VENTING INSTALLATION 

Continued

MINIMUM/MAXIMUM CHIMNEY HEIGHT

The minimum height of the chimney (measured from the base of the 

fireplace to the flue gas outlet-end of pipe) is 16 feet for a straight run, 

16 feet minimum for a run with 1 elbow set and 25 feet minimum for 

a run with 2 elbow sets. (A set consists of one starter elbow and one 

return elbow.)
Uncommon circumstances such as neighboring hills, tall trees, or 

strong wind areas can cause down drafts in chimney system. In such 

cases, going beyond the minimum recommended height would be 

preferable to provide a better draw.
The fireplace height approved for any chimney run with this fireplace 

system is 40 feet measured from bottom of firebox to flue outlet-end 

of pipe (see Figure 22).

 WARNING: Do not operate an unvented gas log 

set in this fireplace with the chimney removed.

PENETRATING ROOF

To maintain a 2" clearance to pipe on a roof with a pitch, a rectangular 

opening must be cut.
1.  Determine center point where pipe will penetrate the roof.
2.  Determine center point of the roof. Pitch is the distance the roof 

drops over a given span, usually 12". A 6/12 pitch means that the 

roof drops 6" for each 12" one measure horizontally down from 

roof rafters.

3.  Use roof opening chart (Figure 23) to determine correct opening 

length and flashing required.

4.  Remove shingles around opening measured. Cut out this section.
5.  Add next sections of pipe until end penetrates roof line. Check to see 

that proper clearances are maintained. Extend chimney by adding 

sections of double wall pipe until pipe is minimum of 30" above 

highest point of roof cutout. Termination and chimney must extend 

a minimum of 36" above highest point where it passes through the 

roof (see 10-Foot Rule and Figure 21, page 9.

Figure 22 - Maximum Chimney Height

Figure 23 - Roof Opening Measurements

FLASHING INSTALLATION

Determine flashing to be used with roof opening chart. Slide flashing 

over pipe until base is flat against roof. Replace as many shingles as 

needed to cover exposed area and flashing base. Secure in position 

by nailing through shingles (see Figure 24). 

DO NOT NAIL THROUGH 

FLASHING CONE

.

Pitch

Slope Opening "A" 

Max. 

Used Flashing

Model No. 

Flat

19"

V6F-10DM

0-6/12 26.6°

23.25"

V6F-10DM

6/12-

12/12

45°

30.75"

V12F-10DM

Opening

“A”

19" Min.

(48.26cm)

30" Min.

(76.2cm)

2" Min.

(5.08cm)

2" Min.

(5.08cm)

2" Min.

(5.08cm)

Maximum

Height

Chase

Termination

50 Ft.

Minimum

Height

15 Ft.

Storm 

Collar

Flashing

Firestop 

Spacer

Minimum 

Height 15 Ft. 

(4.58 m)

Maximum 

Height Chase 

Termination 

50 Ft.

(15.24 m)

RLT-12D

RLT-12D

STL-12D

Summary of Contents for Monterey F0704

Page 1: ...led when using a vent free log heater see Ac cessories page 17 FOR CANADA The authority having jurisdiction such as the municipal building department fire department etc should be contacted before installation to determine the need to obtain a permit POUR LE CANADA L autorité compétente comme le service municipal du bâtiment les pompiers etc doit être contacté avant l installation afin de détermin...

Page 2: ...n sibility for the following actions a Modification of the fireplace or any of the components manu factured by IHP unless otherwise permitted by IHP b Use of any component part not manufactured or approved by IHP in combination with an IHP fireplace system c Installation and or operation in a manner other than instructed in this manual d The burning of any other fuel not tested or approved by IHP ...

Page 3: ...oodorwoodsthathavebeendippedintar pitch pine tar creosote etc Wood products made with synthetic binders such as plywood produce ab normally high temperatures and sputtering smoking fires When burning artificial logs please read and follow the instructions provided by the manufacturer Never burn treated construction lumber or scraps These woods burn excessively hot and may contain chemicals used to...

Page 4: ...ire SAFETY Continued Figure 1 Dimensions WARNING Always leave glass doors fully opened or fully closed when operating fireplace WARNING Children and adults should be alerted to the hazards of high surface temperatures and to stay away to avoid burns or clothing ignition Young children should be carefully supervised when in the same room as fireplace MODEL CATALOG NO Monterey PFP2 F0704 29 1 2 750 ...

Page 5: ...ther flam mable liquids may be stored The firebox area must be kept clear and free from these combustible materials The typical installation for this fireplace is a projected installation which allows you to extend the fireplace any distance into the room A projection may be ideal for a new addition on an existing finished wall Figure 3 Firebox Clearances Figure 2 Common Location of Fireplace MINI...

Page 6: ...ming Firebox with Z Type Ember Protectors Figure 7 Ember Protectors Figure 8 Nailing Flanges HEARTH EXTENSIONS A hearth extension projecting a minimum of 20 in front of and a minimum of 12 beyond each side of fireplace opening is required to protect combustible floor construction in front of fireplace see Figure 9 Fabricate a hearth extension using a material which meets the following specificatio...

Page 7: ...2 from effective opening of the firebox NFPA 211 Section Clearance from Combustible Material Mantels or any other combustible material may also come up to the side edge of the black metal face of the firebox only if the projection from the front face falls within limits shown in Figure 12 Figure 12 Mantel Clearances to Metal Face Figure 11 Mantel Clearances to Combustible Materials CHIMNEY PIPE WA...

Page 8: ...or joists see Figure 15 To achieve desired offset you may install combinations of 12 18 36 and 48 length of double wall pipe see offset chart and Figure 16 Maximum length of pipe between supports is 6 feet of angled run A maximum of two 6 feet angled run sections per chimney system see Figure 18 SUPPORT SECTIONS The chimney support section is a 4 strap 12 length of pipe The height of a vertical ch...

Page 9: ...required to avoid intrusion by in sulation and recommended to negotiate a joist see Figure 20a Figure 18 Typical Offset Installations Figure 21 10 Foot Rule 6 Ft 183 cm Max 6 Ft 183 cm Max 6 Ft 183 cm Max 6 Ft 183 cm Max 6 Ft 183 cm Max 6 Ft 183 cm Max Figure 19 Firestop Spacer with Living Space Above Ceiling Figure 20 Firestop Spacer with Attic Space Above Ceiling Existing Ceiling Frame Firestop ...

Page 10: ...f drops 6 for each 12 one measure horizontally down from roof rafters 3 Use roof opening chart Figure 23 to determine correct opening length and flashing required 4 Remove shingles around opening measured Cut out this section 5 Addnextsectionsofpipeuntilendpenetratesroofline Checktosee that proper clearances are maintained Extend chimney by adding sections of double wall pipe until pipe is minimum...

Page 11: ...n being used Figure 24 Flashing Installation Figure 25 Storm Collar CHASE INSTALLATIONS Instructions for chase installations are included with the chase style termination chosen In a multiple chase installation be sure to provide adequate distance between terminations to prevent smoke spillage from one termination to another Terminations must be separated a minimum of 24 center to center and stack...

Page 12: ...ble material may be used for facing glass tile brick etc as long as proper clearances are adhered to and fireplace openings are not obstructed in any way see Minimum Clearance to Combustibles page 5 and Figure 28 Use only heat resistant noncombustible mortar or adhesive when securing facing material to front of fireplace When placing facing at upper edge of effective opening of fireplace provide L...

Page 13: ...gas line and refractory knockout hole with refractory cement or commercial furnace cement Install the gas appliance or cap off gas line if desired CAUTION All gas piping and connections must be tested for leaks after installation is completed After ensuring that gas valve is on apply soap and water solutiontoallconnectionsandjoints Bubblesforming show a leak Correct all leaks at once DO NOT USE AN...

Page 14: ...OORSFULLYCLOSED IFDOORSARELEFT PARTLYOPEN GASANDFLAMEMAYBEDRAWNOUT OF THE FIREPLACE OPENING CREATING RISKS OF BOTH FIRE AND SMOKE WARNING Discontinue use of the appliance immediately if doors are damaged and contact a qualified installer for repair Only doors certified with the appliance shall be used WARNING Do not slam or strike doors Damage can result in a hazardous condition Figure 31 Cabinet ...

Page 15: ...ld be carefully supervised when they are in the same room as fireplace OPERATION AND MAINTENANCE GUIDELINES Continued REPLACEMENT PARTS See Page 16 Fireplace Accessories section for replacement parts Use only parts supplied from the manufacturer Normally all parts should be ordered through your IHP distributor or dealer Parts will be shipped at prevailing prices at time of order When ordering repa...

Page 16: ...et Door 2 sides end panel Platinum Finish J0453 DGPN36 36 Peninsula Wood burning Cabinet Door 2 sides end panel Brushed Finish DOUBLE WALL PIPE F0932 12 12DM 12 Section Double Wall Pipe Snap Lock F0933 18 12DM 18 Section Double Wall Pipe Snap Lock F0934 24 12DM 24 Section Double Wall Pipe Snap Lock F0935 36 12DM 36 Section Double Wall Pipe Snap Lock F0936 48 12DM 48 Section Double Wall Pipe Snap L...

Page 17: ...d when installing a vent free gas log in this fireplace F1764 GA6050 Black Fireplace Hood FIRESTOP THIMBLE F0944 FST10 Firestop Thimble HIGHT TEMPERATURE TOUCH UP PAINT Not Shown J3943 Kit Touch Up paint LABEL UL127 50PK WARNING HOT Fire Risk Insulation and combustibles must not touch pipe Consult manual for clearance requirements Ensure proper connection WARNING HOT Fire Risk Insulation and combu...

Page 18: ...mney Support F0960 RLT 12HT Round Top w Louvers F0961 AP 12HT Anchor Plate Collar Assembly Masonry Fireplaces F0951 CAK 12 Cold Air Collar Kit When ordered alone this part cannot ship via parcel delivery services IMPORTANT NOTICE A manufactured shroud which has been approved by a national testing agency for use with this fireplace may be used if installed in accordance with the instruc tions by it...

Page 19: ...ing the proper venting system for your installation American National Standards Institute ANSI NFPA 211 Standard for Chimneys Fireplaces Vents and Solid Fuel Burning Appli ances See Draft Section A chimney or vent shall be so designed and constructed to develop a flow sufficient to completely remove all flue and vent gases to the outside atmosphere The venting system shall satisfy the draft requir...

Page 20: ...The best location to install your appliance is determined by consid ering the location of windows doors and the traffic flow in the room where the appliance is located allowing space in front of the unit for the hearth extension and the mantel and taking into consideration the location of the hot air ducts some models outside air kit and chimney Ifpossible youshouldchoosealocationwherethechimneywi...

Page 21: ..._____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ________________________________________...

Page 22: ..._____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ________________________________________...

Page 23: ...or propane gas Fuel products with abnormal burning characteristics including but not limited to fuel such as driftwood coal or plywood and wood products using a binder may burn at excessive temperatures and may cause damage to the Product or may cause it to function improperly c damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with th...

Page 24: ...01 Innovative Hearth Products reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information Printed in U S A 2014 Innovative Hearth Products LLC P N 126656 01 Rev D 02 2018 1769 East Lawrence Street Russellville AL 35654 ...

Reviews: