippedintar pitch pine tar creosote etc Wood products made with synthetic binders such as plywood produce ab normally high temperatures and sputtering smoking fires When burning artificial logs please read and follow the instructions provided by the manufacturer Never burn treated construction lumber or scraps These woods burn excessively hot and may contain chemicals used to...

Page 4: ...ire SAFETY Continued Figure 1 Dimensions WARNING Always leave glass doors fully opened or fully closed when operating fireplace WARNING Children and adults should be alerted to the hazards of high surface temperatures and to stay away to avoid burns or clothing ignition Young children should be carefully supervised when in the same room as fireplace MODEL CATALOG NO Monterey PFP2 F0704 29 1 2 750 ...

Page 5: ...ther flam mable liquids may be stored The firebox area must be kept clear and free from these combustible materials The typical installation for this fireplace is a projected installation which allows you to extend the fireplace any distance into the room A projection may be ideal for a new addition on an existing finished wall Figure 3 Firebox Clearances Figure 2 Common Location of Fireplace MINI...

Page 6: ...ming Firebox with Z Type Ember Protectors Figure 7 Ember Protectors Figure 8 Nailing Flanges HEARTH EXTENSIONS A hearth extension projecting a minimum of 20 in front of and a minimum of 12 beyond each side of fireplace opening is required to protect combustible floor construction in front of fireplace see Figure 9 Fabricate a hearth extension using a material which meets the following specificatio...

Page 7: ...2 from effective opening of the firebox NFPA 211 Section Clearance from Combustible Material Mantels or any other combustible material may also come up to the side edge of the black metal face of the firebox only if the projection from the front face falls within limits shown in Figure 12 Figure 12 Mantel Clearances to Metal Face Figure 11 Mantel Clearances to Combustible Materials CHIMNEY PIPE WA...

Page 8: ...or joists see Figure 15 To achieve desired offset you may install combinations of 12 18 36 and 48 length of double wall pipe see offset chart and Figure 16 Maximum length of pipe between supports is 6 feet of angled run A maximum of two 6 feet angled run sections per chimney system see Figure 18 SUPPORT SECTIONS The chimney support section is a 4 strap 12 length of pipe The height of a vertical ch...

Page 9: ...required to avoid intrusion by in sulation and recommended to negotiate a joist see Figure 20a Figure 18 Typical Offset Installations Figure 21 10 Foot Rule 6 Ft 183 cm Max 6 Ft 183 cm Max 6 Ft 183 cm Max 6 Ft 183 cm Max 6 Ft 183 cm Max 6 Ft 183 cm Max Figure 19 Firestop Spacer with Living Space Above Ceiling Figure 20 Firestop Spacer with Attic Space Above Ceiling Existing Ceiling Frame Firestop ...

Page 10: ...f drops 6 for each 12 one measure horizontally down from roof rafters 3 Use roof opening chart Figure 23 to determine correct opening length and flashing required 4 Remove shingles around opening measured Cut out this section 5 Addnextsectionsofpipeuntilendpenetratesroofline Checktosee that proper clearances are maintained Extend chimney by adding sections of double wall pipe until pipe is minimum...

Page 11: ...n being used Figure 24 Flashing Installation Figure 25 Storm Collar CHASE INSTALLATIONS Instructions for chase installations are included with the chase style termination chosen In a multiple chase installation be sure to provide adequate distance between terminations to prevent smoke spillage from one termination to another Terminations must be separated a minimum of 24 center to center and stack...

Page 12: ...ble material may be used for facing glass tile brick etc as long as proper clearances are adhered to and fireplace openings are not obstructed in any way see Minimum Clearance to Combustibles page 5 and Figure 28 Use only heat resistant noncombustible mortar or adhesive when securing facing material to front of fireplace When placing facing at upper edge of effective opening of fireplace provide L...

Page 13: ...gas line and refractory knockout hole with refractory cement or commercial furnace cement Install the gas appliance or cap off gas line if desired CAUTION All gas piping and connections must be tested for leaks after installation is completed After ensuring that gas valve is on apply soap and water solutiontoallconnectionsandjoints Bubblesforming show a leak Correct all leaks at once DO NOT USE AN...

Page 14: ...OORSFULLYCLOSED IFDOORSARELEFT PARTLYOPEN GASANDFLAMEMAYBEDRAWNOUT OF THE FIREPLACE OPENING CREATING RISKS OF BOTH FIRE AND SMOKE WARNING Discontinue use of the appliance immediately if doors are damaged and contact a qualified installer for repair Only doors certified with the appliance shall be used WARNING Do not slam or strike doors Damage can result in a hazardous condition Figure 31 Cabinet ...

Page 15: ...ld be carefully supervised when they are in the same room as fireplace OPERATION AND MAINTENANCE GUIDELINES Continued REPLACEMENT PARTS See Page 16 Fireplace Accessories section for replacement parts Use only parts supplied from the manufacturer Normally all parts should be ordered through your IHP distributor or dealer Parts will be shipped at prevailing prices at time of order When ordering repa...

Page 16: ...et Door 2 sides end panel Platinum Finish J0453 DGPN36 36 Peninsula Wood burning Cabinet Door 2 sides end panel Brushed Finish DOUBLE WALL PIPE F0932 12 12DM 12 Section Double Wall Pipe Snap Lock F0933 18 12DM 18 Section Double Wall Pipe Snap Lock F0934 24 12DM 24 Section Double Wall Pipe Snap Lock F0935 36 12DM 36 Section Double Wall Pipe Snap Lock F0936 48 12DM 48 Section Double Wall Pipe Snap L...

Page 17: ...d when installing a vent free gas log in this fireplace F1764 GA6050 Black Fireplace Hood FIRESTOP THIMBLE F0944 FST10 Firestop Thimble HIGHT TEMPERATURE TOUCH UP PAINT Not Shown J3943 Kit Touch Up paint LABEL UL127 50PK WARNING HOT Fire Risk Insulation and combustibles must not touch pipe Consult manual for clearance requirements Ensure proper connection WARNING HOT Fire Risk Insulation and combu...

Page 18: ...mney Support F0960 RLT 12HT Round Top w Louvers F0961 AP 12HT Anchor Plate Collar Assembly Masonry Fireplaces F0951 CAK 12 Cold Air Collar Kit When ordered alone this part cannot ship via parcel delivery services IMPORTANT NOTICE A manufactured shroud which has been approved by a national testing agency for use with this fireplace may be used if installed in accordance with the instruc tions by it...

Page 19: ...ing the proper venting system for your installation American National Standards Institute ANSI NFPA 211 Standard for Chimneys Fireplaces Vents and Solid Fuel Burning Appli ances See Draft Section A chimney or vent shall be so designed and constructed to develop a flow sufficient to completely remove all flue and vent gases to the outside atmosphere The venting system shall satisfy the draft requir...

Page 20: ...The best location to install your appliance is determined by consid ering the location of windows doors and the traffic flow in the room where the appliance is located allowing space in front of the unit for the hearth extension and the mantel and taking into consideration the location of the hot air ducts some models outside air kit and chimney Ifpossible youshouldchoosealocationwherethechimneywi...

Page 21: ..._____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ________________________________________...

Page 22: ..._____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ________________________________________...

Page 23: ...or propane gas Fuel products with abnormal burning characteristics including but not limited to fuel such as driftwood coal or plywood and wood products using a binder may burn at excessive temperatures and may cause damage to the Product or may cause it to function improperly c damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with th...

Page 24: ...01 Innovative Hearth Products reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information Printed in U S A 2014 Innovative Hearth Products LLC P N 126656 01 Rev D 02 2018 1769 East Lawrence Street Russellville AL 35654 ...

Reviews: