SPECIFICATIONS
MAGNIFLAME24MP
MAGNIFLAME24VP
MAGNIFLAME30MP
MAGNIFLAME30VP
• Rating (Variable): 29,000/40,000 Btu/Hr
• Type Gas: Propane/LP
• Ignition: Electronic
• Manifold Pressure: 7.9" W.C.
• Inlet Gas Pressure (in. of water):
Max - 14" W.C., Min* - 11" W.C.
*For purpose of input adjustment
MAGNIFLAME24MN
MAGNIFLAME24VN
MAGNIFLAME30MN
MAGNIFLAME30VN
• Rating (Variable): 29,000/40,000 Btu/Hr
• Type Gas: Natural
• Ignition: Electronic
• Manifold Pressure: 3.4" W.C.
• Inlet Gas Pressure (in. of water):
Max - 10.5" W.C., Min* - 5" W.C.
*For purpose of input adjustment
To Thermopile
To AUTO Terminal
on Switch
To OFF Terminal
on Switch
WIRING DIAGRAM (REMOTE READY MODELS)
WIRING DIAGRAM (VARIABLE CONTROL MODELS)
Black Connectors
Receiver
To Thermopile
White
Red
NOTE
: For proper operation of remote control, wires from thermopile to control receiver must
be connected exactly as shown.
CAUTION: Label all wires prior to disconnection when servicing controls. Wir-
ing errors can cause improper and dangerous operation. Verify proper operation
after servicing.
f i r e - p a r t s . c o m